38

SPARC T4-1B Server Module Installation Guide • May 2012

Related Information

“Install Oracle Solaris Software From the Network” on page 38

“Oracle Solaris Configuration Parameters” on page 38

“Assign a Static IP Address to the SP” on page 40

Install Oracle Solaris Software From
the Network

If you choose to use Oracle Solaris OS software other than the preinstalled Oracle
Solaris OS, you can install the operating system from the network.

Refer to the

Solaris Installation Guide: Network-Based Installations

for the version of

Oracle Solaris OS that you plan to use.

You can obtain this guide in the Oracle Solaris OS documentation collections that
are under the Systems Software category at:

http://http:www.oracle.com/technetwork/indexes/documentation/#

sys_sw

This guide includes information about using a JumpStart server.

Related Information

“Configure the OS” on page 37

“Oracle Solaris Configuration Parameters” on page 38

“Assign a Static IP Address to the SP” on page 40

Oracle Solaris Configuration Parameters

You are prompted to provide these parameters when configuring the Oracle Solaris
OS on the server module.

Parameter

Description

Language

Select a number from the displayed language list.

Locale

Select a number from the displayed locale list.

Содержание SPARC T4-1B

Страница 1: ...SPARC T4 1B Server Module Installation Guide Part No E22738 03 May 2012 ...

Страница 2: ...s sont concédés sous licence et soumis à des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer exécuter publier ou afficher le logiciel même partiellement sous quelque forme et par quelque procédé que ce soit Par ailleurs il est interdit de pr...

Страница 3: ...ifications 7 Environmental Specifications 8 Electrical Specifications 8 Preparing for Installation 11 Inventory 12 Handling Precautions 13 ESD Precautions 13 Tools Needed for Installation 14 Plan Communication With the Server Module During Installation 15 Dongle Cables 17 Installing the Server Module 21 Prepare the Modular System and Server Module 21 Install Optional Components 23 Insert the Serve...

Страница 4: ...b Power On the Host Through the CMM CLI 29 Method 2 Power On the Host Through the CMM SER MGT Port CLI 31 Method 3 Power On the Host Through the Front Panel SP CLI 34 Configuring the Oracle Solaris OS 37 Configure the OS 37 Install Oracle Solaris Software From the Network 38 Oracle Solaris Configuration Parameters 38 Assign a Static IP Address to the SP 40 Glossary 43 Index 49 ...

Страница 5: ...www oracle com documentation SPARC T4 1B server module http www oracle com pls topic lookup ctx SPARCT4 1B Sun Blade 6000 modular system http www oracle com pls topic lookup ctx E19938 01 Oracle Integrated Lights Out Manager Oracle ILOM http www oracle com pls topic lookup ctx ilom30 Oracle Solaris OS and other system software http www oracle com technetwork indexes documentation sys_sw Oracle VTS...

Страница 6: ...acle com goto docfeedback Support and Accessibility Description Links Access electronic support through My Oracle Support http support oracle com For hearing impaired http www oracle com accessibility support html Learn about Oracle s commitment to accessibility http www oracle com us corporate accessibility index html ...

Страница 7: ... Step Description Links 1 Review the product notes for any late breaking news SPARC T4 1B Server Module Product Notes 2 Review the server module features and components Server Module Overview on page 2 Front and Rear Panel Components on page 4 3 Review the server module requirements Confirming Server Module and Site Specifications on page 7 4 Confirm that you received all the items you ordered Inv...

Страница 8: ...lation Plan Communication With the Server Module During Installation on page 15 Dongle Cables on page 17 8 Install optional components in the server module and install the server module in the chassis Installing the Server Module on page 21 9 Power on the server module for the first time Powering On the Server Module for the First Time on page 27 10 Configure the OS on the host Configuring the Ora...

Страница 9: ...B 2 0 two connections Serial VGA video Local KVMS support Architecture SPARC V9 architecture ECC protected Platform group sun4v Platform name ORCL SPARC T4 1B Ethernet ports Two 10 100 1000 Mb Intel 82576EB ports PCI I O Two Gen2 capable PCI EM slots FEM Refer to the SPARC T4 1B Server Module Product Notes for details about supported FEMs System firmware Preinstalled on the SP Note Refer to the Se...

Страница 10: ...module 2 Universal connector port UCP 3 Drive slots 4 White LED Locator functions as the physical presence switch 5 Blue LED Ready to Remove 6 Amber LED Fault Service Action Required 7 Green LED OK 8 Power button 9 Reset button NMI for service use only 10 Green LED Drive OK 11 Amber LED Drive Fault Service Action Required 12 Blue LED Drive Ready to Remove ...

Страница 11: ...Understanding the Server Module 5 Related Information Server Module Overview on page 2 Installation Task Overview on page 1 13 Rear chassis power connector 14 Rear chassis data connection No Description ...

Страница 12: ...6 SPARC T4 1B Server Module Installation Guide May 2012 ...

Страница 13: ...llation of the server module Physical Specifications on page 7 Environmental Specifications on page 8 Electrical Specifications on page 8 Related Information Installing the Server Module on page 21 Installation Task Overview on page 1 Server Module Overview on page 2 Physical Specifications Measure U S Metric Width 1 8 in 44 5 mm Depth 20 1 in 511 7 mm Height 12 9 in 327 2 mm Weight Weight specifi...

Страница 14: ...Physical Specifications on page 7 Condition Requirement Operating temperature 5 C 41 F to 35 C 95 F noncondensing Nonoperating temperature 40 C 40 F to 65 C 149 F Operating humidity 10 to 90 noncondensing 27 C 80 F max wet bulb Nonoperating humidity 93 noncondensing 38 C 100 F max wet bulb Operating altitude 3048 meters 10 000 feet at 35 C 95 F Nonoperating altitude 12 000 meters 40 000 feet Measu...

Страница 15: ...Confirming Server Module and Site Specifications 9 Environmental Specifications on page 8 ...

Страница 16: ...10 SPARC T4 1B Server Module Installation Guide May 2012 ...

Страница 17: ... page 12 Handling Precautions on page 13 ESD Precautions on page 13 Tools Needed for Installation on page 14 Plan Communication With the Server Module During Installation on page 15 Dongle Cables on page 17 Related Information Installing the Server Module on page 21 Installation Task Overview on page 1 ...

Страница 18: ...ecautions on page 13 ESD Precautions on page 13 No Description 1 Printed documentation including Getting Started Guide 2 Server module 3 Customer information sheet on outside of shipping carton Save this sheet as a record of the MAC address and other information about installed hardware and software ...

Страница 19: ...Module During Installation on page 15 Dongle Cables on page 17 ESD Precautions Electronic equipment is susceptible to damage by static electricity Use a grounded antistatic wrist strap foot strap or equivalent safety equipment to prevent ESD when you install the server module Caution To protect electronic components from ESD which can permanently disable the system place components on an antistati...

Страница 20: ... Installation on page 15 Dongle Cables on page 17 Tools Needed for Installation The following tools are sufficient for installing the server module whether or not you need to install components inside the server module Antistatic mat Antistatic wrist strap UCP 3 or UCP 4 dongle cable Terminal or terminal emulator Stylus to press power button Related Information Dongle Cables on page 17 Handling Pr...

Страница 21: ...e Before you perform the installation arrange to have the equipment information and permissions required by that method Note For information about identifying and configuring IP and MAC addresses refer to the configuring network addresses information in the Server Module Administration Guide Choose one of the connection methods to communicate with the server module SP The connection methods are sh...

Страница 22: ...erface on page 28 and Method 1b Power On the Host Through the CMM CLI on page 29 a CMM Oracle ILOM web interface b CLI 2 Serial From CMM SER MGT port To Terminal device A terminal device connected to the CMM SER MGT RJ 45 port From this connection you can use Oracle ILOM to navigate to the server module SP Oracle ILOM CLI interface See Method 2 Power On the Host Through the CMM SER MGT Port CLI on...

Страница 23: ...ables should be removed when not in use These cables have not been evaluated for electromagnetic compatibility compliance and are not to be used during normal system operation There are two types of dongle cables you can use UCP 3 Three connector dongle cable preferred ships with the server module Use the RJ 45 connector to connect to the server module SP UCP 4 Four connector dongle cable previous...

Страница 24: ...ion Guide May 2012 FIGURE UCP 3 Three Connector Dongle Cable Figure Legend 1 Dongle connector attaching to the server module UCP 2 RJ 45 serial connector 3 USB 2 0 two connectors 4 VGA 15 pin female connector 5 Insertion and release buttons ...

Страница 25: ...13 Tools Needed for Installation on page 14 Plan Communication With the Server Module During Installation on page 15 Figure Legend 1 Dongle connector attaching to the server module UCP 2 RJ 45 serial connector Do not use this connector on the UCP 4 3 DB 9 serial male connector TTYA 4 USB 2 0 two connectors 5 VGA 15 pin female connector 6 Insertion and release buttons ...

Страница 26: ...20 SPARC T4 1B Server Module Installation Guide May 2012 ...

Страница 27: ...g the server module 1 Ensure that the modular system is installed and functional Satisfying the following conditions ensures a straightforward installation of the server module a Install the modular system into its intended rack before installing server modules Step Description Links 1 Prepare the modular system chassis and server module for installation Prepare the Modular System and Server Modul...

Страница 28: ...mware upgrade before you insert this server module or any other SAS 2 component into the modular system chassis Refer to the SAS 1 SAS 2 Compatibility Upgrade Guide for more information See Related Documentation on page v 3 Unpackage the server module Be ready to insert the server module within 60 seconds of removing the filler panel 4 Install any optional components See Install Optional Component...

Страница 29: ...he server module To install any optional components refer to the SPARC T4 1B Server Module Service Manual and to the documentation for the optional component 2 Close the server module 3 Insert the server module into the chassis See Insert the Server Module Into the Chassis on page 23 Related Information Prepare the Modular System and Server Module on page 21 Install Optional Components on page 23 ...

Страница 30: ...m 5 Remove the filler panel from the selected chassis slot Pull down the ejector arm of the filler panel then pull the panel straight out of the chassis Caution Be ready to insert the server module within 60 seconds of removing the filler panel 6 Use both hands to position the server module vertically with the ejector arms on the right panel 1 7 Push the server module into the empty slot until the...

Страница 31: ...d to power the server module goes into standby mode and its SP initializes The front panel LEDs blink three times then the green OK LED on the front panel blinks for a few minutes See Front and Rear Panel Components on page 4 Related Information Prepare the Modular System and Server Module on page 21 Install Optional Components on page 23 Front and Rear Panel Components on page 4 ...

Страница 32: ...26 SPARC T4 1B Server Module Installation Guide May 2012 ...

Страница 33: ...uide Description Links Through a browser that is on the same network as the CMM use the CMM ILOM web interface Method 1a Power On the Host Through the CMM Web Interface on page 28 Through a terminal window on a system that is on the same network as the CMM use the CMM ILOM CLI Method 1b Power On the Host Through the CMM CLI on page 29 Through a terminal device connected to the CMM SER MGT port use...

Страница 34: ...the IP address 129 99 99 99 enter http 129 99 99 99 into your browser A login window for ILOM appears 4 Log into ILOM on the CMM by typing your user name and password The factory default ILOM root password is changeme but might have been changed in your environment You are logged in to the CMM ILOM web interface 5 If the Chassis View image of the modular system is not displayed in the web interfac...

Страница 35: ...On of the server The server module host is powered on for the first time 10 You can now configure the Oracle Solaris OS to meet your needs See Configuring the Oracle Solaris OS on page 37 Related Information Plan Communication With the Server Module During Installation on page 15 Method 1b Power On the Host Through the CMM CLI You connect to the CMM through the RJ 45 NET MGT 0 Ethernet port While ...

Страница 36: ...igate to the server module SP Replace n with a number that identifies the chassis slot in the modular system where the target server module is installed 6 Access the server module SP If you are prompted for a password for the root user on the server module SP type changeme the factory default password You are now logged into ILOM on the server module SP ssh root cmm_ip_address Password CMM_ILOM_pa...

Страница 37: ...hardware installation is now complete You can now configure the Oracle Solaris OS to meet your needs See Configuring the Oracle Solaris OS on page 37 Related Information Plan Communication With the Server Module During Installation on page 15 Method 2 Power On the Host Through the CMM SER MGT Port CLI You can access the server module SP by first accessing the chassis CMM ILOM through a terminal or...

Страница 38: ...e location of the serial port The serial port requires a cable with these pin assignments 4 Press Enter on the terminal device The connection between the terminal device and the CMM is established If you connected to the serial port before the powering on the modular system you will see boot messages The CMM ILOM software displays its login prompt The first string in the prompt is the default host...

Страница 39: ...er that identifies the target server module the slot for which the server module is installed 7 Start the server module s Oracle ILOM CLI Note The CMM ILOM logs into the server module ILOM using the user name in the user target under CH BLn SP cli where n is the slot where the server module is installed 8 If prompted for a password enter the default password changeme 9 At the Oracle ILOM prompt ty...

Страница 40: ...ation With the Server Module During Installation on page 15 Method 3 Power On the Host Through the Front Panel SP CLI You can access the server module SP directly by connecting a dongle cable to the UCP on the front of the server module Caution Dongle cables are intended for setup testing or service purposes and should be removed when not in use These cables have not been evaluated for electromagn...

Страница 41: ...u are now logged into Oracle ILOM on the server module SP 5 At the server module ILOM prompt type The server module initializes 6 Switch communication to the server module host When the Oracle ILOM prompt appears type The server module might take several minutes to complete POST If a boot device installed with Oracle Solaris OS is accessible locally the server module boots Otherwise the server mod...

Страница 42: ...36 SPARC T4 1B Server Module Installation Guide May 2012 Dongle Cables on page 17 ...

Страница 43: ...te the Oracle Solaris OS installation then resume this procedure Respond to configuration questions in the Oracle Solaris installation process See the configuration choices you planned based on Oracle Solaris Configuration Parameters on page 38 Description Links Configure the preinstalled Oracle Solaris OS Configure the OS on page 37 Oracle Solaris Configuration Parameters on page 38 Assign a Stat...

Страница 44: ...f Oracle Solaris OS that you plan to use You can obtain this guide in the Oracle Solaris OS documentation collections that are under the Systems Software category at http http www oracle com technetwork indexes documentation sys_sw This guide includes information about using a JumpStart server Related Information Configure the OS on page 37 Oracle Solaris Configuration Parameters on page 38 Assign...

Страница 45: ... to use IPv6 If you are not sure select No to configure the Ethernet interface for IPv4 Security Policy Select either standard UNIX security No or Kerberos Security Yes If you are not sure select No Confirm Review the onscreen information and change it if needed Otherwise continue Name Service Select the name service according to your network environment Note If you select a name service other tha...

Страница 46: ...le uses 255 255 255 0 to set the netmask Your network environment subnet might require a different netmask Use a netmask number most appropriate to your environment 5 Verify that the pending parameters are set correctly set SP network pendingipdiscovery static Set pendingipdiscovery to static set SP network pendingipaddress service processor IPaddr Set pendingipaddress to service processor IPaddr ...

Страница 47: ...on page 37 Install Oracle Solaris Software From the Network on page 38 Oracle Solaris Configuration Parameters on page 38 ipnetmask 255 255 255 0 macaddress 00 21 28 C1 6E C5 managementport SYS MB SP NETMGMT outofbandmacaddress 00 21 28 C1 6E C5 pendingipaddress service processor IPaddr pendingipdiscovery static pendingipgateway gateway IPaddr pendingipnetmask 255 255 255 0 pendingmanagementport S...

Страница 48: ...42 SPARC T4 1B Server Module Installation Guide May 2012 ...

Страница 49: ...AWG American wire gauge B blade Generic term for server modules and storage modules See server module and storage module blade server Server module See server module BMC Baseboard management controller BOB Memory buffer on board C chassis For servers refers to the server enclosure For server modules refers to the modular system enclosure CMA Cable management arm ...

Страница 50: ...iguration Protocol disk module or disk blade Interchangeable terms for storage module See storage module DTE Data terminal equipment E EIA Electronics Industries Alliance ESD Electrostatic discharge F FEM Fabric expansion module FEMs enable server modules to use the 10GbE connections provided by certain NEMs See NEM FRU Field replaceable unit H HBA Host bus adapter host The part of the server or s...

Страница 51: ...one mouse with more than one computer L LwA Sound power level M MAC Machine access code MAC address Media access controller address Modular system The rackmountable chassis that holds server modules storage modules NEMs and PCI EMs The modular system provides Oracle ILOM through its CMM MSGID Message identifier N name space Top level Oracle ILOM CMM target NEBS Network Equipment Building System Ne...

Страница 52: ...tegrated Lights Out Manager Oracle ILOM firmware is preinstalled on a variety of Oracle systems Oracle ILOM enables you to remotely manage your Oracle servers regardless of the state of the host system Oracle Solaris OS Oracle Solaris operating system P PCI Peripheral component interconnect PCI EM PCIe ExpressModule Modular components that are based on the PCI Express industry standard form factor...

Страница 53: ...U and memory in a modular system Server modules might also have onboard storage and connectors that hold REMs and FEMs SP Service processor In the server or server module the SP is a card with its own OS The SP processes Oracle ILOM commands providing lights out management control of the host See host SSD Solid state drive SSH Secure shell storage module Modular component that provides computing s...

Страница 54: ...n Guide May 2012 UI User interface UL Underwriters Laboratory Inc US NEC United States National Electrical Code UTC Coordinated Universal Time UUID Universal unique identifier W WWN World wide name A unique number that identifies a SAS target ...

Страница 55: ...T port CLI 31 UCP connector 34 connection methods 15 connector covers 23 cooling 2 customer information sheet 12 D data connector 4 depth 7 DHCP used to obtain IP address 40 dimensions 7 DIMM types 2 documentation related v dongle cable 15 34 dongle cables 15 17 34 E ejector arms 23 electrical specifications 8 environmental specifications 8 ESD precautions 13 Ethernet ports 2 F features server mod...

Страница 56: ...ure 2 R rear panel components 4 related documentation v remote console 28 REMs 2 reset button 4 root password default 28 S serial cable pin assignments 31 serial port connection 15 17 serial redirection 28 server module configuring the OS 37 features 2 inserting into chassis 23 installing 21 installing the OS from the network 38 powering on 27 starting 31 understanding 1 set command 40 shipping ki...

Страница 57: ...Index 51 weight 7 width 7 ...

Страница 58: ...52 SPARC T4 1B Server Module Installation Guide May 2012 ...

Отзывы: