2-4

#7040158 - Revision B - June, 2015

Electronic Control Info.

INTEGRATED WINE (IW) SERIES

INTEGRATED WINE (IW) SERIES

(DOT DENOTES
PIN #1 LOCATION)

MAIN CONTROL BOARD

ST-1

ST-3

ST-4

ST-5

ST-7

ST-10

ST-6

ST-13

ST-11

ST-9

ST-8

ST-12

ST-2

Figure 2-2.  Control Board Layout

Figure 2-3.  Control Board Summary Table (IW-30R Summary Table Shown)

CONTROL BOARD LAYOUT AND SUMMARY TABLE

The electrical connection points on the control board are labeled alphanumerically.  These labels correspond with
the alphanumeric control board summary table, located on the wiring diagrams.  By referencing the summary table,
it is possible to identify which components are connected at which connection points on the control board.  Below is
a layout diagram of the control board, and a copy of a summary table.  (See Figures 2-2 and 2-3)

NOTE:  

All components on the control board are non-replaceable.  If a problem with the control board is identified,

the complete control board must be replaced.

IW-R CONTROL BOARD SUMMARY

CIRCUIT

DESCRIPTION

120 VOLTAGE

LOW VOLTAGE CIRCUITS

THERMISTOR CIRCUITS

LOW VOLTAGE CONT.

FUNCTION

COLOR

CIRCUIT

DESCRIPTION

FUNCTION

COLOR

ST1-1
ST1-2
ST1-3
ST1-4

ST2-1
ST2-2
ST2-3

ST3-1
ST3-2
ST3-3
ST3-4
ST3-5

ST4-1
ST4-2
ST4-3
ST4-4
ST4-5
ST4-6

ST5-1
ST5-2

POWER IN (L1)
WINE COMPRESSOR
REF COMPRESSOR
UNUSED

LINE POWER SUPPLY
NEUTRAL
EARTH GROUND

UNUSED
UNUSED
UNUSED
UNUSED
UNUSED

UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
CONDENSER FAN

HOME ALARM
HOME ALARM

POWER INTO BOARD
POWER WINE COMPRESSOR
POWER REF COMPRESSOR
UNUSED

POWER INTO BOARD
NEUTRAL INTO BOARD
GROUND

UNUSED
UNUSED
UNUSED
UNUSED
UNUSED

UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
POWERS CONDENSER FAN

HOME ALARM COMMON
HOME ALARM NORMALLY OPEN

BLACK

GRAY

PURPLE

--

ST10-1
ST10-2
ST10-3
ST10-4
ST10-5
ST10-6
ST10-7

UNUSED
UNUSED
UNUSED
UIM 12V POWER
UIM CAN BUS
UIM CAN BUS
UIM GROUND RETURN

UNUSED
UNUSED
UNUSED
UIM POWER
UIM CAN_H
UIM CAN_L
UIM RETURN

--
--
--

RED/WHITE

YELLOW/RED

YELLOW/WHITE

BROWN/WHITE

ST11-1
ST11-2
ST11-3
ST11-4
ST11-5
ST11-6
ST11-7
ST11-8

UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED

UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED

--
--
--
--
--
--
--
--

ST12-1
ST12-2
ST12-3
ST12-4

UNUSED
UNUSED
UNUSED
UNUSED

UNUSED
UNUSED
UNUSED
UNUSED

--
--
--
--

ST13-1
ST13-2
ST13-3
ST13-4
ST13-5
ST13-6
ST13-7
ST13-8
ST13-9
ST13-10

STEPPER VALVES WINE
STEPPER VALVES WINE
STEPPER VALVES WINE
STEPPER VALVES WINE
STEPPER VALVES WINE
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED

OUTPUT 1B
OUTPUT 1A
OUTPUT 2A
OUTPUT 2B
POWER
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED

BLUE

WHITE

WHITE/RED

BLUE/RED

RED

--
--
--
--
--

ST6-1
ST6-7
ST6-2
ST6-8
ST6-3
ST6-9
ST6-4
ST6-10
ST6-5
ST6-11
ST6-6
ST6-12

WINE UPPER CABINET
WINE UPPER CABINET
WINE UPPER EVAPORATOR
WINE UPPER EVAPORATOR
WINE LOWER CABINET
WINE LOWER CABINET
WINE LOWER EVAPORATOR
WINE LOWER EVAPORATOR
REF CABINET
REF CABINET
REF EVAPORATOR
REF EVAPORATOR

SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE
SENSES TEMPERATURE

BLUE/ORANGE

BROWN

BLUE/YELLOW

BROWN

BLUE

BROWN

BLUE/BLACK

BROWN

BLUE/PURPLE

BROWN

BLUE/GREEN

BROWN

BLACK
WHITE

GREEN/YELLOW

--
--
--
--
--

--
--
--
--
--

WHITE/RED

GRAY/WHITE

WHITE/RED

ST7-1
ST7-2
ST7-3
ST7-4
ST7-5
ST7-6
ST7-7
ST7-8
ST7-9
ST7-10
ST7-11
ST7-12

ST8-1
ST8-2
ST8-3
ST8-4
ST8-5
ST8-6

ST9-1
ST9-2
ST9-3
ST9-4
ST9-5
ST9-6
ST9-7
ST9-8
ST9-9

UNUSED
UNUSED
UNUSED
UNUSED
EVAP FAN 12 VDC POWER
WINE EVAP FAN
WINE EVAP FAN
EVAP FAN GROUND RETURN
WINE EVAP FAN
WINE EVAP FAN
REF EVAP FAN
REF EVAP FAN

DOOR LED
DOOR LED
DOOR LED
DOOR LED
DOOR LED
DOOR LED

DOOR SWITCH
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
DOOR SWITCH GROUND

UNUSED
UNUSED
UNUSED
UNUSED
EVAP FAN POWER
VAR. SPEED CONTROL OUT
TACH INPUT
EVAP FAN RETURN
VAR. SPEED CONTROL OUT
TACH INPUT
VAR. SPEED CONTROL OUT
TACH INPUT

DOOR LED POWER
DOOR LED PWM
DOOR LED GROUND
DOOR LED POWER
DOOR LED PWM
DOOR LED GROUND

DOOR SWITCH INPUT
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
GROUND

--
--
--
--

RED

YELLOW

BLUE

BLACK/RED

YELLOW/BROWN

BLUE/BROWN
YELLOW/PINK

BLUE/PINK

RED/GREEN

YELLOW/GREEN

BLACK/GREEN

RED/ORANGE

YELLOW/ORANGE

BLACK/ORANGE

YELLOW/BLACK

--
--
--
--
--
--
--

BLACK/YELLOW

Содержание IW-30R

Страница 1: ...Controls Operation 7 subzero com 800 222 7820 Integrated Wine Storage Service Manual...

Страница 2: ...Display A semi liquid substance sandwiched between glass in the control panel assembly The molecules of this semi liquid substance have no specific orientation However when electricity is applied to...

Страница 3: ...E RED M PURPLE GRAY WHITE BLACK GRAY PURPLE WHITE REF COMPRESSOR STARTING RELAY WINE COMPRESSOR STARTING RELAY DOT DENOTES PIN 1 LOCATION MAIN CONTROL OARD ST 1 4321 ST 2 321 ST 3 12345 ST 6 ST 4 1234...

Страница 4: ...T11 6 ST11 7 ST11 8 UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED ST12 1 ST12 2 ST12 3 ST12 4 UNUSED UNUSED UNUSED UNUSED UNUSED UNUSE...

Страница 5: ...onds and current internal temperature readings will appear on the UIM See Figure 2 5 power 70 70 Figure 2 6 Home Screen Touch Appropriate Temperature to Adjust Set Point Home Screen Wine Zones Only Do...

Страница 6: ...he display Below are the different option screens depending on the model See Figure 2 8 and Figure 2 9 Touch the icon option desired on or off see Option Screens Icon table below Figure 2 10 A dark ic...

Страница 7: ...e is displayed Touch drawer temperature See Figure 2 12 3 Temperature Set Point Adjust Screen is displayed Touch the or icon in multiple strokes to change the temperature See Figure 2 13 NOTE Refriger...

Страница 8: ...ntrol panel brightness and contrast Touch to adjust door drawer alarm volume and pitch Touch to adjust door drawer alarm duration Touch to enter Sabbath mode Touch to view troubleshooting and service...

Страница 9: ...on the UIM in the desired language Touch the language desired See Figure 2 18 NOTE Touching the Arrow key will step back one screen If the screen is not touched for ten 10 to fifteen 15 seconds the ho...

Страница 10: ...ettings icon the cog touch the brightness and contrast icon 1 2 dark sun icon on the settings screen to view or change the brightness and or contrast of the LCD of the UIM Touch the appropriate slide...

Страница 11: ...to fifteen 15 seconds the home screen will reappear 60S Door Alarm Time Figure 2 23 Door Alarm Time Screen sixty seconds chosen Star K Sabbath Mode Screen After touching the settings icon the cog touc...

Страница 12: ...re 2 26 Enter Password Screen Service Options Screen Code Requested After the password is entered the Service Options screen appears and the options can be scrolled in a loop The options to choose fro...

Страница 13: ...dash in multiple strokes until the appropri ate symbols appear See Figure 2 29 5 Showroom Mode screen is displayed Press Start to activate showroom mode See Figure 2 30 or press Stop to deactivate sho...

Страница 14: ...ches low offset temperature the fan is switched OFF but the compressor may stay energized if the other wine zone is calling for cooling Though compartment air temperature fluctuates from OFF and ON cy...

Страница 15: ...porator fan will be switched ON Only after the evaporator temperature reaches 38 44 F 3 7 C will the com pressor be energized NOTES If a compartment thermistor is faulty the compressor defaults to X m...

Страница 16: ...33 34 35 36 37 38 39 40 42 43 44 45 46 50 55 56 60 65 66 70 71 72 73 74 75 Failures Open Short Closed Unstable Miswire Normal Temps Miswire Overheat Bad Ohms Too Warm Too Cold Large Temp Diff Second D...

Страница 17: ...Timeout Partial Communications Bad Micro Communication Micro Initialization Display Failure Flow Too Slow No Flow Framing Errors Excessive Collisions Data Overrun FMEA Error Calibration or Low Signal...

Отзывы: