GB
Machine components
1
Spindle
2
Right angle gear head
3
Water connector
4
Screw
5
Wrench 2 mm
6
Safety lever throttle
7
Ring throttle
8
Exhaust Hose
9
Muffler
10
Air hose
11
Wrench 22 mm
12
Wrench 17 mm
Adaptor kit
13
Handle extension
14
Hexagon nut
15
Side handle
Technical Data LXE 3 DH
at 90 PSI Operating Pressure
without oil
with oil
Power
550
600
Watt
Torque
~6,5
~7
Nm
Air consumption
31,5
31,5
cfm
full load
0,9
0,9 m
3
/min
Air consumption
36,7
36,7
cfm
no load
1,05
1,05 m
3
/min
No load speed
2'500
3'000
rpm
Sound pressure level
according to CEN/TC 255
80 dB(A)
Vibration according to
ISO/DIS 8662-4
with test disc dia 100 x 25
<2,5m/s
2
Weight without hose
1,5 kg
Recommended air quality
accord. to ISO/DIS 8573-1
3/4/4
Air hose ID
9,5 mm/3/8"
Grinding/Cutting wheels
150 mm/6"
(refer to APT catalog)
Spindle thread
M 14 or
5/8"-11
Recommended Accessories
16
Coupling with min ID 7 mm/ 9/32"
17
1/2" -Service Unit ( Capacity 5-8
Micron). with wet air include
Lubricator
Suitable Tools:
18
Elastic support plate with bayonet
fitting
21
19/20
Surface grinding wheels / Grinding
rings / Grinding cups / Diamond tools.
Additional Abrasives and Tools
can be found in the the SUHNER catalogs
Air supply requirements:
The ISO/DIS quality specifications require, that
air is free of solid particles larger than 5
micron, remaining water content to be max. 6
g/m
3
(pressure dew point +3 degree C) and
air may contain 5 mg/m
3
of oil. Therefore
please observe the following:
Operating with dirty and unlubricated air
reduces tool life substantially.
Before installing extension hoses, blow them
clean and minimize , if at all necessary
coupling and keep them clean.
Rust will occur, if air supply is not lubricated
and wet. A few drops of air tool oil from time to
time will prevent rust and stops bearings from
seizing.
Conserve:
Put some drops of oil in the air inlet and briefly
blow through.
Safety Instructions:
Do not exceed max. operating speed of tool
and clamping element.
Observe accurate mounting of insert tools.
Observe mounting instructions for Mounted
Stones!
Run tool for a couple of seconds under no
load, replace vibrating insert tools at once,
protect mounted points from knocks and
grease.
Secure work, use clamps or a vise to hold
work.