![Sub-Zero IW-30R Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/sub-zero/iw-30r/iw-30r_service-manual_1388558017.webp)
Page 17
2-17
#7040158 - Revision B - June, 2015
INTEGRATED WINE (IW) SERIES
INTEGRATED WINE (IW) SERIES
Electronic Control Info.
10
15
20
30
35
40
44
45
50
60
90
95
98
Device/System
Thermistor Faults
Relay Faults
Defrost Heater Faults
Ice/Water/Accessory Faults
Fan Faults
Runtime Faults
Glass Heater Faults
Lighting Faults
Flow Meter Faults
Load/Component Faults
Control Faults
Diagnostics
Power Faults
0
1
2
3
4
5
6
7
8
9
A
L
U
H
C
b
Zones
Misc
Zone 1
Zone 2
Zone 3
Defrost System
Control System
Compressors
Ambient
Icemaker
Dispenser
Air Filter
Lighting
Water System
High Voltage System
Condenser
Baffle
80
81
82
83
84
85
86
87
90
92
93
95
96
97
98
99
Failures
No Communication
Communications Timeout
Partial Communications
Bad Micro Communication
Micro Initialization
Display Failure
Flow Too Slow
No Flow
Framing Errors
Excessive Collisions
Data Overrun
FMEA Error
Calibration or Low Signal Error
Quantum SPI
Brownout
Other
Error Severity Explained
Low
1 = Error is logged and only readable through service menu, no indication to user, no chime
2 = Splash screen with wrench and error code for ten (10) seconds to user upon door opening, error
logged in service and user menu. No chime
Med
3 = Wrench and error code steady on screen to user upon door opening, error logged in service and user
menu, No chime
4 = Wrench and error code steady on screen to user upon door opening, error logged in service and user
menu, with chime when door open
Critical 5 = Wrench and error code steady on screen to user upon door opening, error logged in service and user
menu, with chime when door closed