19
5 Installation
T
he safety instructions in the previous sections must be observed!
5.1
Installation RW / RCP
Care must be taken that the connection cables are positioned that they cannot get caught up in the
propeller blades and that they are not subjected to tension.
The electrical connection is carried out in accordance with section 5.7 Electrical connection.
NOTE
We recommend that Sulzer installation accessories be used for the installation of the
RW / RCP.
5.2
Tightening torque
Tightening torque for Sulzer stainless steel screws A4-70:
Thread
M6
M8
M10
M12
M16
M20
M24
Tightening torque
6.9 Nm
17 Nm
33 Nm
56 Nm
136 Nm
267 Nm
460 Nm
5.2.1 Nord-Lock
®
washer
1176-00
Figure 10.
Correct fitting position of the Nord-Lock
®
securing washers