![Sub-Zero IS15/S Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/sub-zero/is15-s/is15-s_use-and-care-information-manual_1388137021.webp)
21
W O L F
T R O U B L E S H O OT I N G
G U I D E
T R O U B L E S H O OT I N G
G U I D E
P R O B L E M
P R O B A B L E C A U S E
C O R R E C T I O N
Nothing works
Steamer module is not
Have electrician verify that
connected to proper electrical
proper voltage is being applied
circuit.
to steamer module.
Fuse is blown or circuit
Have electrician replace fuse or
breaker is tripped.
reset circuit breaker.
No electricity supplied to
Have electrician check house
steamer module.
power supply.
Steamer module is in
Unlock the control panel
Lock mode.
(see page 8).
”Lo” appears in
Steamer module was started
Follow instructions for Water
temperature display
with no water.
Level Safety Feature on page 11.
Steamer basin water level
Follow instructions for Water
is too low.
Level Safety Feature on page 11.
Dimensions in parentheses are in
millimeters unless otherwise specified.