Electrical
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Power Supply
220-240 V AC, 50/60 Hz
Circuit Breaker
10 amp
Receptacle
grounding-type (earthed)
ELECTRICAL SUPPLY LOCATION
WIDTH
A
457 mm Model
152 mm
610 mm Model
241 mm
762 mm Model
318 mm
914 mm Model
394 mm
A
6 mm
108
mm
114 mm
FRONT VIEW
FLOOR
LEFT SIDE
OF OPENING
E
Electrical supply location.
Plumbing
The water supply line should be located within the shaded
area shown in the illustrations below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip bracket.
A reverse osmosis system can be used provided there
is constant water pressure of 2.4–8.3 bar supplied to the
unit at all times. A copper line is not recommended for this
application.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply Line
1
/
4
" OD copper, braided
stainless steel or PEX tubing
Water Pressure
2.4–8.3 bar
Excess Water Line for Connection
.9 m
WATER SUPPLY LOCATION
WIDTH
A
457 mm Model
76 mm
610 mm Model
140 mm
762 mm Model
152 mm
914 mm Model
229 mm
76 mm
FRONT VIEW
FLOOR
TOP VIEW
BACK WALL
13 mm
152
mm
A
WATER
LINE
A
152
mm
RIGHT SIDE
OF OPENING
RIGHT
SIDE OF
OPENING
76 mm
FRONT VIEW
FLOOR
TOP VIEW
BACK WALL
13 mm
152
mm
A
WATER
LINE
A
152
mm
RIGHT SIDE
OF OPENING
RIGHT
SIDE OF
OPENING
Water supply location (rear).
Water supply location (bottom).