Tape Slot Locations
July 2012
Locations
31
Diagnostic and Cleaning Cartridge Locations
A total of up to 3 slots are allowed to be configured within the front left (Column 1)
of the base module. The reserved slots may contain diagnostic and cleaning
cartridges. The customer may not elect to configure any reserved slots, in which case
these are used as normal storage slots.
The user may configure up to 3 of these reserved slots in the base module magazine
beginning from row 1, column 1 and proceeding to row 3 of Column 1.
Reserved slots in a partitioned library must be configured prior to enabling
partitioning.
TABLE A-3
Slot Counts for Different Configurations
Module 1
Exp
a
ns
ion Module
To
ta
l S
lo
ts
Mailslot
s
as
S
torage Slot
s
Maxim
u
m Dr
ives
Module 1
30
30
4
2
Module 1 + 1 drive expansion
module
30
30
60
4
4
Module 1 + 2 drive expansion
modules
30
60
90
4
6
Module 1 + 3 drive expansion
modules
30
90
120
4
8
Module 1 + 4 drive expansion
modules
30
120
150
4
10
Module 1 + 5 drive expansion
modules
30
150
180
4
12
Module 1 + 6 drive expansion
modules
30
180
210
4
14
Module 1 + 7 drive expansion
modules
30
210
240
4
16
Module 1 + 8 drive expansion
modules
30
240
270
4
18
Module 1 + 9 drive expansion
modules
30
270
300
4
20
Note –
1. Expansion modules have 30 slots and 2 drives each (no mailslots)
2. When the mailslots are used for storage slots, add the mailslots count number in
that column to the number in the total slots column.
Содержание StorageTek SL150
Страница 6: ...6 SL150 Systems Assurance July2012 ...
Страница 8: ...8 SL150 Systems Assurance July2012 ...
Страница 10: ...Access to Oracle Support 10 SL150 Systems Assurance July2012 ...
Страница 18: ...Tape Drives and Media 18 SL150 Systems Assurance July2012 ...
Страница 22: ...Tape Drive Cleaning 22 SL150 Systems Assurance July2012 ...
Страница 32: ...Tape Slot Locations 32 SL150 Systems Assurance July2012 ...
Страница 50: ...Activity and Processes 50 SL150 Systems Assurance July2012 ...
Страница 60: ...60 SL150 Systems Assurance July2012 ...