background image

Door Panel

MODELS UC-24R AND UC-24C(I)

Models UC-24R and UC-24C(I) can be fitted with a

custom overlay or stainless steel door front panel. A stain-

less steel door panel with tubular or pro handle is available

as a sales accessory. Installation of the stainless steel

panel will be required.

For the overlay application, a decorative door panel and

handle hardware must be provided. Refer to the chart for

panel specifications.

You can match your handle hardware with surrounding

cabinetry or use a Sub-Zero accessory handle. Handles

must be attached directly to the overlay panel.

BEVERAGE CENTER MODEL UC-24BG

Stainless steel model UC-24BG/S is shipped from the

factory with the stainless steel door panel and tubular or

pro handle in place. No panel installation is required.

For overlay model UC-24BG/O, a decorative frame door

panel must be provided to surround the glass. The inside

edges of the panel that will be visible through the glass

must be finished. Refer to the chart for panel specifica-

tions.

You may also use your own handle hardware to match sur-

rounding cabinetry. If you do not use the pre-drilled holes

on the door of the unit, you will need to attach the handle

directly to the overlay panel.

IMPORTANT NOTE:

For installations at or above 5,000'

(1524 m) in altitude, a special high altitude glass door unit

must be ordered.

OUTDOOR MODEL UC-24RO

Model UC-24RO is shipped from the factory with the

stainless steel door panel and tubular or pro handle in

place. No panel installation is required.

IMPORTANT NOTE:

Model UC-24RO must be built into

cabinetry and cannot be used in a freestanding applica-

tion.

Undercounter Installation

9

subzero.com/specs

A solid panel must not be installed over the glass door,

as this may cause moisture to form behind the panel.

Panel Specifications

OVERLAY PANEL

W

H

UC-24R, UC-24BG, UC-24C(I)

23

3

/

4

"

(603)

30

1

/

16

"

(764)

RAILS AND STILES

W

UC-24BG

2

1

/

4

"

(57)

min

MAX PANEL WEIGHT

UC-24R and UC-24C(I)

20 lbs

(9 kg)

UC-24BG

10 lbs

(5 kg)

MIN PANEL THICKNESS

Overlay Panels

5

/

8

"

(16)

Содержание Uc24crh

Страница 1: ...INSTALLATION GUIDE Undercounter Refrigeration...

Страница 2: ...parentheses are millimeters unless otherwise specified Important Note To ensure the safe and efficient installation of Sub Zero equipment please take note of the following types of highlighted informa...

Страница 3: ...uring the installation By reading these instruc tions carefully you will make the installation process easier problem free and most importantly safe Any questions or problems regarding the installatio...

Страница 4: ...OPENING HEIGHT TOP VIEW FRONT VIEW SIDE VIEW OPENING DIMENSIONS 237 8 606 24 610 34 864 4 102 253 8 645 23 8 60 Undercounter Models OVERALL DIMENSIONS Specifications INTERIOR CAPACITY R CU FT L F CU F...

Страница 5: ...pening Allow enough clearance in front of the unit for full door swing TOOLS AND MATERIALS REQUIRED Appliance dolly able to support 130 lbs 59 kg Level 2 6 m and 4 1 2 m recommended Phillips and slott...

Страница 6: ...ntly Plumbing Requirements Water Supply Line 1 4 OD copper line Water Pressure 20 100 psi 1 4 6 9 bar Excess Water Line for Connection 26 660 min FRONT VIEW SHADED AREA EXTENDS 1 2 13 FROM BACK WALL 1...

Страница 7: ...rse the procedure to reinstall the shelf Undercounter Installation 7 subzero com specs Before moving the undercounter unit into position protect any finished flooring with appropriate materials and se...

Страница 8: ...he door panel extends out from surrounding cabinets approximately 1 4 6 WATER LINE CONNECTION MODEL UC 24CI For model UC 24CI connect the plastic tubing from the ice maker to the household water line...

Страница 9: ...that will be visible through the glass must be finished Refer to the chart for panel specifica tions You may also use your own handle hardware to match sur rounding cabinetry If you do not use the pre...

Страница 10: ...2 screws provided Exercise caution when drilling holes for mounting hardware This is especially critical with inset panels Before attaching the overlay panel to the door insert two screws one in the...

Страница 11: ...ocate screws drive the screws into the panel through the black tape on the door frame The screw holes inside the door are hidden under a cover flap on the door gasket It is necessary to lift the flap...

Страница 12: ...ng holes in the door frame The nature of the door panel with a narrow outer rim and no connecting center member requires the support provided by the glass door After the door panel installation is com...

Страница 13: ...ured in place with the anti tip bracket Is the unit level Are all leveling legs making contact with the floor Is the kickplate installed properly Is the water supply connected model UC 24CI Have you c...

Страница 14: ...stomer service at 800 222 7820 When calling for service you will need the model and serial number of your unit Both numbers are listed on the product rating plate located inside the cabinet in the upp...

Страница 15: ...ll rights reserved Wolf Wolf Design Wolf Gourmet W Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance Inc Sub Zero Sub Zero Design Dual Refriger...

Страница 16: ...SUB ZERO INC P O BOX 44848 MADISON WI 53744 SUBZERO COM 800 222 7820 7020381 REV A 10 2010...

Отзывы: