Chapter 3
Sun StorageTek 6540 Array Installation Requirements
25
Environmental Requirements
This section describes the environmental conditions that are prerequisite to installing
the unit, and heat conditions that are generated by normal operation of the unit.
lists the environmental conditions in which the 6540 array is designed to
operate.
lists the nonoperating environmental conditions of the 6540 controller tray.
TABLE 3-2
Operating Environmental Conditions
Condition
Range
Temperature
32
°
F to 104
°
F (0
°
C to 40
°
C)
10
°
C to 35
°
C (50
°
F to 95
°
F) with battery
Relative humidity
20% to 80% noncondensing
Altitude
100 feet (30.5 meters) below sea level to 9,840
feet (3,000 meters)
Shock
Operating: 10 G, 3.75ms half triangular
Nonoperating: 20 G, 8.0 ms square wave in each
direction along x, y, and z axis
Vibration
0.20 G, 5 to 500 Hz sinusoidal
Heat output
233 watts (797 BTU/hour)
TABLE 3-3
Nonoperating Environmental Conditions
Condition
Range
Temperature (storage)
14
°
F to 149
°
F (-10
°
C to 65
°
C)
Temperature (transit)
-40
°
F to 149
°
F (-40
°
C to 65
°
C)
Humidity (storage)
10% to 93%
Humidity (transit)
5% to 95%
Altitude
100 feet (30.5 meters) below sea level to 40,000 feet (12,000
meters) above sea level
Shock
30 G, 11 msec half sinewave in the side/side and up/down
directions
5 G, 11 msec half sinewave in the front/back direction
Содержание StorageTek 6540
Страница 6: ...vi Sun StorageTek 6540 Rack Ready Site Preparation and Installation Support Guide July 2006 ...
Страница 18: ...6 Sun StorageTek 6540 Rack Ready Site Preparation and Installation Support Guide July 2006 ...
Страница 34: ...22 Sun StorageTek 6540 Rack Ready Site Preparation and Installation Support Guide July 2006 ...
Страница 42: ...30 Sun StorageTek 6540 Rack Ready Site Preparation and Installation Support Guide July 2006 ...
Страница 46: ...34 Sun StorageTek 6540 Rack Ready Site Preparation and Installation Support Guide July 2006 ...