3
2. Safety information
Please read these instructions carefully before using the heat pump and keep them for future reference:
1. Always keep the unit upright. If the unit has been tilted or put on its side, wait 24h before starting the heat
pump.
2. Put the unit on a flat, solid base.
3. Do not drop the heat pump.
4. The heat pump must always be installed outdoors.
5. Check if the voltage indicated on the RCD of the heat pump corresponds to the local mains voltage before
you connect the unit.
6. Do not pull the mains plug with unnecessary force. Do not wrap the mains plug around the heat pump.
7. Do not use the heat pump in combination with a transformer.
8. If the heat pump is damaged during transportation, it must be replaced, please contact your service centre or
similarly qualified persons in order to avoid a hazard.
9. Always make sure the water connections of the heat pump are properly locked before you start using the
machine.
10. Never insert objects directly into the fan, as this will cause it to become blocked and damaged.
11. The evaporator fins must not be damaged.
12. This heat pump is not intended for use by persons with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the
heat pump by a person responsible for their safety.
13. Children should always be supervised to ensure that they do not play with the heat pump.
14. Disconnect the mains plug from the socket when the heat pump is not in use and before cleaning.
The heat pump will always perform very well, provided the following elements are present
1. Fresh air
2. Electricity
3. Swimming pool water
3. Specifications
Min. operating air temperature (°C)
10
Fan direction
horizontal
Heating Capacity A: 27°C/ W: 26°C * (kW)
3,35
Noise at 2m (dB(A))
55
Heating capacity A: 15°C/ W: 26°C(kW)
2,65
Refrigerant
R32
Power input(kW)
0,56
Refrigerant weight (kg)
0,24
COP at A25/W25(C.O.P)
6
condensor
titanium
COP at A15/W25(C.O.P)
5,1
Water connection (mm)
32
Maximum pool volume(
m³)
12
Nominal water flow (
m³/h)
2
Running Current(A)
2,55
Shipping dimensions(mm)
310/360/385
Max Running Current(A)
3
Unit Net dimensions(mm)
290/310/370
Power Supply (V/f/Hz)
230v/1/50Hz
Net/Shipping weight(kg)
15
Air flow (
m³/h)
700
*Measuring conditions: Outdoor air temp: 25°C, Inflowing water temp: 25°C, rel. humidity: 65%.
ENG