DX - ISOBUS
W
EIGHING DEVICE SENSOR
C6.2
N
AME
:
T
RAINING
D
EPARTMENT
D
ATE
:
2019.09
P
AGE
:
19/55
R
ÉFÉRENCE
:
T
ECHNICIAN
O
PERATING
M
ANUAL
DX
ISOBUS
I
ND
01
4.
Weighing device sensor check :
Checking the weighing device sensor is only carried out after a positive diagnosis of the link between the CAN
and ECU and a weight indicator supply voltage.
a)
When checking the sensor the spreader must be
unhitched.
b)
Place a nut on the pressure screw ① to
compress the spring so there is no strain on the
weighing beam.
c)
Completely disconnect the weight indicator in
the connection box ② and uncouple the grey
wire from the blue wire
d)
Check the values opposite. The weighing device
sensor is considered to be compliant if it meets
all these indications.
B
RAND SENSOR
V
ISCHAY
R
BETWEEN THE BROWN
AND BLUE WIRES
385
Ω
+/- 10
R
BETWEEN THE GREEN
/
YELLOW AND BLACK WIRES
353
Ω
+/- 3
R
BETWEEN THE GREY WIRE
AND EACH OF THE
4
OTHER
WIRES
N
O CONTINUITY