6.2 CLEANING OR REPLACING THE AIR FILTER

If the air filter is blocked with a lot of dust, the volume of airflow will be reduced and the cooling
effect will be lower.  It is recommended to clean the filter once every two weeks or as needed.

A)  Pull out the filter from the filter compartment in front of the unit.
B) Wash the air filter by immersing it gently into warm (about 104°F/40°C) water with a gentle

detergent.  Rinse the filter and dry it thoroughly in a shaded place.

C)  Place the filter back into the filter compartment after it is thoroughly dried.
D)  If the filter is torn or unusable, order a new filter by calling the Sunbeam Customer Service

department at 1-877-383-6399 (8:30am-5:30pm E.S.T.).

SECTION 6   

CARING FOR YOUR PORTABLE AIR CONDITIONER

18

6.3 EXTERNAL PLASTIC PARTS

A)  Keep the unit from being exposed directly to the sun.
B)  Clean the surface with a damp cloth. 
C)  For the Stainless Steel finished models, a good quality stainless steel cleaner should be used.

6.4 STORAGE AT THE END OF THE COOLING SEASON

A)  On a warm day, turn the unit on in the FAN-ONLY

Mode for a couple of hours so that the inside can dry
out completely.

B)  Turn off the unit and unplug the unit.
C)  Empty the residual condensated water by unplugging

the LOWER WATER DRAINAGE CAP at the back
towards the bottom of the unit. 

After connecting the

12’/3.65m white Drain Hose, ensure that the other end is
in a bucket or receptacle for gathering the water.

D)  Discharge the Hot air duct and shorten it and pack it

in the box.

E)   Clean the filter and dry it completely before fitting

back in place.

F)  Cover the appliance to protect it from dust. It is

recommended that the unit be put back into its
original box and package.

G)  The unit should be stored in a cool dry place.  Do not

stack heavy objects on the top of the unit.

Figure 17

Lower drain port

6.1 MAINTENANCE

WARNING

•  Make sure the power supply is switched off and the plug is pulled out of the power outlet

before performing any maintenance activities.

•  Do not immerse the unit in water or other liquids.
•  Do not pour liquids into the unit.
•   Take special precaution to avoid the sharp cutting edges of some parts.
•  Do not use any kind of chemical solvents to clean the unit, as they may deform the

unit cabinet.

Содержание KY-25

Страница 1: ...USER MANU AL GUIDE GUIDE D UTILISATION MODO DE EMPLEO 9 000BTU 9 000BTU Model KY 25 Y 9000 BTU PORTABLE DIGITAL AIR CONDITIONER WHITE METAL METAL BLANC METAL BLANCO Model KY 25 Y 9000 BTU PORTABLE DI...

Страница 2: ...9 SECTION 4 INSTALLATION INSTRUCTIONS 4 1 PORTABLE AIR CONDITIONER INSTALLATION 10 4 2 ASSEMBLING THE AIR EXHAUST DUCT 10 4 3 INSTALLING THE DUCTS IN THE WALL 11 SECTION 5 OPERATING YOUR PORTABLE AIR...

Страница 3: ...air conditioner follow these basic precautions Plug into an exclusive grounded 3 prong outlet Do not remove ground prong Do not use an adapter Use two or more people to move or install portable air co...

Страница 4: ...nit is supported by four castors In the event of fire use Carbon Dioxide CO2 extinguishers Do not use water or powder extinguishers Please help us to help you This portable air conditioner has been de...

Страница 5: ...lure to follow these instructions can result in death fire or electrical shock In the U S only If codes permit and a separate ground wire is used it is mandatory that the ground path is adequate Check...

Страница 6: ...wer conductors in an appliance cord and interrupts the circuit as a predetermined level of leakage current Since an LCDI specifically can detect a current leakage flowing to ground it provides ground...

Страница 7: ...ust duct for condenser side according to the installation instructions 1 8 UNPACKING YOUR PRODUCT PARTS Keep upright Figure 2 1 9 TECHNICAL SPECIFICATIONS Model Color Rate Cooling Capacity Voltage Fre...

Страница 8: ...number You can find this information on the model and serial number label Please record the model and serial number information below Also record the purchase date of your appliance Model Number Seria...

Страница 9: ...LS NEEDED 3 2 ACCESSORIES 1 Flat blade and Phillips screwdrivers 2 Gloves 3 Tape measure 4 Utility knife 8 Figure 5 1 Indoor terminal end 2 Exhaust duct 3 Window assembly kit 4 Main piece 5 Window kit...

Страница 10: ...not handle with damp or wet hands Do not squeeze the cable or let it come into contact with a sharp surface Do not use the power cables to drag the unit Do not leave the cable in a tangled coil when i...

Страница 11: ...nels if necessary Cut the window piece as needed to fit the length of your window or sliding door Make sure that the hole on the main piece is not covered by other pieces F Place the window kit in the...

Страница 12: ...commended that you use the shortest possible length of hose Take care to prevent any kind of bend in the middle of the exhaust hose as this will trap hot exhaust air which will radiate back into the r...

Страница 13: ...the fan speed High speed or Low speed 4 Up or Down Temperature or Time Changing Button Use these two buttons to set to your desired temperature The temperature unit can be on Fahrenheit or Centigrade...

Страница 14: ...ments When the unit is OFF if it hasn t been set on Time Delay press the Timer button The unit enters Timer Program Also the will flash in Timer Set Display Window and the Timer Indicator will be on i...

Страница 15: ...to your desired room temperature with the temperature ranges from 64 F 90 F 18 C 32 C Recommended temperatures are 80 F 84 F 27 C 29 C 5 Select the fan speed by pressing the Fan Button on either the r...

Страница 16: ...be in Fan Only Mode when the room temperature is below 81 F 27 C It will operate in Cooling Mode when the room temperature is above 81 F 27 C TIMER ON PROGRAM SETTING How to set When the unit is off y...

Страница 17: ...nected to it When the WATER FULL indicator light disappears the compressor will start to work again 5 3 OPERATING REMOTE CONTROL MODEL KY 25Y ONLY CONT D 5 4 WATER FULL INDICATION AND DRAINING DRAININ...

Страница 18: ...4 WATER FULL INDICATION AND DRAINING CONT D NOTE The cooling efficiency of your unit will be affected if the Drain Hose or the Garden Hose is always attached to it The Drain Hose or Garden Hose must...

Страница 19: ...A On a warm day turn the unit on in the FAN ONLY Mode for a couple of hours so that the inside can dry out completely B Turn off the unit and unplug the unit C Empty the residual condensated water by...

Страница 20: ...cribed in the Installation Instructions The water tank is full LCDI plug has tripped Press the RESET button on the LCDI plug The time is set properly Check if Then Open the air inlet and outlet The ai...

Страница 21: ...ormal The hot air discharging port is properly installed Install the hot air discharging port properly as instructed in this manual 7 4 THE UNIT TURNS ON AND OFF FREQUENTLY The outside temperature is...

Страница 22: ...am Products Inc utilis e sous licence Fabriqu en Chine pour Star Elite une division de Elite Group Inc Quebec Canada H3B 3X9 2006 Sunbeam Products Inc funcionando bajo el nombre de Jarden Consumer Sol...

Отзывы: