background image

Insert the “key” of the arm into the arm fixing plate. The main body must be placed 

at 90 degrees angle  against the fixing angle.

 

 

 

 

 

 

 

Turn the main body 90 degrees and insert the center gear of the mounting plate to 

the hole of the main body.

 

 

 

Fix the main body with the bind screw.

Step 2 - Install the Main Body

Step 3 - Adjustment and Operation

If the lid stay is sagging (A), turn the adjustment screw(Z) at the 

base of the arm until the lid stay straightens (B). The lid can then

be closed by pushing down gently on the lid. When the lid is 

closing, do not put additional pressure on the lid (to close more 

quickly, etc.) as it may damage the stay. If you have difficulty with

operation or adjustment of the lid stay, please contact Sugatsune

for technical assistance.

(A)

(B)

Screw (Z)

Door

Height

(inch)

Door Weight(lbs)

Min

Max

10

14.0

24.0

11

12.7

21.8

12

11.7

20.0

13

10.8

18.5

14

10.0

17.1

15

9.3

16.0

16

8.8

15.0

17

8.2

14.1

18

7.8

13.3

19

7.4

12.6

20

7.0

12.0

21

6.7

11.4

22

6.4

10.9

23

6.1

10.4

24

5.8

10.0

25

5.6

9.6

Door Weight Range

Per pair, in Lbs

8

17.5

30.0

9

15.6

26.7

Height

Weight and Door Height

The SDS-C301 must be used 

taking the weight and door 

height into consideration. 

The table indicates the usable 

weight range per door height 

when using two stays. When 

using one stay, the weight 

range will be half of what is 

shown.

For doors outside of the 

recommended weight range,

please contact Sugatsune for 

the recommended lid stay.

Remarks

• 

 Do not attempt to disassemble or modify the lid stay as serious damage and/or injury may 

    occur.

•  For extreme environments(high temperature, humidity, etc.), please contact Sugatsune for 

    technical assistance before installation.

•  The product has been develop for use as a lid stay - other applications are not recommended. 

Sugatsune America, Inc.

18101 Savarona Way

Carson, CA 90746-1411

SDS-C301N Installation

For Upward Opening Door

90

Step 1 -  Position and Install Mounting Plates

The hinge type and the coverage affect the placement of the mounting plate and arm 

fixing plate. Please use the corresponding diagram on page 2 to determine the mounting 

dimensions for your application.  Position and install mounting plate and arm fixing plate 

using supplied screws.

For installation of the mounting plate on the right hand side, 

the arrow of  “R”  on the “US” side should point upward 

vertically. For the left side, the arrow of  “L” on the “US” side 

should point upward vertically.

All diagrams are shown for right side mounting.

Before installation, please check the Door Weight Range Table to determine 

if the SDS-C301N is the correct stay for the size and weight door. 

26

5.4

9.2

Toll Free (800) 562-5267 

(310) 329-6373  Fax (310) 329-0819

www.sugatsune.com

Page 1 of 2

081010SDSC301UP

Содержание SDS-C301N

Страница 1: ...wo stays When using one stay the weight range will be half of what is shown For doors outside of the recommended weight range please contact Sugatsune for the recommended lid stay Remarks Do not attempt to disassemble or modify the lid stay as serious damage and or injury may occur For extreme environments high temperature humidity etc please contact Sugatsune for technical assistance before insta...

Страница 2: ...32mm Arm Fixing Plate Mounting Plate Door Side Board Top Board Door Arm Fixing Plate 3 13 16 97mm Top Board Hinge Center Inset Single Knuckle Piano Butt etc Hinge 3 4 19mm Overlay Concealed Hinge Euro Hinge Installation Overlay Single Knuckle Piano Butt etc Hinge 13 32 Overlay 10 5mm Overlay Door Side Edge 13 32 Overlay 10 5mm Overlay Door Side Edge Upward Opening Doors Top Board Door 3 4 Top Boar...

Страница 3: ... SDS C301 must be used taking the weight and door height into consideration The table indicates the usable weight range per door height when using two stays When using one stay the weight range will be half of what is shown For doors outside of the recommended weight range please contact Sugatsune for the recommended lid stay Remarks Do not attempt to disassemble or modify the lid stay as serious ...

Страница 4: ...unting Plate E G D Opening angle 80 90 5 29 64 138 5mm 100 5 1 16 128 5mm 4 25 32 121 5mm A 1 9 32 32 6mm B 1 21 64 33 9mm 1 5 16 33 2mm 2 15 64 56 8mm D 2 13 64 56 1mm 2 17 64 57 4mm G E 3 47 64 94 8mm 3 17 64 83 1mm 2 61 64 75 2mm 4 1 4 107 9mm 3 57 64 98 9mm 3 21 32 92 8mm 13 32 10 5mm 1 17 64 32mm Arm Fixing Plate Door Side Board Top Board Door Arm Fixing Plate Top Board Hinge Center 3 4 19mm ...

Отзывы: