1.
Characteristics of the shutter sensors :
ILS (Reed switch) sensor : The magnet attracts the reed
every time it passes before the sensor and establishes
the contact.
The indicators
on the
HOME
page
make it possible to check the opening and closing of the
shutters.
Sensor reference : 083912
2.
Checking a sensor :
The magnet is facing the sensor, check the continuity => R
100 Ω (between the blue and the brown wires)
The magnet is no longer facing the sensor (open contact) => No continuity
On assembly, the air-gap must be 5 mm max. The tip of the sensor must be allowed to jut out by 1 to 2 cm.
Note :
The sensors are also used for counting the closures of the shutters in order to trigger the initialization of
the application rate actuators and of the chutes every 15 closures