background image

5-6

Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix • June 2003

See

FIGURE A-12

for power wiring diagram for

TABLE 5-6

.

TABLE 5-6

Sun Fire 3800 System With Sun StorEdge D240 Media Trays and Sun
StorEdge T3 Dual Array Unit

Rack Hole Numbers
Used To Mount Rails

Rack Holes To Mount
Device

Used Rack
Units

Available
Rack Units

RTU Rear

*1, 7

3

RTU Front

*10, 16

3

Sun Fire 3800 system

See TABLE 5-1

9

Sun StorEdge D240 media tray #1

110, *113

111, 112

2

Sun StorEdge D240 media tray #2

104, *107

105, 106

2

Sun StorEdge T3 dual array unit

49, 54, *64

49, 54

7

Total

26

12

Содержание Fire 6800

Страница 1: ...0 Network Circle Santa Clara CA 95054 U S A Send comments about this document to http www sun com hwdocs feedback Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix Part No 816 2062...

Страница 2: ...osystems Inc 4150 Network Circle Santa Clara CA 95054 Etats Unis Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation...

Страница 3: ...n Fire 6800 System Rackmount Matrix 2 1 3 Sun Fire 4810 System Rackmount Placement Matrix 3 1 4 Sun Fire 4800 System Rackmount Placement Matrix 4 1 5 Sun Fire 3800 System Rackmount Placement Matrix 5...

Страница 4: ...4 Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix June 2003...

Страница 5: ...FIGURE A 3 RTU and RTS Modules A 3 FIGURE A 4 Sun Fire 6800 System and One Two or Three Sun StorEdge D240 Media Trays A 4 FIGURE A 5 Sun Fire 6800 System and One Sun StorEdge D240 Media Tray and One...

Страница 6: ...0 Systems Two Sun StorEdge D240 Media Trays and One or Two Sun StorEdge A1000 Arrays or Sun StorEdge D1000 Arrays or Sun StorEdge T3 Arrays A 12 FIGURE A 15 Three Sun Fire 3800 Systems and Three Sun S...

Страница 7: ...rEdge D1000 or A1000 or T3 Array 3 2 TABLE 3 3 Sun Fire 4810 System With Sun StorEdge D240 Media Trays and Sun StorEdge T3 Dual Array 3 3 TABLE 3 4 Sun Fire 4810 System With Sun StorEdge D240 Media Tr...

Страница 8: ...Arrays 5 4 TABLE 5 5 Sun Fire 3800 System With Sun StorEdge D240 Media Trays and Sun StorEdge A1000 or D1000 Array and Sun StorEdge T3 Array 5 5 TABLE 5 6 Sun Fire 3800 System With Sun StorEdge D240...

Страница 9: ...r wiring diagrams for connecting power cables between the respective systems and storage products to the redundant transfer unit s RTU within the cabinet Who Should Use This Book Caution This book is...

Страница 10: ...vices are mounted Appendix A describes all of the power wiring configurations Related Documentation Accessing Sun Documentation You can view print or purchase a broad selection of Sun documentation in...

Страница 11: ...areas can result in serious injury or death Caution Improper handling by unqualified personnel can cause serious damage to this equipment Unqualified personnel who tamper with this equipment may be he...

Страница 12: ...Placement Matrix June 2003 For system compliance class and conformity information refer to the system installation guide that came with your system Procedures contained in this document must be perfor...

Страница 13: ...they may touch dangerous voltage points or short out components that could result in fire or electric shock Refer servicing of equipment to qualified personnel To protect both yourself and the equipme...

Страница 14: ...roperly grounded power outlets as described in the installation guides Caution DO NOT make mechanical or electrical modifications to the system or the cabinet Sun Microsystems is not responsible for r...

Страница 15: ...depending on what system is installed in the Sun Fire Cabinet Sun Fire cabinet N A 325 lbs 147 kg 2 to 4 N A N A Sun Fire 6800 system 31 1030 lbs 467 2 kg 4 1 N A Sun Fire 4810 system 21 326 lbs 147...

Страница 16: ...ement Matrix June 2003 Caution To prevent personal injury use a computer equipment mechanical lift and two people to move any system or array weighing more than 50 lbs 22 7 kg safely into the cabinet...

Страница 17: ...acks When considering third party rack mounting the third party thermal guidelines and the third party rack mounting guidelines should be reviewed The Sun Fire 280R Sun Enterprise 420R Sun Netra T1 AC...

Страница 18: ...re Cabinet Rackmount Placement Matrix June 2003 Note Before you begin carefully read each of the procedures in this manual If you have not performed similar operations on comparable equipment do not a...

Страница 19: ...2 1 CHAPTER 2 Sun Fire 6800 System Rackmount Matrix This chapter describes where to mount various storage devices within the Sun Fire 6800 system cabinet FIGURE 2 1 Sun Fire 6800 System Front View...

Страница 20: ...ck Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units Sun Fire 6800 system 31 Sun StorEdge D240 media tray 1 110 113 111 112 2 Sun StorEdge D240 media tra...

Страница 21: ...3 Sun Fire 6800 System With Sun StorEdge D240 Media Tray and Sun StorEdge T3 Array System Storage Device Rack Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rac...

Страница 22: ...2 4 Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix June 2003...

Страница 23: ...ER 3 Sun Fire 4810 System Rackmount Placement Matrix This chapter describes where to mount various storage devices within the Sun Fire 4810 system cabinet FIGURE 3 1 Sun Fire 4810 Rackmounted System F...

Страница 24: ...Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 RTU Front for reference only 10 16 3 Sun Fire 4810 system 20 22 21 Sun StorEdge D240 media tray 1 110 113 111...

Страница 25: ...Sun StorEdge D240 media tray 2 104 107 105 106 2 Sun StorEdge T3 dual array 85 90 100 85 90 7 Total 38 0 See FIGURE A 12 for power wiring diagram for TABLE 3 4 TABLE 3 4 Sun Fire 4810 System With Sun...

Страница 26: ...112 2 2 Sun StorEdge D240 media tray 2 104 107 105 106 2 Sun StorEdge D1000 array or Sun StorEdge A1000 array 84 87 86 89 4 4 Sun StorEdge D1000 array or Sun StorEdge A1000 array 96 99 98 101 4 Total...

Страница 27: ...ER 4 Sun Fire 4800 System Rackmount Placement Matrix This chapter describes where to mount various storage devices within the Sun Fire 4800 system cabinet FIGURE 4 1 Sun Fire 4800 Rackmounted System F...

Страница 28: ...ays Rack Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 RTU Front for reference only 10 16 3 Sun Fire 4800 system 21 24 66 68 18 Sun Fi...

Страница 29: ...Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 RTU Front 10 16 3 Sun Fire 4800 system 21 24 66 68 18 Sun Fire 1 2 RU filler panel 71 tabs down Sun S...

Страница 30: ...4 Sun StorEdge T3 array 2 89 93 90 93 4 4 Total 35 33 37 3 or 5 or 1 See FIGURE A 12 for power wiring diagram for TABLE 4 5 and TABLE 4 6 TABLE 4 5 Sun Fire 4800 System With Sun StorEdge D240 Media Tr...

Страница 31: ...dge T3 Array Rack Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 RTU Front 10 16 3 Sun Fire 4800 system 21 24 66 68 18 Sun Fire 1 RU fi...

Страница 32: ...4 6 Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix June 2003...

Страница 33: ...5 Sun Fire 3800 System Rackmount Placement Matrix This chapter describes where to mount various storage devices within the Sun Fire 3800 system cabinet FIGURE 5 1 Two Sun Fire 3800 Rackmounted Systems...

Страница 34: ...re 3800 systems are installed you must always have a 1 2 RU metal filler panel in the space above it Empty space in the cabinet must be filled with filler panels to prevent the recycling of heated exh...

Страница 35: ...ystem See TABLE 5 1 9 Sun StorEdge D240 media tray 1 110 113 111 112 2 Sun StorEdge D240 media tray 2 104 107 105 106 2 Total 19 19 TABLE 5 3 Sun Fire 3800 System With Sun StorEdge D240 Media Trays an...

Страница 36: ...Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 3 3 RTU Front 10 16 3 3 3 Sun Fire 3800 system See TABLE 5 1 9 9 9 Sun StorEdge D240 media t...

Страница 37: ...rray and Sun StorEdge T3 Array Rack Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 RTU Front 10 16 3 Sun Fire 3800 system See TABLE 5 1...

Страница 38: ...e D240 Media Trays and Sun StorEdge T3 Dual Array Unit Rack Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 RTU Front 10 16 3 Sun Fire 3...

Страница 39: ...rays Rack Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 3 3 RTU Front 10 16 3 3 3 Sun Fire 3800 system See TABLE 5 1 9 9 9 Sun StorEdg...

Страница 40: ...To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 3 3 RTU Front 10 16 3 3 3 Sun Fire 3800 system 1 See TABLE 5 1 9 9 9 Sun Fire 3800 system 2 See TABLE 5 1...

Страница 41: ...Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 3 3 RTU Front 10 16 3 3 3 Sun Fire 3800 system 1 See TABLE 5 1 9 9 9 Sun Fire 3800 system 2 See TABLE 5 1 9 9 9 Sun StorE...

Страница 42: ...k Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 3 RTU Front 10 16 3 3 Sun Fire 3800 system 1 See TABLE 5 1 9 9 Sun Fire 3800 system 2...

Страница 43: ...StorEdge T3 Dual Array Unit Rack Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 RTU Front 10 16 3 Sun Fire 3800 system 1 See TABLE 5 1...

Страница 44: ...rays Rack Hole Numbers Used To Mount Rails Rack Holes To Mount Device Used Rack Units Available Rack Units RTU Rear 1 7 3 RTU Front 10 16 3 Sun Fire 3800 system 1 SEE Table 5 1 8 5 Sun Fire 3800 syste...

Страница 45: ...Fire 4800 3800 Systems Rackmount Placement Matrix This chapter describes where to mount various storage devices within the Sun Fire 4800 3800 systems cabinet FIGURE 6 1 Sun Fire 4800 3800 Rackmounted...

Страница 46: ...el in the space above it Empty space in the cabinet must be filled with filler panels to prevent the recycling of heated exhausted air from the rear of the system Filler panels range from 1 RU to 5 RU...

Страница 47: ...media tray 1 110 113 111 112 2 Sun StorEdge D240 media tray 2 104 107 105 106 2 Total 37 1 TABLE 6 1 Sun Fire 4800 3800 Systems With One or Two Sun StorEdge D240 Media Trays Continued Rack Hole Number...

Страница 48: ...6 4 Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix June 2003...

Страница 49: ...fer Units RTUs with four Redundant Transfer Switches RTSs Two totally independent AC power sources are needed for input power redundancy The AC power sources must be derived from independent power com...

Страница 50: ...e front on the left and one in the rear of the system on the left FIGURE A 2 Connecting the alternate RTS units to outlets that use the same power source as the default RTS units is not supported and...

Страница 51: ...A Functional Power and Data Wiring Diagrams A 3 FIGURE A 3 RTU and RTS Modules RTS0 module J1 is only for use with the Sun Fire 6800 system only J2 is never to be used J11 J12 J1 J3 J5 J7 J9 J8 J10 J...

Страница 52: ...media tray 2 Fan power Media tray power System power Note J11 J12 are unswitched Note Switched outlet callouts are for reference only Power connectionscan be with any switched outlet of the same RTU...

Страница 53: ...J3 J5 J7 J9 J1 RTU rear 1 J11 J3 J5 J7 J9 J1 J12 J4 J6 J8 J10 RTS0 RTS1 RTS3 RTS2 RTF1 RTF0 Sun StorEdge A1000 array or Sun StorEdge D1000 array or Sun StorEdge T3 array Fan power Media tray power Sys...

Страница 54: ...configurations with two RTU assemblies and one AC power sources there will be two cables to connect one in the front on the left and one in the rear of the system on the left FIGURE A 7 Connecting the...

Страница 55: ...AC Power Sources In configurations with one RTU assembly and one AC power sources there will be only one cable to connect in the rear of the system on the left FIGURE A 9 FIGURE A 9 One RTU Assembly a...

Страница 56: ...r 1 J11 J3 J5 J7 J9 J1 J12 J4 J6 J8 J10 J2 RTS0 RTS1 Sun StorEdge D240 media tray 2 RTF0 RTF1 Fan power Media tray power System power Note J11 J12 are unswitched Note Switched outlet callouts are for...

Страница 57: ...rear 1 J11 J3 J5 J7 J9 J1 J12 J4 J6 J8 J10 J2 RTS0 RTS1 RTF1 RTF0 Sun StorEdge A1000 array or Sun StorEdge D1000 array or Sun StorEdge T3 array Fan power Media tray power System power Note J11 J12 are...

Страница 58: ...2 J11 J3 J5 J7 J9 J1 RTU rear 1 J11 J3 J5 J7 J9 J1 J12 J4 J6 J8 J10 J2 RTS0 RTS1 RTS3 RTS2 Sun StorEdge A1000 array or Sun StorEdge D1000 array or Sun StorEdge T3 array Sun StorEdge A1000 array or Sun...

Страница 59: ...n Fire 3800 system 2 RTU front 2 J12 J4 J6 J8 J10 J2 J11 J3 J5 J7 J9 J1 RTU rear 1 J11 J3 J5 J7 J9 J1 J12 J4 J6 J8 J10 J2 RTS0 RTS1 RTS3 RTS2 RTF0 RTF1 Fan power Media tray power System power Note J11...

Страница 60: ...11 J3 J5 J7 J9 J1 RTS3 RTS2 RTU rear 1 J11 J3 J5 J7 J9 J1 J12 J4 J6 J8 J10 J2 RTS0 RTS1 RTF0 RTF1 Sun StorEdge A1000 array or Sun StorEdge D1000 array or Sun StorEdge T3 array Sun StorEdge A1000 array...

Страница 61: ...front 2 J12 J4 J6 J8 J10 J2 J11 J3 J5 J7 J9 J1 RTS3 RTS2 RTU rear 1 J11 J3 J5 J7 J9 J1 J12 J4 J6 J8 J10 J2 RTS0 RTS1 RTF0 RTF1 Sun Fire 3800 system 3 Y power Sun StorEdge D240 media tray 3 Note J11 J...

Страница 62: ...ont 2 J12 J4 J6 J8 J10 J2 J11 J3 J5 J7 J9 J1 RTU rear 1 J11 J3 J5 J7 J9 J1 J12 J4 J6 J8 J10 J2 RTS0 RTS1 RTS3 RTS2 Sun Fire 3800 system RTF1 RTF0 Fan power Media tray power System power Note J11 J12 a...

Страница 63: ...connects to B of A B splitter for SC1 Connector P2 connects to B of A B splitter for SC0 Connectors A of both A B splitter cables are for NTS tip console con nections RTU front 2 RTS2 RTS3 RTU rear 1...

Страница 64: ...or P3 connects to B of A B splitter for SC1 Connector P2 connects to B of A B splitter for SC0 Connectors A of both A B splitter cables are for NTS tip console con nections RTU front 2 RTS3 RTS2 RTU r...

Страница 65: ...s to B of A B splitter for SC1 Connector P2 connects to B of A B splitter for SC0 Connectors A of both A B splitter cables are for NTS tip console con nections RTU front 2 RTS2 RTS3 RTU rear 1 RTS1 RT...

Страница 66: ...A 18 Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix June 2003...

Отзывы: