manualshive.com logo in svg
background image

Operation manual

R32 Split series

English

Operation manual

R32 Split series

FTXP20N5V1B9
FTXP25N5V1B9
FTXP35N5V1B9

ATXP20N5V1B9
ATXP25N5V1B9
ATXP35N5V1B9

Содержание FTXP20N5V1B9

Страница 1: ...Operation manual R32 Split series English Operation manual R32 Split series FTXP20N5V1B9 FTXP25N5V1B9 FTXP35N5V1B9 ATXP20N5V1B9 ATXP25N5V1B9 ATXP35N5V1B9...

Страница 2: ...1 2 Symptom A blowing sound is heard 13 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is heard 14...

Страница 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteri...

Страница 4: ...ecified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock...

Страница 5: ...peration mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control a...

Страница 6: ...anges Long beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a p...

Страница 7: ...a room to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT cont...

Страница 8: ...ystem automatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow oper...

Страница 9: ...temperature setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want...

Страница 10: ...LED then wireless LAN is blinks blinks not connected If operation LED and timer LED then wireless LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS...

Страница 11: ...alculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer for more information NOTICE Maintenance MUST be done by an author...

Страница 12: ...stains use water or a neutral detergent 7 4 To clean the air filters 1 Push the tab at the centre of each air filter then pull it down 2 Pull out the air filters 1 2 3 Remove the titanium apatite deo...

Страница 13: ...ARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fire Contact your de...

Страница 14: ...wireless remote control If the unit runs into a problem you can identify the fault by checking the error code by the wireless remote control It is important to understand the problem and take measures...

Страница 15: ...7028 5D 2023 08 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units M...

Страница 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 5D 2023 08 Copyright 20...

Отзывы: