Chapter 4
Network Interfaces and System Firmware
59
Enabling or Disabling the OpenBoot
Environmental Monitor
The OpenBoot environmental monitor is enabled by default whenever the system is
operating at the
ok
prompt. However, you can enable or disable it yourself using the
OpenBoot commands
env-on
and
env-off
. For more information, see:
■
“How to Enable OpenBoot Environmental Monitoring” on page 160
■
“How to Disable OpenBoot Environmental Monitoring” on page 160
Note –
Using the Stop-A keyboard command to enter the OpenBoot environment
during power-on or reset will immediately disable the OpenBoot environmental
monitor. If you want the OpenBoot PROM environmental monitor enabled, you
must reenable it prior to rebooting the system. If you enter the OpenBoot
environment through any other means—by halting the operating system, by
power-cycling the system, or as a result of a system panic—the OpenBoot
environmental monitor will remain enabled.
Automatic System Shutdown
If the OpenBoot environmental monitor detects a critical overtemperature condition,
it will initiate an automatic system shutdown sequence. In this case, a warning
similar to the following is generated to the system console:
If necessary, you can type Ctrl-C to abort the automatic shutdown and return to the
system
ok
prompt; otherwise, after the 30 seconds expire, the system will power off
automatically.
Note –
Typing Ctrl-C to abort an impending shutdown also has the effect of
disabling the OpenBoot environmental monitor. This gives you enough time to
replace the component responsible for the critical condition without triggering
another automatic shutdown sequence. After replacing the faulty component, you
must type the
env-on
command to reinstate OpenBoot environmental monitoring.
WARNING: SYSTEM POWERING DOWN IN 30 SECONDS!
Press Ctrl-C to cancel shutdown sequence and return to ok prompt.
Содержание Sun Fire V480
Страница 4: ...iv Sun Fire V480 Server Parts Installation and Removal Guide February 2002 ...
Страница 8: ...viii Sun Fire V480 Server Administration Guide February 2002 ...
Страница 18: ...xviii Sun Fire V480 Server Administration Guide February 2002 ...
Страница 20: ...xx Sun Fire V480 Server Administration Guide February 2002 ...
Страница 28: ...xxviii Sun Fire V480 Server Administration Guide February 2002 ...
Страница 30: ......
Страница 38: ......
Страница 56: ...28 Sun Fire V480 Server Administration Guide February 2002 ...
Страница 106: ...78 Sun Fire V480 Server Administration Guide February 2002 ...
Страница 152: ......
Страница 176: ...148 Sun Fire V480 Server Administration Guide February 2002 ...
Страница 186: ...158 Sun Fire V480 Server Administration Guide February 2002 ...
Страница 200: ...172 Sun Fire V480 Server Administration Guide February 2002 ...
Страница 216: ...188 Sun Fire V480 Server Administration Guide February 2002 ...
Страница 240: ...212 Sun Fire V480 Server Administration Guide February 2002 ...
Страница 270: ...Index 242 Sun Fire V480 Server Administration Guide February 2002 ...