HSC86AInstruction manual of hybrid servo driver
13
86-120
OFF
OFF
Adapt to our 86
series 12NM closed
loop motor
五、Protective function
1)Overvoltage protection
When the input voltage of HSC86A is higher than 90VAC, the driver will stop working.
At this time, the fault must be eliminated and reset after power on again.
2)Undervoltage protection
When the input voltage of HSC86A is lower than 15VAC, the driver will stop working. At
this time, the fault must be eliminated and reset after power on again.
3)Overcurrent protection
When overcurrent occurs in HSC86A, the driver will stop working. At this time, the fault
must be eliminated and reset after power on again.
4
)Tracking error
When the tracking error exceeds the tolerance of HSC86A, the driver stops working. At
this time, the fault must be eliminated and reset after power on again.
六、common problem
1.Common problems and solutions in the application