Netra CP3060 Board User’s Guide • April 2009
FIGURE 2-2
Installing a DDR-2 DIMM Memory Module
Caution –
Do not rock the DDR-2 DIMM into place. Ensure that all contacts engage
at the same time. You will feel or hear a click when the DDR-2 DIMM properly seats
in the connector.
4. Press the top edge of the DDR-2 DIMM toward the blade server until the
retainer clips click into place (see
The small retainer clips on each side of the DDR-2 DIMM slot click into place in
the notches on the sides of the DDR-2 DIMM.
2.4.1.2
Removing a DDR-2 DIMM Memory Module
You might need to remove a DDR-2 DIMM module from the Sun Netra CP3060
blade server if you are returning the DDR-2 DIMM module or the blade server for
service, or if you are replacing a module with another DDR-2 DIMM module.
Note –
Safely store the original factory-shipped DDR-2 DIMM and related DDR-2
DIMM packaging. You might wish to store any removed DDR-2 DIMM in the new
DDR-2 DIMM packaging, or use the packaging for service.
To remove a DDR-2 DIMM from the Sun Netra CP3060 blade server, perform the
following steps:
1. Take antistatic precautions: attach and electrically ground the wrist strap.