Integrated Refrigeration
43
subzero.com/specs
Electrical Requirements
International models from the factory designed without a
transformer require a 220-240 V AC, 50/60 Hz electrical
supply, fused at the correct rating for the unit. If required
by local or national codes, the power cord can be easily
replaced using the power inlet device.
The electrical supply should be located within the shaded
area shown in the illustrations. Follow local codes and
ordinances when installing the receptacle. A separate
circuit, servicing only this appliance, is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
IMPORTANT NOTE:
It is critical that the electrical outlet be
located within the shaded area shown so it does not inter-
fere with installation of the anti-tip bracket. It must be
flush with the back wall and positioned with the grounding
prong to the right of the thinner blades.
Electrical Requirements
Power Supply
220-240 V AC, 50/60 Hz
Circuit Breaker
10 amp
Receptacle
3-prong grounding-type
330 mm
6
mm
114
mm
POSITION OUTLET WITH
GROUNDING PRONG
TO THE RIGHT
FLOOR
64 mm
FRONT VIEW
E
686 mm models.
914 mm models.
445 mm
114
mm
POSITION OUTLET WITH
GROUNDING PRONG
TO THE RIGHT
FRONT VIEW
FLOOR
64 mm
6
mm
E