Installation instructions

Because the compressor is located on the 
controls side of the unit (right side), this side
will be heavier and more awkward to manipulate.
Inadequate support on control side of the unit
can result in personal injury and damage to your
unit and property.  Therefore, it is recommended 
to have someone assist you during the installation
of this unit.

E. Be certain the proper electrical outlet is within reach
of the installation.  Use only a single outlet circuit rated
at  proper current (see table 1 on page 4).  All wiring 
should be in accordance with local and national 
electrical codes.

F. Your unit was designed to evaporate condensation 
under normal conditions.  However, under extreme 
humidity conditions, excess condensation may cause 
the basepan to overflow to the outside.
The unit should be installed where condensation
run-off cannot drip on pedestrians or neighboring
properties.

1. Select the Best Location

A. Your room air conditioner was designed to 
fit easily into a single or double hung window.  However,
since window designs vary, it may be necessary to 
make some modifications for safe and proper
installation.

B. Make sure window and frame is structurally
sound and free from dry and rotted wood.

C. For maximum efficiency, install the air conditioner
on side of the house or building which favors more 
shade than sunlight.  If the unit is in direct sunlight, 
it is advisable to provide an awning over the unit.

D. Provide sufficient clearance around the cabinet
to allow for ample air circulation through the unit.
See

 (Fig.B)

.  The rear of the unit should be outdoors

and not in a garage nor inside of a building.
Keep unit as far away as possible from obstacles and
obstructions and at least 30" above the floor or 
ground.  Curtains and other objects within a room
should be prevented from blocking the air flow.

Awning

Window opening requirements

(see table below)

Side
obstruction

Ground

Fence,
wall, or
other
obstacle.

12" Min.

30" Min.

20" 
Min.

20" 
Min.

CAUTION

!

!

Fig.B

Model

8K-10K

24

"

    

38"    

41"    

27

"

  

22.8" *15.7" *24.1"  

12K 

Size

Cabinet size
   (W*H*D) 
Min. Window
 opening  
Max. Window
 opening

15-24K 

26.5" *18.5" *26.9"   

44"     

30"   

20.5" *14.8" *23.1"  

Содержание SAW24CR3FHUE

Страница 1: ...User s Manual 24 000 BTU Room Air Conditioner SAW24CR3FHUE PTT042106...

Страница 2: ...Contents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6...

Страница 3: ...before starting This manual contains information for the installation and operation of your room air conditioner Note The figures in this manual are based on the external view of a standard model Cons...

Страница 4: ...the air conditioner you have selected Introduction Control Panel Part Identification Remote control model Cabinet Exterior Air Inlet Air Outlet Fresh Air Vent Lever Control Panel Power Cord Front Pane...

Страница 5: ...to use the correct power supply according to the rating plate of your air conditioner 125 8K 15K 22K 24K Table 1 15 15 If the air conditioner has a serial plate rating of 115 volts and up to and incl...

Страница 6: ...ling setting To avoid installation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check...

Страница 7: ...designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe and proper installation B Make sure window and fra...

Страница 8: ...er 1 4 screw For 8K to 12K models Channel 1 4 Screw Fig 3 Fig 4 Installation instructions 3 Assembly of the upper lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal to...

Страница 9: ...3 4 screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3 16 Maximum B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in each brack...

Страница 10: ...Shutters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the ca...

Страница 11: ...moval may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations...

Страница 12: ...air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting t...

Страница 13: ...e below 32 the Temperature display L0 Room Temperature above 99 the Temperature display H1 NOTE Temperature setting range is from 19 66 to 31 88 Fan Speed button Used to select fan speed in sequence a...

Страница 14: ...ct the Auto mode fan speed 9 Saver BUTTON Used to select the mode Energy saving The Above symbols are shown when the relevant mode is in use High fan speed Medium fan speed Low fan speed Auto fan spee...

Страница 15: ...ignal receptor of indoor unit The remote control is NOT preset as Cooling only or Heat Pump by manufacturer Each time after the remote control replaces batteries or is energized the Cooling indicator...

Страница 16: ...front grille To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air cond...

Страница 17: ...ngle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexible tubi...

Страница 18: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Отзывы: