background image

Care and Maintenance

Cleaning After Use

Clean and disinfect your tanning bed’s bench and canopy after each
use. Use a non-abrasive disinfectant cleaner that 

does not contain

ammonia or ammonia derivatives

. Ammonia may damage the acrylic

shield. Spray the acrylic lightly with disinfectant and wipe dry with a
clean soft cloth.

Thorough Periodic Cleaning

The cooling fans draw air through the bed and will cause a dust
buildup on the lamps and reflectors. When a dust buildup is observed,
it is necessary to thoroughly clean the inside of the bench and canopy.

1

Remove the acrylic shields and lamps.

2

With a soft cloth, wipe the entire length of each lamp.

3

Clean both sides of the acrylic shields with a non-ammonia dis-
infectant cleaner.

4

Wipe the reflectors with a clean damp cloth.

5

Re-install the lamps and acrylic shields.

Mechanical Inspection

Inspect the unit’s mechanical integrity every 400-500 hours of use.

• Inspect the unit’s fasteners verifying that all are firmly in place.

Pay particular attention to the hinge bolts.

• Inspect gas springs for signs of wear. Replace gas springs that will

not hold the canopy in the full open position when raised.

• Inspect the AC power cord and its connections.
• Inspect the acrylic. Replace if broken, cracked or badly scratched.

Hour Counter

This sunbed incorporates an ingenious hour counter function into the
timing circuitry. It allows the operator of the unit to monitor the hours
of use of the lamps, making it easy to determine when to change them.
You may also decide to use this function to monitor other time based
maintenance tasks.

To determine how many hours the unit has been in service (since the
last reset of the hour counter memory), first make sure the timer dis-
play shows “0”. Then simply hold the stop button for three seconds.
The display will show two pairs of numbers which indicate the num-
ber of hours of service, then return to “0”. (example: Display shows 08
then 54. This equals 854 hours.) NOTE: If the unit is connected to a T-
Max® remote device, it may briefly lose communication with the
remote. This is normal.

To erase the indicated hours disconnect power from the sunbed. Press
and hold the green timer button as you reconnect power. Release the
button after a few seconds.

Removing/Replacing Lamps

1.

Grasp a lamp at one end and at the middle, then turn the lamp a
quarter turn. The lamp may then be gently removed from its holder.

2.

To reinstall lamp, insert pins on the ends of the lamp into the slots
on top of the lamp holder and turn the lamp a quarter turn.

Page 6  -  26713-01A

Replacing Lamps

To be assured of maximum tanning effectiveness, change lamps after
approximately 800-1000 hours of use. Tanning will continue after this
time but at a slower rate. To ensure trouble-free operation of your
sunbed, replace the lamp starters whenever the lamps are replaced.
We recommend using the lamps specified in the Safety Information.
Use of uncertified lamps is a violation of Federal regulations and will
void your warranty.

Removing/Replacing Acrylic Shields

The acrylic shields are secured in place by hinged profiles which run
the length of the bed, both front and back. Simply pry up on the inside
edge of the profile until it releases its latching action (see figure
below). Continue to pry up the profile across its entire length until it
swings back freely. Repeat for the other profile. The long edges of the
acrylic shield are now exposed. Standing in front of the sunbed, grasp
the long exposed edge of the acrylic and carefully slide it toward you
until it is removed.

After changing the lamps, replace
the acrylic shields by reversing
the above directions. Close
the hinged profile by push-
ing it back into place until it
snaps tight.

PROFILE

CAUTION

Be careful. The edges of the
acrylic shield may be sharp.

Start pulling from the

middle of the profile!

Содержание 24 X-Power

Страница 1: ...hildren the elderly or fair skinned people who always burn easily and either never tan or tan minimally should not use this equipment To use lie down on bench and pull canopy down as far as adjustment...

Страница 2: ...isible damage Report the extent of any damage to the transportation company In addition to the hex wrench supplied in the hardware kit you will need a 2 Phillips screwdriver Allen head Bolt 5 16 x 1 Q...

Страница 3: ...led Your sunbed will not operate without either the bypass plug or a remote system connected If remote operation is desired see Remote Connections 13 Place the bushings into hinge brackets 6 26713 01A...

Страница 4: ...ided with your remote system to determine if it operates in this way To connect your sunbed to this type of system a remote interface kit is required Contact your place of purchase to obtain the kit F...

Страница 5: ...ps will turn on and the timer will begin to count down If a tan ning time less than the displayed time is desired repeatedly press the timer button B to decrease the remaining time 2 Lift the canopy l...

Страница 6: ...two pairs of numbers which indicate the num ber of hours of service then return to 0 example Display shows 08 then 54 This equals 854 hours NOTE If the unit is connected to a T Max remote device it ma...

Страница 7: ...ll not stay fully open when raised 1 Raise and lower the canopy a few times to lubricate gas spring internal seals 2 Replace gas springs Problem Troubleshooting Solution My bed won t work with the T M...

Страница 8: ...es do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you No one has authority to change or modify this Limited Lifetime Warranty in any respect T...

Отзывы:

Похожие инструкции для 24 X-Power