Integrated
Integrated
(700-
(700-
3
3
T
T
ALL)
ALL)
Series
Series
Installation Information
2-3
#3758412 - Revision B - December, 2006
Figure 2-4. Adjusting Rear Levelers
Figure 2-5. 90° Door Stop Cam
Screwdriver
The rear levelers are adjusted from the front of the
base by turning the Phillips head adjusting screw. The
long adjusting screw reaches all the way to the rear lev-
eler assembly. Turn the screw clockwise to raise the
rear or counterclockwise to lower it (See Figure 2-4).
NOTE:
The rear leveling legs will only move 1/16” for
every 18 revolutions of the Phillips head screw. Do not
over torque. Use the lowest torque setting on any
power screwdriver. Do not turn rear leveling legs by
hand, doing so will damage the assembly.
Door and Drawer Adjustment
The doors and drawers on 700-2 Series units are non-
adjustable. Instead, the door and/or drawer panels
must be adjusted if there is an alignment problem.
Refer to the Installation Manual and/or installation video
for panel installation and adjustment.
NOTE:
The unit must be level before attempting to
adjust the door and drawer panels.
NOTE:
If the door has problems closing, see Tall Unit
Door Hinge Operation Test Procedures and Corrections
at the end of the Troubleshooting Guide.
Door Stop Adjustment
700-2 Series tall units have a 90° door stop cam built
into the hinge system. The 90° door stop cam is locat-
ed in the center portion of each hinge. To adjust it, use
a standard straight-blade screwdriver to rotate the cam
until it reaches the stop point (See Figure 2-5).
NOTE:
You must make this adjustment at both bottom
and top hinge.
90° Stop Cam