MODEL ICBBI-48SD

The refrigerator door panel must include a cut-out to
accommodate the dispenser glasswell and bezel. The
thickness of the panel in this area can range from 6 mm to
a maximum of 29 mm. 

IMPORTANT NOTE:

Regardless of the thickness of the

panel for model ICBBI-48SD, you must plan for a flat
landing area for the decorative bezel surrounding the
glasswell area. The illustration to the right provides exact
bezel dimensions. Refer to the appropriate panel specifi-
cations page for exact cut-out location. This landing area
can be accomplished in a number of different ways. 

One option (flush) is to rout the panel so the bezel will be
flush with rails and stiles. You must rout a space to
accommodate the height and width of the bezel. The
width of the stile immediately to the left of the bezel must
be 44 mm. Do not cut the entire stile to this dimension.

The other option (proud) shows a boxed out landing area
for the bezel using stiles and rails to create this space. In
this application, the bezel will sit proud of the stiles and
rails. The total thickness of the panels at this level must
not exceed 29 mm.

Handle placement.

51 mm

25

mm

GLASSWELL

HANDLE

160 mm

2 mm

3 mm

RADIUS

16 mm

327
mm

Dispenser dimensions.

For overlay and flush inset models, mounting placement of
the refrigerator door handle must assure proper access to
the glasswell and adequate clearance under the handle.
The handle placement illustration shows the relation of the
refrigerator door handle to the glasswell bezel on stainless
steel models. 

Содержание ICBB-36R

Страница 1: ...INTERNATIONAL DESIGN GUIDE ...

Страница 2: ...Refrigeration 3 PRO 48 Refrigeration 34 Integrated Refrigeration 39 Wine Storage 51 Features and specifications are subject to change at any time without notice Visit subzero com specs for the most up to date information ...

Страница 3: ...mm 1219 mm 1067 mm 1067 mm 2134 mm 914 mm ICBBI 36F ICBBI 36U ICBBI 30U ICBBI 36S ICBBI 42S ICBBI 42SD ICBBI 48S ICBBI 48SD BUILT IN MODELS KEY FEATURES Three distinct design approaches overlay flush inset and stainless steel Handle options coordinate with handles of Wolf cooking products Dual refrigeration two compressors preserve food s goodness in two sealed compartments Energy efficient Advanc...

Страница 4: ... 227 ICBBI 42S 455 227 ICBBI 42SD 453 230 ICBBI 48S 533 270 ICBBI 48SD 531 274 Shipping Weight kg ALL REFRIGERATOR ALL FREEZER MODELS ICBBI 36R 191 ICBBI 36F 184 OVER AND UNDER MODELS ICBBI 30U 210 ICBBI 36U 234 SIDE BY SIDE MODELS ICBBI 36S 244 ICBBI 42S 264 ICBBI 42SD 276 ICBBI 48S 286 ICBBI 48SD 298 Shipping weights and overall dimensions are based on stainless steel models For flush inset appl...

Страница 5: ...02 mm 1289 mm 584 mm 606 mm 600 mm 796 mm 368 mm 606 mm 60 mm HEIGHT DIMENSIONS 13 mm MODEL ICBBI 30U 914 mm 2134 mm 610 mm 102 mm 1289 mm 584 mm 606 mm 600 mm 946 mm 432 mm 606 mm 60 mm HEIGHT DIMENSIONS 13 mm MODEL ICBBI 36U Over and Under Models OVERALL DIMENSIONS ...

Страница 6: ...to door clearance dimensions 1067 mm 2134 mm 610 mm 102 mm 1873 mm 606 mm 606 mm 668 mm 318 mm 222 mm 60 mm HEIGHT DIMENSIONS 13 mm MODELS ICBBI 42S AND ICBBI 42SD 914 mm 2134 mm 610 mm 102 mm 1873 mm 606 mm 565 mm 216 mm 260 mm 606 mm 60 mm HEIGHT DIMENSIONS 13 mm MODEL ICBBI 36S Side by Side Models OVERALL DIMENSIONS ...

Страница 7: ...n Refrigeration 7 subzero com specs 1219 mm 2134 mm 610 mm 102 mm 1873 mm 606 mm 606 mm 762 mm 356 mm 248 mm 60 mm HEIGHT DIMENSIONS 13 mm Side by Side Models OVERALL DIMENSIONS MODELS ICBBI 48S AND ICBBI 48SD ...

Страница 8: ...4 mm ICBBI 48S and ICBBI 48SD 1206 mm IMPORTANT NOTE If two units are installed side by side refer to pages 21 22 for dual standard installations Stainless steel models are ready to install out of the box 610 mm OPENING DEPTH FRONT VIEW SIDE VIEW TOP VIEW A OPENING WIDTH 610 mm OPENING DEPTH 2127 mm OPENING HEIGHT Built In Models STANDARD INSTALLATION ...

Страница 9: ...he power inlet device For all built in models the electrical supply should be located within the shaded area shown in the illustration Follow local codes and ordinances when installing the receptacle A separate circuit servicing only this appliance is required A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation PLUMBING REQUIREMENTS For built in model...

Страница 10: ...els and handles to give the unit a more custom look The overlay panel design option is available for all built in overlay models For exact door panel dimen sions refer to overlay panel specifications on the following pages IMPORTANT NOTE Overlay models can be used in an overlay or a flush inset application Be aware that the application specified will affect panel sizes rough opening dimensions and...

Страница 11: ...st be ordered to accept a 2108 mm or 2235 mm custom panel Width dimensions do not vary Model ICBBI 30U REFRIGERATOR W H Overlay Panel 762 mm 1273 mm Spacer Panel 740 mm 1253 mm Backer Panel 756 mm 1268 mm FREEZER W H Overlay Panel 762 mm 483 mm Spacer Panel 740 mm 459 mm Backer Panel 756 mm 475 mm GRILLE W H Overlay Panel 762 mm 235 mm Spacer Panel 740 mm 211 mm Backer Panel 756 mm 227 mm Model IC...

Страница 12: ...R W H Overlay Panel 483 mm 1772 mm Spacer Panel 460 mm 1751 mm Backer Panel 476 mm 1767 mm GRILLE W H Overlay Panel 1219 mm 235 mm Spacer Panel 1197 mm 211 mm Backer Panel 1213 mm 227 mm ICBBI 48SD W H Dispenser Cut Out 149 mm 316 mm A B Cut Out Location 51 mm 732 mm Model ICBBI 42S REFRIGERATOR W H Overlay Panel 637 mm 1772 mm Spacer Panel 614 mm 1751 mm Backer Panel 630 mm 1767 mm FREEZER W H Ov...

Страница 13: ...eter of the unit and grille to allow for proper door swing and airflow IMPORTANT NOTE The flush inset application is not a separate model This is an overlay unit in a flush installa tion The same model is used in an overlay or flush inset application Rough opening dimensions for the flush inset application assume the use of a 19 mm decorative panel The illustra tions at right show the difference b...

Страница 14: ...EL DETAIL A DETAIL B FRONT VIEW A WIDTH TO CLEAT B FLUSH INSET WIDTH 32 mm 32 mm SIDE VIEW 2134 mm FLUSH INSET HEIGHT 6 mm 610 mm DEPTH TO CLEAT 665 mm FLUSH INSET DEPTH 56 mm 2127 mm HEIGHT TO CLEAT 610 mm DEPTH TO CLEAT 665 mm FLUSH INSET DEPTH TOP VIEW 56 mm 32 mm CLEAT CLEAT Detail A Detail B 32 mm 610 mm OPENING DEPTH TO CLEAT CLEAT TOP VIEW 665 mm FLUSH INSET DEPTH 56 mm 76 mm typical 610 mm...

Страница 15: ...cement to ensure a proper fit Flush Inset Panel Requirements MAX WEIGHT PER PANEL All Flush Inset Models 23 kg Grille Panel 6 kg MIN PANEL THICKNESS All Flush Inset Panels 16 mm 6 mm 3 mm FLUSH INSET PANEL SPACER PANEL BACKER PANEL 19 mm typical Three panel assembly The illustration below provides a rear view of the three panel assembly with critical dimensions standard for all built in models IMP...

Страница 16: ... Grille Sides A Grille Top C Grille Bottom Door Top D Door Bottom Drawer Top E Drawer Bottom F SIDE BY SIDE Doors hinge Grille Sides A Doors handle Sides B Grille Top C Grille Bottom Door Top D Door Bottom F Flush Inset Panels PANEL OFFSETS Illustrations A F provide panel offsets and reveals for all built in models in a flush inset application Refer to the chart below for reference to the illustra...

Страница 17: ... W H Flush Inset Panel 787 mm 1273 mm Spacer Panel 740 mm 1253 mm Backer Panel 756 mm 1268 mm FREEZER W H Flush Inset Panel 787 mm 483 mm Spacer Panel 740 mm 459 mm Backer Panel 756 mm 475 mm GRILLE W H Flush Inset Panel 787 mm 235 mm Spacer Panel 740 mm 211 mm Backer Panel 756 mm 227 mm Model ICBBI 36U REFRIGERATOR W H Flush Inset Panel 940 mm 1273 mm Spacer Panel 892 mm 1253 mm Backer Panel 908 ...

Страница 18: ...l 1197 mm 211 mm Backer Panel 1213 mm 227 mm DISPENSER ICBBI 48SD W H Cut Out 149 mm 316 mm A B Cut Out Location 51 mm 732 mm Model ICBBI 42S REFRIGERATOR W H Flush Inset Panel 649 mm 1772 mm Spacer Panel 614 mm 1751 mm Backer Panel 630 mm 1767 mm FREEZER W H Flush Inset Panel 437 mm 1772 mm Spacer Panel 402 mm 1751 mm Backer Panel 418 mm 1767 mm GRILLE W H Flush Inset Panel 1092 mm 235 mm Spacer ...

Страница 19: ... will be flush with rails and stiles You must rout a space to accommodate the height and width of the bezel The width of the stile immediately to the left of the bezel must be 44 mm Do not cut the entire stile to this dimension The other option proud shows a boxed out landing area for the bezel using stiles and rails to create this space In this application the bezel will sit proud of the stiles a...

Страница 20: ... mm thick Refer to the illustrations below for side panel dimensions Routing will be necessary so that the side panel fits flush against the side of the unit 2134 mm 610 mm ROUT TO 5 mm OVER AND UNDER MODELS OPTIONAL TOE KICK CUT OUT 102 mm 521 mm 146 mm 48 mm 25 mm 108 mm ROUT TO 3 mm FRONT OF SIDE PANEL 67 mm Side panel dimensions IMPORTANT NOTE If you have a model ICBBI 30U or ICBBI 36U extra r...

Страница 21: ...tion between the units Be sure to add the filler strip width to your rough opening width Refer to the full scale template on page 32 Dual installations without a filler strip can only be accom plished using two units with opposite hinges as shown in illustration A below The dual installations shown in illus trations B and C require a filler strip IMPORTANT NOTE For the application shown in illustr...

Страница 22: ...ual installation kit will be required for this installation Stainless steel models are ready to install out of the box FRONT VIEW SIDE VIEW TOP VIEW 2127 mm OPENING HEIGHT A OPENING WIDTH 610 mm OPENING DEPTH 610 mm OPENING DEPTH TWO UNITS WITH 19 mm PANEL Dual Installation STANDARD INSTALLATION Built In Refrigeration 22 ...

Страница 23: ...tion A is the only application that will accommodate the dual wide grille IMPORTANT NOTE The application shown in illustration A can only be achieved by installing dual flush inset panels Failure to install dual flush inset panels will cause the handle side of the panels to collide when closing In this application a dual installation accessory kit is also required Dual flush inset panels and dual ...

Страница 24: ...56 mm A WIDTH TO CLEAT B FLUSH INSET WIDTH 32 mm 32 mm SIDE VIEW 2134 mm FLUSH INSET HEIGHT 6 mm 610 mm DEPTH TO CLEAT 665 mm FLUSH INSET DEPTH 56 mm 2127 mm HEIGHT TO CLEAT CLEAT TWO UNITS WITH 19 mm PANEL DETAIL A DETAIL B 32 mm CLEAT Detail A Detail B 32 mm 610 mm OPENING DEPTH TO CLEAT CLEAT TOP VIEW 665 mm FLUSH INSET DEPTH 56 mm 76 mm typical 610 mm OPENING DEPTH TO CLEAT 32 mm 56 mm CLEAT S...

Страница 25: ...h inset application Refer to the chart below for reference to the illustrations relating to your specific model All reveals are 13 mm unless other wise specified For additional information on model specific panel reveals visit the specification library section of our website subzerotrade com 16 mm 8 mm 13 mm FLUSH INSET PANEL SPACER BACKER DOOR DRAWER GRILLE TOP VIEW CABINETRY Illus A Illus B DUAL...

Страница 26: ...mm FREEZER W H Flush Inset Panel 775 mm 483 mm Spacer Panel 740 mm 459 mm Backer Panel 756 mm 475 mm GRILLE W H Flush Inset Panel 775 mm 235 mm Spacer Panel 740 mm 211 mm Backer Panel 756 mm 227 mm ICBBI 36U REFRIGERATOR W H Flush Inset Panel 927 mm 1273 mm Spacer Panel 892 mm 1253 mm Backer Panel 908 mm 1268 mm FREEZER W H Flush Inset Panel 927 mm 483 mm Spacer Panel 892 mm 459 mm Backer Panel 90...

Страница 27: ...h unit The kit includes a 6 mm filler strip which fills the reveal between the units and grilles heater and mounting hardware This dual installation kit is not required if a custom filler strip is used The filler strip should be a minimum of 51 mm wide Refer to the full scale template on page 32 for more information Dual Wide Grille Overlay TWO 762 mm MODELS W H Overlay Panel 1530 mm 235 mm Spacer...

Страница 28: ...es Dual installation kits with and without dual wide grille Retrofit kits for use with 600 series panels STANDARD HANDLES Refer to the chart below for standard handle lengths and the stud spacing of tubular and pro handles used on built in models Built In Refrigeration 28 Standard Handles Length Stud Spacing FULL HEIGHT DOOR Tubular Handle 1622 mm 1114 mm Pro Handle 1146 mm 1114 mm ICBBI 30U AND I...

Страница 29: ... 19 mm PANEL 51 mm 3 mm SPACER PANEL Overlay Panel Thickness FULL SCALE TEMPLATE Overlay and flush inset panels must be a minimum of 16 mm thick to support mounting the handle Panel thickness does not include backer and spacer panel Mount handle close to the opening edge of the door PANEL THICKNESS OVERLAY AND FLUSH INSET APPLICATIONS ...

Страница 30: ...LL WIDTH OF UNIT 32 mm 38 mm 44 mm 0 mm 25 mm 51 mm 57 mm 63 mm 70 mm 76 mm 83 mm 89 mm 6 mm 13 mm 19 mm 19 mm THICK OVERLAY PANEL TYPICAL 6 mm BACKER PANEL 25 mm THICK PANEL Overlay Application FULL SCALE TEMPLATE DOOR OPENING 90 TOP VIEW 25 mm 0 mm SCALE ...

Страница 31: ...56 mm 610 mm TO BACK WALL 19 mm THICK FLUSH INSET PANEL TYPICAL 6 mm BACKER PANEL 25 mm THICK PANEL Flush Inset Application FULL SCALE TEMPLATE For panels thicker than 19 mm a 90 door stop may be required to prevent interference with adjacent cabinets DOOR OPENING 110 TOP VIEW 25 mm 0 mm SCALE ...

Страница 32: ...ED DOOR AND HANDLE DOOR OPEN 110 DOOR CLOSED Dual Installation Standard FULL SCALE TEMPLATE Typical overlay or stainless steel dual installation with filler strip at maximum 110 door opening Depending on panel thickness a 90 door stop may be required STANDARD TOP VIEW 25 mm 0 mm SCALE ...

Страница 33: ...SH INSET PANEL AND TUBULAR HANDLE DOOR CLOSED DOOR OPEN 110 Dual Installation Flush Inset FULL SCALE TEMPLATE Typical flush inset dual installation with filler strip at maximum 110 door opening Depending on panel thickness a 90 door stop may be required FLUSH INSET TOP VIEW 25 mm 0 mm SCALE ...

Страница 34: ... either built in or freestanding 1219 mm 2134 mm 1219 mm 2134 mm ICB648PRO ICB648PROG PRO 48 MODELS KEY FEATURES Can be used freestanding or installed as a standard or flush built in application Handles coordinate with handles of Wolf ranges Stainless steel interior as well as exterior Dual refrigeration system enhanced with triple evapora tors allow independent control of storage conditions in re...

Страница 35: ...mm 775 mm 606 mm 1070 mm 368 mm 781 mm 533 mm 60 mm HEIGHT DIMENSIONS 13 mm MODELS ICB648PRO AND ICB648PROG PRO 48 Models OVERALL DIMENSIONS SPECIFICATIONS Capacity Weight INTERIOR CAPACITY R L F L ICB648PRO and ICB648PROG 520 332 SHIPPING WEIGHT KG ICB648PRO 390 ICB648PROG 397 ...

Страница 36: ...e of the unit will extend 51 mm beyond cabinetry In flush built in installations the front of the face frame will be flush with surrounding cabinetry Opening Dimensions Standard Flush Opening Width 1206 mm 1219 mm Opening Height 2127 mm 2137 mm Opening Depth 610 mm 660 mm PRO 48 Models STANDARD AND FLUSH BUILT IN INSTALLATIONS PRO 48 Refrigeration 36 ...

Страница 37: ...ircuit interrupter GFCI is not recommended and may cause interruption of opera tion Electrical Requirements Power Supply 220 240 V AC 50 60 Hz Circuit Breaker 10 amp Receptacle 3 prong grounding type PLUMBING REQUIREMENTS PRO 48 models come with an automatic ice maker The water supply line should be located within the shaded area shown in the illustration below The water supply line should be conn...

Страница 38: ... visit the find a showroom section of our website subzero com Freestanding kit which contains two stainless steel side panels and top lid Stainless steel side panel Refrigerator drawer dividers for compartmentalized storage Stainless steel slide out refrigerator bin Dozen egg container 90 door stop PRO 48 Refrigeration 38 ...

Страница 39: ...utiful in the master suite bar or theatre room as in the kitchen 914 mm 2032 mm 914 mm 2032 mm ICB736TR ICB736TCI 686 mm 2032 mm 686 mm 2032 mm ICB700TR ICB700TCI 876 mm 686 mm ICB700BR KEY FEATURES Custom cabinet fronts and hardware allow for infinite design options Point of use refrigeration that can be placed anywhere in the home Dual refrigeration two compressors preserve food s goodness in se...

Страница 40: ...m 178 mm HEIGHT DIMENSIONS 13 mm 914 mm TALL MODELS Integrated Refrigeration 40 Overall Dimensions 686 mm TALL MODELS MODELS ICB700TR AND ICB700TCI 686 mm 356 mm 21 mm 876 mm 610 mm 518 mm 260 mm 337 mm DIMENSIONS WILL VARY WITH PANEL THICKNESS 13 mm 10 mm 495 mm 648 mm 117 mm 2032 mm TO TOP OF OPENNG 610 mm 1995 mm 248 mm 102 mm HEIGHT DIMENSIONS 13 mm Overall dimensions do not include panels or ...

Страница 41: ...CB736TCI 378 200 686 mm DRAWER MODEL ICB700BR 149 Capacity and Weight Shipping Weight kg ICB700TR and ICB700TCI 163 ICB736TR and ICB736TCI 218 ICB700BR 86 MODEL ICB700BR 686 mm 876 mm 610 mm 518 mm DIMENSIONS WILL VARY WITH PANEL THICKNESS 13 mm 10 mm 495 mm 657 mm 610 mm 248 mm 102 mm 260 mm 337 mm HEIGHT DIMENSIONS 13 mm Overall Dimensions DRAWER MODELS ...

Страница 42: ...rd to achieve a flush fit This will require a minimum rough opening depth of 635 mm 635 mm OPENING DEPTH A OPENING WIDTH 635 mm OPENING DEPTH B OPENING HEIGHT TOP VIEW FRONT VIEW SIDE VIEW Opening Dimensions INTEGRATED MODELS Opening Dimensions A B ICB700TR ICB700TCI 686 mm 2032 mm ICB736TR ICB736TCI 914 mm 2032 mm ICB700BR 686 mm 876 mm Integrated Refrigeration 42 ...

Страница 43: ...s appliance is required A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation IMPORTANT NOTE It is critical that the electrical outlet be located within the shaded area shown so it does not inter fere with installation of the anti tip bracket It must be flush with the back wall and positioned with the grounding prong to the right of the thinner blades E...

Страница 44: ...ea shown so it does not inter fere with installation of the anti tip bracket An in line filter is required when water conditions have a high sediment content The ice maker operates on constant water pressure between 1 4 bar and 6 9 bar IMPORTANT NOTE In some cases a reverse osmosis water filter system may not be able to maintain the minimum pressure consistently Plumbing Requirements Water Supply ...

Страница 45: ... ARE 3 mm Panel dimensions are based on a 3 mm reveal A reveal of up to 6 mm is possible with adjustments to panel dimensions 686 mm MODELS TALL AND DRAWER MODELS 914 mm MODELS TALL MODELS Typical Panel Dimensions 686 mm MODELS W H Door 679 mm 1153 mm Top Drawer 679 mm 345 mm Bottom Drawer 679 mm 424 mm 914 mm MODELS W H Door 908 mm 1153 mm Top Drawer 908 mm 345 mm Bottom Drawer 908 mm 424 mm Cabi...

Страница 46: ...END BEYOND THE FRONT OF THE MOLDING DECORATIVE VALANCE REMOVABLE MOLDING TYPICAL HEIGHT OF DOOR PANEL MINIMUM HEIGHT OVERALL HEIGHT 3 mm 3 mm DOOR PANEL 635 mm TO WALL HEIGHT OF PANEL INTEGRATED UNIT SIDE VIEW 67 mm TO 102 mm BASE MOLDING MUST BE REMOVABLE KICKPLATE GRILLE CAN BE ADJUSTED FORWARD KICKPLATE GRILLE 102 mm TO 229 mm FROM FLOOR TOE KICK CLEARANCE The toe kick clearance can vary with t...

Страница 47: ...ut reveals can be increased to up to 6 mm When 19 mm or thicker panels are used with a reveal of less than 6 mm door panels may cause damage to the unit when the door is opened to the maximum 105 Use the built in 90 door stop As reveals between cabinetry and the unit decrease the potential exists for severe finger pinching while the door is closing IMPORTANT NOTE The inside edges of the rough open...

Страница 48: ...slightly from single installations Refer to the chart below for typical panel dimensions The dimensions are based on a 3 mm reveal A reveal of up to 6 mm is possible with adjustments to panel dimensions Typical Panel Dimensions 686 mm MODELS W H Door 681 mm 1153 mm Top Drawer 681 mm 345 mm Bottom Drawer 681 mm 424 mm 914 mm MODELS W H Door 910 mm 1153 mm Top Drawer 910 mm 345 mm Bottom Drawer 910 ...

Страница 49: ...er drawer with shelf assembly deli drawer with shelf and crisper cover with lid for certain models Dual installation kit Harness kit for Star K compliance STANDARD HANDLES Refer to the chart below for standard handle lengths and the stud spacing of tubular and pro handles used on integrated models Standard Handles Length Stud Spacing DOOR Tubular Handle 1046 mm 845 mm Pro Handle 1006 mm 973 mm 686...

Страница 50: ... 105 OPENING 19 mm INTEGRATED DOOR MAXIMUM 105 OPENING LINE OF INTERFERENCE Maximum Door Opening FULL SCALE TEMPLATE If the panel is thicker than 19 mm use the built in 90 door stop to prevent damage to the panel and face frame at the maximum door opening 105 OPENING TOP VIEW 1 4 SCALE DOOR CLOSED TOP VIEW FULL SCALE Integrated Refrigeration 50 25 mm 0 mm SCALE ...

Страница 51: ... mm ICB427G ICB427RG ICBWS 30 616 mm 868 mm 864 mm 606 mm ICB424G ICB424FSG KEY FEATURES Integrated overlay flush inset and stainless steel design options Full view glass door standard on all models Freestanding model ICB424FSG does not require panels or surrounding cabinetry Discreet interior lighting with illuminated display shelf WINE STORAGE MODELS Two independent storage zones maintain temper...

Страница 52: ...Wine Storage 52 Overall Dimensions UNDERCOUNTER WINE STORAGE 606 mm 610 mm 864 mm 645 mm 102 mm 60 mm MODEL ICB424G Overall dimensions are based on stainless steel panels and handles ...

Страница 53: ... 610 mm 1995 mm 227 mm 102 mm HEIGHT DIMENSIONS 13 mm 610 mm DIMENSIONS WILL VARY WITH PANEL THICKNESS 648 mm 117 mm 686 mm 356 mm 21 mm 876 mm 518 mm 260 mm 337 mm 13 mm 10 mm 2032 mm OPENING HEIGHT 610 mm 1995 mm 248 mm 102 mm HEIGHT DIMENSIONS 13 mm 610 mm DIMENSIONS WILL VARY WITH PANEL THICKNESS 495 mm 648 mm 117 mm Overall dimensions do not include panels or handles ...

Страница 54: ...SG 100 ICB427G 179 ICB427RG 186 ICBWS 30 202 Capacity and Weight 762 mm 2134 mm 610 mm 102 mm 1873 mm 606 mm 796 mm 432 mm 606 mm 60 mm HEIGHT DIMENSIONS 13 mm MODEL ICBWS 30 Overall dimensions are based on the stainless steel model For flush inset applications add 13 mm to door clearance dimensions Overall Dimensions FULL SIZE WINE STORAGE ...

Страница 55: ...e depth of each integrated model is 610 mm from the front of the unit to its back Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit This will require a minimum rough opening depth of 635 mm 635 mm OPENING DEPTH 686 mm OPENING WIDTH 635 mm OPENING DEPTH 2032 mm OPENING HEIGHT TOP VIEW FRONT VIEW SIDE VIEW MODELS ICB427G AND ICB427RG MODEL ICB424G FULL SIZE ...

Страница 56: ... out For corner installations you need to allow for a minimum 76 mm filler so the door can open to 90 If you are using larger handle hardware you will also need to take that into account Refer to door clearance specifications For a maximum 90 door opening use the door stop built into the hinge system of model ICB427G A 90 door stop is shipped with model ICBWS 30 If you will be connecting the unit ...

Страница 57: ...equire a 220 240 V AC 50 60 Hz electrical supply fused at the correct rating for the unit If required by local or national codes the power cord can be easily replaced using the power inlet device The electrical supply should be located within the shaded area shown in the illustration for your specific model Follow local codes and ordinances when installing the receptacle A separate circuit servici...

Страница 58: ...e for the glass door If you order a stainless steel unit models ICB424G ICB424FSG and ICBWS 30 will be shipped with their panels and hardware installed For models ICB427G and ICB427RG optional stainless steel panels or custom panels will need to be installed The glass door is designed to be exposed to room air cir culation Decorative overlays on the glass should be kept to a minimum Also rails and...

Страница 59: ...D ICB427RG The integrated full panels or frame panels for glass doors for these models will follow some of the identical planning processes used with the integrated line The installation of the door panels is completely different however Rather than using the mounting hardware we used with the inte grated line door panels for both models ICB427G and ICB427RG will be applied with screws applied thr...

Страница 60: ... it must fit over the door frame IMPORTANT NOTE Do not cover the glass door with a solid panel The window cut out edges of the overlay spacer and backer panels will need to be finished as they will be exposed OVERLAY PANEL SPECIFICATIONS Do not exceed overlay panel dimensions as this could cause damage to panels and the Sub Zero unit Wine Storage 60 3 mm OVERLAY PANEL SPACER PANEL BACKER PANEL TRI...

Страница 61: ...rlay spacer and backer panels will also need to be finished IMPORTANT NOTE For flush inset panels thicker than 19 mm a 90 door stop may be required to prevent inter ference with adjacent cabinets 14 mm FLUSH INSET PANEL SPACER PANEL BACKER PANEL TRIM 8 mm min Panel assembly cross section Panel assembly rear view 6 mm 3 mm FLUSH INSET PANEL SPACER PANEL BACKER PANEL 19 mm typical Grille panel dimen...

Страница 62: ... instructions For ques tions relative to the installation contact your Sub Zero dealer To obtain local dealer information visit the find a showroom section of our website subzero com DUAL STANDARD INSTALLATIONS Two overlay or stainless steel units may be placed side by side in a dual installation Some dual standard installations will require a dual installation kit available through your Sub Zero ...

Страница 63: ...stall dual flush inset panels will cause the handle side of the panels to collide when closing In this application a dual installation accessory kit is also required Dual flush inset panels and dual installation kits are avail able through your Sub Zero dealer Refer to the illustration and chart for dual flush inset panel specifications Grille panel dimensions listed are for a standard 2134 mm ove...

Страница 64: ...el offsets and reveals for model ICBWS 30 in a flush inset application Refer to the chart below for reference to the illustrations All reveals are 13 mm unless otherwise specified For additional information on panel reveals visit the speci fication library section of our website subzerotrade com 16 mm 8 mm 13 mm FLUSH INSET PANEL SPACER BACKER DOOR DRAWER GRILLE TOP VIEW CABINETRY Illus A Illus B ...

Страница 65: ...of the model ICBWS 30 you need to be aware of the space con figuration to achieve a pleasing fit Depending on the exact panel you are using the height of the panel may vary IMPORTANT NOTE The use of side panels may change the width of your rough opening When installing a model ICBWS 30 with a custom side panel an accessory kit 7003407 is required Stainless steel side panels are also available thro...

Страница 66: ...w for standard handle lengths and the stud spacing of tubular and pro handles used on wine storage models A 57 mm RAIL STILE GLASS A C L CABINET DOOR PROFILE Door Frame Profile FULL SCALE TEMPLATE The full scale template below shows an example of the door frame profile for wine storage models and the rela tionship to the overlay panel rails and stiles DOOR FRAME PROFILE MODEL ICB424G SHOWN Dimensi...

Страница 67: ...below To remove the cherry strips take the shelves out and remove the screws Reverse the procedure to affix the new wood facing IMPORTANT NOTE If you choose to stain or seal the wood facing be aware that some of these substances are hazardous and will damage stored wine Dimension A ICB424G and ICB424FSG 495 mm ICB427G and ICB427RG 532 mm ICBWS 30 624 mm A WIDTH MAXIMUM THICKNESS FRONT VIEW SIDE VI...

Страница 68: ...24G should extend a minimum of 6 mm beyond the front surface of adjoining cabinetry to allow for the maximum 145 door opening The unit can be installed flush with adjacent cabinetry however there is potential for interference with the panel if the door is opened past 90 DOOR OPENING 145 TOP VIEW Wine Storage 68 25 mm 0 mm SCALE ...

Страница 69: ...SUB ZERO INC PO BOX 44848 MADISON WI 53744 USA SUBZERO COM ISZDG 6 2010 ...

Отзывы: