background image

For your personal safety, this portable air conditioner must be grounded. The portable air conditioner is
equipped with a power supply cord with a 3-prong grounding plug. To minimize possible electrical shock
hazard, the cord must be plugged into a mating 3-prong grounding type outlet, grounded in accordance
with all local codes and ordinances. If a mating 3-prong type outlet is not available, it is the consumer's
responsibility to have a properly grounded, 3-prong outlet installed by a licensed installer.

It is the customer's responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code,
ANSI/NFPA 70 – latest edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from:

National Fire Protection Association
Batterymatch Park
Quincy, Massachusetts 02269. 
Or your state board of electricity.

1.6  RECOMMENDED GROUNDING METHOD

SECTION 1      IMPORTANT SAFETY INSTRUCTIONS

5

A Leakage-Current Detect and Interrupt (LCDI) is a device that senses leakage current flowing between or
fom the power conductors in an appliance cord and interrupts the circuit as a predetermined level of leakage
current. Since an LCDI specifically can detect a current leakage flowing to ground, it provides ground fault
protection from arcing and other problems, which arise due to leakage between conductors.

LCDIs are covered under the UL 1699 standard for ARC Fault Current Interrupts, which was first published in
June of 2002. LCDI devices have been mandated by the National Electric Code and Underwritten Laboratories
for the cordsets on room air conditioners beginning in August 2004. Other classes of appliances will require
LCDI protection in the near future.

TESTING

1. Press test button, unit should trip.
2. Press reset button for use.

NOTE: DO NOT USE IF ABOVE TEST FAILS.

In the event this device trips, the cause of the malfunction is to be corrected before use of the device.

CAUTION

The conductors inside this cord are surrounded by shields, which monitor leakage current. THESE SHIELDS ARE
NOT GROUNDED. Periodically examine the cord for any damage. DO NOT USE this product in the event the
shields become exposed.

WARNING

This product contains chemicals, including lead, known to the State of California to cause cancer, and birth
defects or other reproductive harm.
Wash hands after handling.

1.7 LCDI PLUG TECHNOLOGY (US ONLY)

Содержание KY-25

Страница 1: ...USER MANU AL GUIDE GUIDE D UTILISATION MODO DE EMPLEO 9 000BTU 9 000BTU Model KY 25 Y 9000 BTU PORTABLE DIGITAL AIR CONDITIONER WHITE METAL METAL BLANC METAL BLANCO Model KY 25 Y 9000 BTU PORTABLE DI...

Страница 2: ...9 SECTION 4 INSTALLATION INSTRUCTIONS 4 1 PORTABLE AIR CONDITIONER INSTALLATION 10 4 2 ASSEMBLING THE AIR EXHAUST DUCT 10 4 3 INSTALLING THE DUCTS IN THE WALL 11 SECTION 5 OPERATING YOUR PORTABLE AIR...

Страница 3: ...air conditioner follow these basic precautions Plug into an exclusive grounded 3 prong outlet Do not remove ground prong Do not use an adapter Use two or more people to move or install portable air co...

Страница 4: ...nit is supported by four castors In the event of fire use Carbon Dioxide CO2 extinguishers Do not use water or powder extinguishers Please help us to help you This portable air conditioner has been de...

Страница 5: ...lure to follow these instructions can result in death fire or electrical shock In the U S only If codes permit and a separate ground wire is used it is mandatory that the ground path is adequate Check...

Страница 6: ...wer conductors in an appliance cord and interrupts the circuit as a predetermined level of leakage current Since an LCDI specifically can detect a current leakage flowing to ground it provides ground...

Страница 7: ...ust duct for condenser side according to the installation instructions 1 8 UNPACKING YOUR PRODUCT PARTS Keep upright Figure 2 1 9 TECHNICAL SPECIFICATIONS Model Color Rate Cooling Capacity Voltage Fre...

Страница 8: ...number You can find this information on the model and serial number label Please record the model and serial number information below Also record the purchase date of your appliance Model Number Seria...

Страница 9: ...LS NEEDED 3 2 ACCESSORIES 1 Flat blade and Phillips screwdrivers 2 Gloves 3 Tape measure 4 Utility knife 8 Figure 5 1 Indoor terminal end 2 Exhaust duct 3 Window assembly kit 4 Main piece 5 Window kit...

Страница 10: ...not handle with damp or wet hands Do not squeeze the cable or let it come into contact with a sharp surface Do not use the power cables to drag the unit Do not leave the cable in a tangled coil when i...

Страница 11: ...nels if necessary Cut the window piece as needed to fit the length of your window or sliding door Make sure that the hole on the main piece is not covered by other pieces F Place the window kit in the...

Страница 12: ...commended that you use the shortest possible length of hose Take care to prevent any kind of bend in the middle of the exhaust hose as this will trap hot exhaust air which will radiate back into the r...

Страница 13: ...the fan speed High speed or Low speed 4 Up or Down Temperature or Time Changing Button Use these two buttons to set to your desired temperature The temperature unit can be on Fahrenheit or Centigrade...

Страница 14: ...ments When the unit is OFF if it hasn t been set on Time Delay press the Timer button The unit enters Timer Program Also the will flash in Timer Set Display Window and the Timer Indicator will be on i...

Страница 15: ...to your desired room temperature with the temperature ranges from 64 F 90 F 18 C 32 C Recommended temperatures are 80 F 84 F 27 C 29 C 5 Select the fan speed by pressing the Fan Button on either the r...

Страница 16: ...be in Fan Only Mode when the room temperature is below 81 F 27 C It will operate in Cooling Mode when the room temperature is above 81 F 27 C TIMER ON PROGRAM SETTING How to set When the unit is off y...

Страница 17: ...nected to it When the WATER FULL indicator light disappears the compressor will start to work again 5 3 OPERATING REMOTE CONTROL MODEL KY 25Y ONLY CONT D 5 4 WATER FULL INDICATION AND DRAINING DRAININ...

Страница 18: ...4 WATER FULL INDICATION AND DRAINING CONT D NOTE The cooling efficiency of your unit will be affected if the Drain Hose or the Garden Hose is always attached to it The Drain Hose or Garden Hose must...

Страница 19: ...A On a warm day turn the unit on in the FAN ONLY Mode for a couple of hours so that the inside can dry out completely B Turn off the unit and unplug the unit C Empty the residual condensated water by...

Страница 20: ...cribed in the Installation Instructions The water tank is full LCDI plug has tripped Press the RESET button on the LCDI plug The time is set properly Check if Then Open the air inlet and outlet The ai...

Страница 21: ...ormal The hot air discharging port is properly installed Install the hot air discharging port properly as instructed in this manual 7 4 THE UNIT TURNS ON AND OFF FREQUENTLY The outside temperature is...

Страница 22: ...am Products Inc utilis e sous licence Fabriqu en Chine pour Star Elite une division de Elite Group Inc Quebec Canada H3B 3X9 2006 Sunbeam Products Inc funcionando bajo el nombre de Jarden Consumer Sol...

Отзывы: