Chapter 1
Sun StorEdge T3 Disk Tray Overview
1-9
1.4
Architecture
The Sun StorEdge T3 disk tray is uniquely designed to be a modular, scalable,
reliable, serviceable, high-performance building block with a flexible configuration.
The design allows for multiple disk trays to be combined in various ways to provide
complete storage solutions that are optimized for all applications—from transaction
processing to decision support and high-performance computing, from workgroup
environments to data centers.
The disk tray units have redundant components for high reliability. Components are
hot swappable and field replaceable for serviceability. Controller units have a cached
hardware RAID controller for high performance. Expansion units can be added to
scale capacity. Controllers can be added to expansion units to scale performance.
Controller units can be paired in a partner group, providing controller and data path
redundancy and mirrored caches for high availability. Partner groups support host-
based alternate pathing for enhanced availability.
Data and administrative paths are completely independent for reliability, security,
serviceability, and ease of use. The network-based administrative path allows for
centralized configuration and monitoring of large numbers of Sun StorEdge T3 disk
tray configurations providing storage to multiple application servers.
Each disk drive has a drive label, a small portion of which is reserved for the system
area. Approximately 150 Mbytes is reserved for the system area, which contains the
configuration data, boot firmware, and file system information. This information is
mirrored across all nine drives for redundancy so that data can be recovered from
the other functional drives.
Finally, the unique switched-loop architecture provides the flexibility to configure
multiple units together for scalability and availability, while enabling loops to be
reconfigured dynamically for diagnosis and recovery in case of loop-related failures.
Содержание Sun StorEdge T3
Страница 6: ...vi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Страница 14: ...xiv Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Страница 26: ...xxvi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Страница 38: ...1 12 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Страница 84: ...2 46 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Страница 104: ...4 10 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Страница 134: ...A 6 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Страница 138: ...B 4 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 FIGURE B 7 Front Panel Front panel ...