Page 32
Component Removal
Warming Drawer WWD30-2
4-9
#814750 - Revision A - January, 2011
Front Gasket Removal
NOTE
:
See all Warnings and Cautions at beginning of
Section.
1. Disconnect Electrical Supply to Unit.
2. Stainless steel drawer box must be removed from
drawer.
3. Remove drawer from unit. (
Page 4-3
)
4. Lift center slide assembly out of unit and set aside.
5. Remove (5) front collar screws and lift off collar.
(
Figure 4-24
) When collar is removed, reinstall top
two collar screws. (
See Figure 4-25
)
6. Remove (2) screws holding internal support channel
to top cover (See Figure 4-26), and then remove
front collar frame components. (
See Figure 4-27
)
7. Remove top cover screws and lift off cover. (
See
Figures 4-28 & 4-29
)
8. Remove (4) screws from front bottom of warming
drawer cavity. These must be removed to allow the
unit bottom cover to be flexed away from the cavity
to allow room for old gasket to be removed and new
gasket to be installed. (
See Figure 4-30
)
NOTE
:
When reassembling unit do not forget to install
screw support spacers. (See Figure 4-31 blow-up)
These provide necessary support to prevent dam-
age to front collar when installation screws are rein-
stalled.
Metal edges may be sharp. Use caution when
servicing unit to avoid personal injury.
ELECTRICAL SHOCK HAZARD - DISCONNECT
ELECTRICAL SUPPLY TO UNIT BEFORE ATTEMPT-
ING THE FOLLOWING PROCEDURES.
Figure 4-28. Top Cover Screws (top & side)
Figure 4-24. Front Collar Screws
Figure 4-27. Front Collar Pieces
Figure 4-25. Front Collar off Screws In
Reinstall top two
collar screws.
Figure 4-26. Top Cover to Support Channel Screws
Remove (2) support
channel screws
Do not loose (2) front collar screw spacers. They
will need to be reinstalled or frame will be damaged
when unit reinstalled.
Screw Spacers