Page 34
Troubleshooting
Troubleshooting
Microwave Drop-down Door Series
Microwave Drop-down Door Series
4-7
#826151 - Revision A - March, 2016
TEST
PROCEDURE
COMPONENT TEST
BROKEN 20 AMP FUSE
NOISE FILTER TEST
Perform 3E Checks (page 4-2)
1
If the 20 amp fuse is broken when the door is opened, check the primary
2
latch switch and monitor switch.
Replace defective switch(es) and 20 amp fuse.
3
Perform 4R Checks (4-2)
4
Perform 3E Checks (page 4-2)
1
Remove wires from noise filter board terminals
2
Use an Ohm meter to measure the resistance between:
3
a. N and L - read infinite resistance
b. N and White - read zero resistance
c. L and Red - read zero resistance
If incorrect readings are obtained, replace the noise filter
4
Perform 4R Checks (4-2)
5
FUSE 20A
NOISE FILTER
NOISE SUPPRESSION COIL
LINE CROSS CAPACITOR
0.22µF / AC 250V
LINE BYPASS
CAPACITOR
0.0033µF / AC 125V
LINE BYPASS
CAPACITOR
0.0033µF / AC 125V
L
RED
WHITE
N