background image

 

©  2019 Sunman (Zhenjiang) Co., Ltd. All rights reserved. Specifications included in this manual are subject to change without notice. 

www.sunman-energy.com 

version 2019A      page8 / 18 

TM 

 

 

 

 

 

 

 

 

a.

 

Confirmation of material of color steel 

 

SMD  Series  to  be  bonded  with  PE((Use  of  the  brand:  BECKER,  VALSPAR,  NIPPON,  AKZO  NOBEL) 

coating  of  zinc  aluminum  plate(Galvalume.  AZ50,  AZ55,  AZ60  or  Zincalume.  AZ150).  Substrate 

materials not listed in the table must be approved by the local distributors, otherwise the warranty 

will be invalid. 

b.

 

Size of color steel roofing: 

 

 
 

 

 

 

c.

 

Preparation of bonding material 

 

Please contact the local distributors for the detail information. 

 

d.

 

Clean the color steel roofing 

 

Always keep the backsheet of SMD Series and rooftop clean before install. 

 

e.

 

Install chemical bonding material 

 

The thickness of 

chemical bonding material should

 not less than 4 mm, width is not less than 10 mm. The 

length  of  the 

chemical  bonding  material 

shall  not  be  less  than  the  number  corresponding  to  L  in  the 

Confirmation of 

material of color steel 

 

Measure the size of 

color steel roofing 

Preparation of 

bonding material 

Clean the color steel 

roofing 

Installation

 

Install chemical 

bonding material 

Max Span=380mm 

Max Span=380mm 

Min Span=15mm 

Min Span=15mm 

Min Span=20mm 

Содержание eArche PV System

Страница 1: ...eArche PV System Installation Manual TM...

Страница 2: ...his guide Features Benefits Notices General safety Handling safety Installation safety Fire safety Production Identification Mechanical Installation Grounding Electrical installation Disclaimer of lia...

Страница 3: ...on For any questions please contact SUNMAN s Customer Service Department or our local representatives for more detailed information Installers should follow all safety precautions described in this gu...

Страница 4: ...sunman energy com version 2019A page2 18 TM Features Benefits Flexible layouts eArcheTM PV system can be installed at any shape roofs which has integrated appearance with buildings Maximization insta...

Страница 5: ...equired for eArcheTM PV System PV arrays Copyright and Trademark Information Copyright 2019 by Sunman Zhenjiang Company Limited All rights reserved eArche and the SUNMAN logo are trademarks of Sunman...

Страница 6: ...esigned for outdoor use eArche can be ground mounted mounted on rooftops vehicles or boats The proper design of support structures lies within the responsibility of the system designers and installers...

Страница 7: ...ensure that the front cover faces down on a soft flat surface to prevent water from collecting inside the panel and causing damage to exposed connectors Installation safety Never open electrical conn...

Страница 8: ...pment or in places where flammable gases may be generated eArche have been rated Fire Class C and are suitable for mounting on to a Class A roof Production Identification Each eArche has two labels pr...

Страница 9: ...ion any roof penetration required to mount eArche must be properly sealed to prevent leaks Dust building up on the surface of eArche can impair with eArche performance SUNMAN recommends installing eAr...

Страница 10: ...teel roofing c Preparation of bonding material Please contact the local distributors for the detail information d Clean the color steel roofing Always keep the backsheet of SMD Series and rooftop clea...

Страница 11: ...A page9 18 TM following table eArche SMDxxxM 4X12DW SMDxxxM 4X12UW SMDxxxM 4X09DW SMDxxxM 4X09UW SMDxxxM 6X12DW SMDxxxM 6X12UW SMDxxxM 6X10DW SMDxxxM 6X10UW L 665mm 995mm f Layout of SMD Series Layout...

Страница 12: ...llation For SMA Series SMAxxxM 6X12DW SMAxxxM 6X10DW SMAxxxM 4X12DW SMAxxxM 4X09DW SMAxxxM 6X12UW SMAxxxM 6X10UW SMAxxxM 4X12UW SMAxxxM 4X09UW Clamps can be used for the connection of SMA series compo...

Страница 13: ...ect to change without notice www sunman energy com version 2019A page11 18 TM Layout For SMA Series SMAxxxM 6X12DW SMAxxxM 6X10DW SMAxxxM 4X12DW SMAxxxM 4X09DW SMAxxxM 6X12UW SMAxxxM 6X10UW SMAxxxM 4X...

Страница 14: ...use a recommended connector type for the grounding wire For grounding this guide refers to module frame grounding If grounding is required make sure module frames metal exposed to touch are always gr...

Страница 15: ...Sunman Zhenjiang Co Ltd All rights reserved Specifications included in this manual are subject to change without notice www sunman energy com version 2019A page13 18 TM For SMA Series Grounding layout...

Страница 16: ...stainless steel The star washer is fitted directly under the connection terminal and makes electrical contact by penetrating the anodized coating of the aluminum frame see the pictures below Recommend...

Страница 17: ...han two strings in parallel if eArche without any fuse or blocking diode to be connected according to the maximum series fuse rating of eArche and local electrical installation code There is no limita...

Страница 18: ...herence to this manual and the conditions or methods of installation operation use and maintenance of photovoltaic PV products are beyond SUNMAN s control SUNMAN does not accept responsibility and exp...

Страница 19: ...4X09DW 165 18 9 8 74 23 5 9 28 1503mm X 689mm X 5 6mm 3 7kg SMD160M 4X09DW 160 18 6 8 61 23 2 9 17 1503mm X 689mm X 5 6mm 3 7kg SMDxxxM 6X12UW SMD355M 6X12UW 355 39 5 8 99 48 1 9 51 2007mm X 1019mm X...

Страница 20: ...mm 5 0kg SMA160M 4X09DW 160 18 6 8 61 23 2 9 17 1479mm X 665mm X 35mm 5 0kg SMAxxxM 6X12UW SMA355M 6X12UW 355 39 5 8 99 48 1 9 51 1983mm X 995mm X 35mm 9 0kg 20A 16 SMA350M 6X12UW 350 39 2 8 93 47 9 9...

Отзывы: