Sun Fire X4150 Server Product Notes • February 2010
2. Install the Solaris patches (ELOM and ILOM).
See
“Installing Solaris Patches” on page 13
3. Reboot Solaris.
4. Replace the shipped processors with the new Intel Xeon 5300 or 5400 series
processors.
Refer to the
Sun Fire X4150 Server Service Manual
for information on removing and
installing the processors.
▼
Updating the CPLD
1. Start the Embedded LOM (ELOM) SP web GUI by typing the IP address of the
SP into a browser.
See the
Embedded Lights Out Manager Administration Guide
for instructions on
using the ELOM web GUI.
2. Copy the file
/remoteflash/elom/CPLD/s92v063.jbc
to the local drive
from the Tools and Drivers version 1.1 CD.
3. Log in to the SP.
4. Click on the Maintenance Tab and choose Firmware Update.
Shut the server down if you are prompted.
The Firmware Update screen is displayed.
5. From the CPLD Update option, click Browse and navigate to the location of the
flash file.
6. Click Update.
The firmware uploads.
7. After the firmware is uploaded, you are asked to remove AC power for 10
seconds to allow the CPLD to be loaded.
Power the server off and then restart the server.
8. After the CPLD update is finished, the BIOS/SP can be updated from the
bootable Tools and Drivers version 1.1 CD or through the documented TFTP
interface and Web Interface.
See the
Embedded Lights Out Manager Administration Guide.