15
【
4
】
Gap between door and cabinet still remains
Overview:
This system controls the slant of the door by
bowing the Connecting pipe.
Simply try the following method unsuspectingly.
Release the stress on Connecting pipe by
loosening the 4 pcs of Hexagon socket head
cap screws.
*Also, loosen Door close position adjuster
screw A and B, so that it make a clearance
between the Upper arm and the Connecting
pipe.
*Adjustment need to be done from inside the
cabinet at the closed door.
Gap at the top
Gap at the bottom
Arm connecting pipe
Hexagon socket
head cap screw
M6X35
Pipe clamp
Lower arm
Tightening torque:11-13 N m
Hexagon socket head
cap screw
B
M6×35
Hexagon socket head
cap screw
A
M6×35
Arm connecting
pipe
Hexagon socket
head cap screw
M6X35
Tighten
Tighten after
the adjustment
Loosen
Tighten
Tighten after
the adjustment
Loosen
In case the gap still remains, even if the Connecting pipe is 7 or 8 mm apart from Upper arm, once loosen the Door
position adjuster screw A and B completely, then tighten them until the Connecting pipe touches Upper arm. (See
EHORZ¿JXUH
Hexagon socket
headcap screw
A
M6×35
Hexagon socket
headcap screw
B
M6×35
Cross section C-C
C
C
Tighten the Hexagon socket head cap screws on Lower arm.
Adjustment would not be achieved if the screws on Lower arm were
loose.