Model
Max. PV input current
Max. PV wire size
*
MAX-M2024
20A
6mm
2
/10AWG
MAX-M3024
30A
10mm
2
/8AWG
MAX-M4024
40A
16mm
2
/6AWG
*
These are the maximum wire sizes that will fit the controller terminals.
CAUTION:
When the PV modules connect in series, the open circuit
voltage of the PV array must not exceed 92V at 25
℃
environment
temperature.
Battery and Load Wire Size
The battery and load wire size must conform to the rated current, the reference size
as below:
Model
Rated
charge
current
Rated
discharge
current
Batterywire
size
Load wire
size
MAX-M2024
20A
20A
6mm
2
/10AWG
6mm
2
/10AWG
MAX-M3024
30A
30A
10mm
2
/8AWG
10mm
2
/8AWG
MAX-M4024
40A
40A
16mm
2
/6AWG
16mm
2
/6AWG
CAUTION:
The wire size is only for reference. If there is a long distance between the
PV array and the controller or between the controller and the battery, larger wires can
be used to reduce the voltage drop and improve performance.
CAUTION:
For the battery, the recommended wire will be selected
according to the conditions that its terminals are not connected to any
additional inverter.
2.4 Mounting
WARNING:
Risk of explosion! Never install the controller in a sealed
enclose with flooded batteries! Do not install in a confined area where
battery gas can accumulate.
WARNING:
Risk of electric shock! When wiring the solar modules, the PV
array can produce open circuit voltages in excess of 100V when in
sunlight.
10
Содержание MAX-M2024
Страница 1: ...MPPT Solar Charge Controller User Manual Models MAX M2024 MAX M3024 MAX M4024 ...
Страница 31: ...28 Annex II Dimensions MAX M2024 Unit mm 28 ...
Страница 32: ...29 MAX M3024 Unit mm 29 ...
Страница 33: ...30 MAX M4024 Unit mm 30 Any changes without prior notice Version number 1 0 ...