Chapter 2
Installation and Configuration
15
Connecting to the Server Module SP Through the Chassis
CMM Serial Connector
You can access the CMM ILOM by connecting a terminal or a terminal emulator to
the RJ-45 serial port on the chassis. Once the server module is installed in the
modular system chassis, you can connect to the server module SP by using the CLI
on the CMM ILOM software.
▼
To Connect Through the Chassis Serial Connector
1. Verify that your terminal, laptop, or terminal server is operational.
2. Configure the terminal device or terminal emulation software to use the
following settings:
■
8N1: eight data bits, no parity, one stop bit
■
9600 baud (default, can be set to any standard rate up to 57600)
■
Disable hardware flow control (CTS/RTS)
3. Connect a serial cable from the serial port on the chassis to a terminal device.
Refer to the modular system chassis documentation for the location of the serial
port.
Note –
The serial port requires the pin assignments described in
. Note that
these are the same as the serial cable connector for the Sun Advanced Lights Out
Manager (ALOM) or Remote System Control (RSC).
TABLE 2-1
Serial Management Port Pinouts
Pin
Signal Description
1
Request To Send (RTS)
2
Data Terminal Ready (DTR)
3
Transmit Data (TXD)
4
Ground
5
Ground
6
Receive Data (RXD)
7
Data Carrier Detect (DCD)
8
Clear To Send (CTS)
Содержание BLADE T6320
Страница 1: ...Sun Blade T6320 Server Module Installation Guide Part No 820 2384 11 April 2010 Revision A...
Страница 4: ......
Страница 10: ...x Sun Blade T6320 Server Module Installation Guide April 2010...
Страница 18: ...8 Sun Blade T6320 Server Module Installation Guide April 2010...
Страница 40: ...30 Sun Blade T6320 Server Module Installation Guide April 2010...