2400w PORTABLE GENERATOR
SMK35GEN
7. DC BATTERY CHARGING FUNCTION
This function is applicable to 12V battery charging only.
Disconnect the leads from the battery.
Loosen the vents on the battery.
Make sure the battery fluid level is correct
Using a hydrometer measure the specific gravity of the
battery fluid and calculate the charging time in
accordance with the table shown in Fig 12.
Attach the 12v charging leads to the battery observing
correct polarity (Red = + Positive) (black = - Negative).
Plug the 12v charger lead into the socket on the
generator (Fig 13).
The specific gravity for the fully charged battery shall be
within 1.26 to 1.28. It is advisable to check the specific
gravity every hour.
Fig 13
Fig 12