(Routine Preventive Maintenance, continued)
T
T
T
TYPICAL ROUTINE MAINTENANCE PROCEDURE
YPICAL ROUTINE MAINTENANCE PROCEDURE
YPICAL ROUTINE MAINTENANCE PROCEDURE
YPICAL ROUTINE MAINTENANCE PROCEDURE
I.
I.
I.
I.
Familiarization
Familiarization
Familiarization
Familiarization
Before beginning on the following checklist, ensure that you
understand how the compactor is supposed to operate. The normal
operating sequence of the compactor is as follows:
A. Enter correct code in keypad (if so equipped), enabling the
compactor controls for about 3 minutes.
B. With load door closed and STOP button pulled out, press
START button.
C. If the controls get a signal from the top limit switch
indicating that the compaction platen is correctly at its
top position, the compactor will start and the compaction
platen will descend.
D. When the compaction platen reaches the bottom of its
compaction stroke, it should trip the bottom limit switch,
which will signal the controls to reverse direction. The
compaction platen will then ascend to its top position, trip
the top limit switch, and shut down. If there is still time
left on the timer, pressing the START button will cause
the compaction platen to begin another cycle.
E. If the compaction platen descends and meets enough
resistance from waste material that it cannot reach the
bottom limit switch, hydraulic pressure will build until
the hydraulic pressure switch signals the controls that
the container bin is getting full and will shut the
compactor off with the compaction platen in its down
position.
F. If the down-and-up cycle of the compaction platen is
interrupted by pressing the STOP button, by opening the
loading door, by the timer expiring, or by the pressure
switch signaling that the bin is getting full, then the next
time you enter the correct code in the keypad and start
the compactor with the START button, the compaction
platen will ascend to its top position, trip the top limit
switch and shut down.
3.6