Sun Fire X4150 Server Product Notes
37
■
“Correctable Errors Incorrectly Listed in the ILOM SEL as a Critical Error” on
page 37
■
“Must Be Physically Present When Logging Into Serial Console With the Default
Account” on page 37
■
“Time on SP Resets to January 1, 1970, When the System is Power-Cycled
(6739395, 6739868)” on page 37
■
“Selecting the Web Interface Time-out Duration” on page 38
■
“Selecting Mouse Mode Settings According to Host OS” on page 38
■
“Switch Control Between Local Mouse and Host Mouse” on page 38
Correctable Errors Incorrectly Listed in the ILOM SEL as
a Critical Error
Correctable errors detected by the background scrubber in ILOM: 3.0.3.30 build
r48374 are incorrectly listed in the ILOM system event log (SEL) as a critical error
with the following description:
Memory Scrub Failed
These messages are caused by Correctable ECC Error, which should have a severity
of minor, not critical. This SEL message will be fixed in a future release.
Must Be Physically Present When Logging Into Serial
Console With the Default Account
Physical presence is required when you try to log in with default account from the
serial console. You will need to press the Locate button twice for the system to
recognize your physical presence.
Time on SP Resets to January 1, 1970, When the System is
Power-Cycled (6739395, 6739868)
ILOM stores the time in a file every 15 minutes. After the system reboots, the time is
restored to whatever time was last written to that file plus a small delta. So in most
cases, major events have timestamps that are monotonically increasing.
During the boot process, the date might temporarily be displayed as January 1, 1970.
This will automatically change to the current time once the boot process reaches the
timestamp file check.