Installation scheme
Avoid any feed pipe connection! If absolutely necessary, protect the feed line with a heating cable.
Observe DIN 1988 / DIN EN 1717 and local norms.
By-pass line
height differ
ence max. 5 m
Not included in the scope of delivery
pos. 10
2x Residual-Current Device 230 V, 0,03 A
pos. 11,11a Lock valve
pos. 12
Shut-off valve for manual ventilation
pos. 13
Insulation material, min. thickness 30 mm
pos. 14
Bite protection
pos. 15
Drain cock
pos. 16
SUEVIA Drinking Bowls
pos. 17
Flow control Ref.101.0309
pos. 18
Filter
pos. 20
Alarm system for water circuits (Ref. 101.0308)
Start of operation
1. Main switch in
0 = OFF
position (pos. 9)
2. Fill water circuit with water
3. Bleed the heating unit (pos. 1), the pump (pos. 2) and the water circuit over the shut-off valve for manual ventilation
(pos. 12)
.
Check that by-pass line is closed and that water circuit runs through the heating unit!
4. Remaining air bubbles will automatically escape through the automatic vent valve (pos. 7)
5. Main switch to
1 = ON
position (pos. 9)
6. Circulation pump is switched on. Heating element is ready to work.
7. Repeat point 3.
Attention: when bleeding, hot water can escape!
8. Adjust the necessary return flow temperature at thermostat (pos. 4). Factory adju10°C. Control-light at the
heating element illuminates only if the heating element is heating.
Delivery scope
pos. 1
Heating unit
pos. 2
Circulation pump 230 V
pos. 3
Non-return valve for water connection
pos. 4
Adjustable thermostat
pos. 5
Non-return flap
pos. 6
Pressure relief valve 6 bar
pos. 7
Automatic vent valve
pos. 8
Security thermostat (fixed adjustment)
pos. 9
Controller
pos. 23 Heating element
9
23
13
13
230V
11
8
6
10
1
15
2
11
3
18
11
13
4
5
13
20
13
14
16
16
17
13
40 C°
40 cm
230V
10
12
7
11a
11a
13
14
13
14
stable
tempered room
optional