FOR USER

 

SYMBOL 

DESIGNATION

 

OPERATION 

 
 

Power ON/OFF 

Press to power on or off the heat pump 

 
 

Up/ Down 

Press to set desired water temperature 

 

Heat/Cool/Auto 

Press to shift among cooling, heating and auto   

 

Fan 

Press to select Silence mode ON/OFF 

 

Note:   

 

You may set the desired water temperature from 12 to 40

.   

 

The 

  on the right shows the inlet water temperature. The 

  on the left shows the outlet 

water temperature.   

 

After you turn on the heat pump, the fan will start to run in 3 minutes. In another 30 seconds, 

the compressor will start to run.   

2.2.1    Status on the display 

 

  Auto Mode 

  Defrost Mode 

Heating Mode 

  Cooling Mode 

  Timer ON/OFF   

2.2.2.    Time setting 

 

Press 

  for 5 seconds to enter time setting. 88:88 is flashing on the display 

 

Press 

  and 

  to adjust the time (fast adjusting by continuous pressing). Then, press 

 

to confirm and exit. 

 

In the time setting mode, if no operation for 30 seconds, the previous pressing will be lost and 
exit automatically. 

2.2.3.    Timer on and off 

 

Press the 

 

for 10 seconds to enter the timer setting. The “ON” will be flashing to enter the 

Timer ON setting. Press the 

 

and 

  to adjust Timer ON time. You can choose Timer on 

( Display: ON ), or Repeat Timer ON ( display: 1 ON ) by pressing 

. Then press 

  to confirm 

 

When the “ON” stops flashing, and “OFF” is flashing, you enter the Timer OFF mode. Press the 

 

and 

  to adjust Timer OFF time. You can choose Timer OFF (Display: OFF ), or Repeat 

Timer OFF ( display: 2 OFF ) by pressing 

. Then press 

 

to confirm 

Содержание 100Fi

Страница 1: ...Thank you for choosing Full inverter pool heat pump INSTALLATION USER MANUAL ...

Страница 2: ......

Страница 3: ...e before installation 10 2 2 Installation instruction 11 2 3 Trial after installation 14 2 4 Maintenance and winterizing 14 3 TROUBLE SHOOTING FOR COMMON FAULTS 15 4 FAILURE CODE 16 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 17 APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 18 APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 19 PLEASE READ IT CAREFULLY AND KEEP IT FOR SUBSEQUENT U...

Страница 4: ...se a Any maintenance work on the heat pump must be carried out only by a qualified Service Technician b Do not place put items on the heat pump c Do not block air outlet of the heat pump 2 Installation a This product must be kept away from any source of fire b The installation can t be in a closed environment or indoors and must be kept well ventilated c Vacuum completely before welding any mainte...

Страница 5: ... pump during transportation c The product must be kept away from any source of fire d Storage place should be well ventilated 4 Maintenance Notice a For repair or scrap please contact a qualified Service Technician for advice b Qualification requirement Only qualified Service Technicians are permitted to carry any service work on heat pump c Repairing or filling refrigerant R32 may only be carried...

Страница 6: ...erating conditions and range ITEMS RANGE Operating range Air temp 7 43 Temp setting heating 18 40 cooling 12 30 The heat pump will have ideal performance in the operation range Air 15 25 1 3 Advantages of different modes The heat pump has two modes Smart and Silence They have different advantages under different conditions ...

Страница 7: ...the heat pump to avoid the titanium heat exchanger damage 1 4 3 Don t put obstacles in front of the air inlet and outlet of the heat pump Otherwise heating efficiency will be sharply reduced even stopping the system 1 4 4 Do not put anything into inlet or outlet do not remove fan cover MODE RECOMMENDATION ADVANTAGES Smart mode As standard Heating capacity 20 to 100 capacity Intelligent optimizatio...

Страница 8: ...tances occurred e g abnormal noises smells smokes and leakage of electricity switch off the main power immediately and contact your local dealer Do not try to repair the heat pump by yourselves 1 4 7 The main power switch should be out of the reach of Children 1 4 8 Cut off the power in a lightning storm power surges can damage heat pumps ...

Страница 9: ... Abnormal outdoor power supply 2 OPERATIONS 2 1 Notice before using 2 1 1 The user is advised to start the water pump before the heat pump and turn off the heat pump before the water pump for long life circle 2 1 2 Check firstly for any water leakage of piping connection then power on press the ON OFF button of the heat pump and set suitable temperature 2 2 Operation instructions ...

Страница 10: ... Timer ON OFF 2 2 2 Time setting Press for 5 seconds to enter time setting 88 88 is flashing on the display Press and to adjust the time fast adjusting by continuous pressing Then press to confirm and exit In the time setting mode if no operation for 30 seconds the previous pressing will be lost and exit automatically 2 2 3 Timer on and off Press the for 10 seconds to enter the timer setting The O...

Страница 11: ...ost needs to be more than 30 minutes The symbol of defrost is twinkling when machine is compulsory or auto defrost The period and ending of compulsory defrost is the same as auto defrost 2 3 Daily maintenance and winterizing 2 3 1 Daily Maintenance Please don t forget to cut off power supply of the heat pump Please clean the evaporator with household detergents or clean water NEVER use gasoline th...

Страница 12: ... 5 5 5 6 8 7 7 9 8 12 1 12 1 16 4 Rated input power kW at air 15 C 0 17 1 2 0 19 1 5 0 22 1 73 0 27 2 2 0 3 2 6 0 38 3 3 0 57 3 8 0 53 3 9 0 62 5 2 Rated input current A at air 15 C 0 74 5 2 0 83 6 5 0 96 7 52 1 17 9 6 1 3 11 3 1 65 14 3 2 48 16 5 0 76 5 6 0 89 7 4 Power supply 230V 1 Ph 50Hz 400V 3 Ph 50Hz Advised water flux m h 2 4 3 4 4 6 5 7 6 5 8 5 8 10 10 12 10 12 12 18 Sound pressure 1m dB ...

Страница 13: ...TALLATION AND MAINTENANCE The heat pump must be installed by a professional team The users are not qualified to install by themselves otherwise the heat pump might be damaged and risky for users safety 2 1 Notice before installation 2 1 1 The inlet and outlet water unions can t bear the weight of soft pipes The heat pump must be connected with hard pipes 2 1 2 In order to guarantee the heating eff...

Страница 14: ...ND PROFESSIONALS 2 2 Installation instruction 2 2 1 Location and size The heat pump should be installed in a place with good ventilation The picture can t be displayed MINIMUM DISTANCE Filter Water processor Water switch ...

Страница 15: ...ecting devices and cable specification Connect to appropriate power supply the voltage should comply with the rated voltage of the products Well earth the heat pump Wiring must be connected by a professional technician according to the circuit diagram Set breaker or fuse according to the local code leakage operating current 30mA The layout of power cable and signal cable should be orderly and not ...

Страница 16: ...mmerwave 210Fi Summerwave 270Fi Summerwave 270Fi Summerwave 350Fi Breaker Rated Current A 10 5 12 0 14 5 16 5 18 0 21 0 24 0 9 0 12 0 Rated Residual Action Current mA 30 30 30 30 30 30 30 30 30 Fuse A 10 5 12 0 14 5 16 5 18 0 21 0 24 0 9 0 12 0 Power Cord mm2 3 2 5 3 2 5 3 2 5 3 2 5 3 4 3 4 3 6 5x2 5 5x2 5 Signal cable mm2 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 NOTE The above data i...

Страница 17: ...leakage of water Power on and press the ON OFF button of the heat pump and set desired temperature in the thermostat In order to protect the heat pump the heat pump is equipped with start delay function When starting the heat pump the fan will start to run in 3 minutes in another 30 seconds the compressor will start to run After pool heat pump starts up check for any abnormal noise from the heat p...

Страница 18: ...he breaker Fan running but with insufficient heating evaporator blocked Remove the obstacles Air outlet blocked Remove the obstacles 3 minutes start delay Wait patiently Display normal but no heating Set temp too low Set proper heating temp 3 minutes start delay Wait patiently If above solutions don t work please contact your installer with detailed information and your model number Don t try to r...

Страница 19: ... cooling mode 7 P0 Controller communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp sensor failure 12 P5 Gas return temp sensor failure 13 P6 Cooling coil pipe temp sensor failure 14 P7 Ambient temp sensor failure 15 P8 Cooling plate sensor failure 16 P9 Current sensor failure 17 PA Res...

Страница 20: ...17 FOR INSTALLERS AND PROFESSIONALS APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Страница 21: ...18 FOR INSTALLERS AND PROFESSIONALS APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Страница 22: ...19 FOR INSTALLERS AND PROFESSIONALS APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Страница 23: ... with filtration clock A Water pump timer B Water pump wiring of Heat Pump Note The installer should connect A parallel with B as above picture To start the water pump condition A or B is connected To stop the water pump both A and B should be disconnected ...

Страница 24: ...Thank you for choosing Full inverter Pool heat pump Version Cb9Ir32 ...

Отзывы: