TAPAS REFRIGERATOR
Manual for installation, use, and maintenance
VTP 139 SL VTP 175 SL
Страница 1: ...TAPAS REFRIGERATOR Manual for installation use and maintenance VTP 139 SL VTP 175 SL...
Страница 2: ...IONS 4 3 INSTALLATION 5 3 1 UNCRATING 5 3 2 LOCATION 5 3 3 DATA PLATE 6 3 4 LEVELING 6 3 5 ELECTRICAL CONNECTIONS 6 4 OPERATION 7 4 1 ELECTRONIC CONTROL 7 4 2 OTHER FUNCTIONS 10 5 MAINTENANCE 11 5 1 C...
Страница 3: ...al until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines are sec...
Страница 4: ...e outlet of the evaporator at 32 C 90 F Model Trays Amps HP Voltage Plug Type BTU Refrigerant charge oz Refrigerant VTP 139 SL 6 2 3 1 6 120 5 15P 850 6 7 134 A VTP 175 SL 9 2 3 1 6 120 5 15P 850 6 7...
Страница 5: ...higher than 60 the door frames may sweat water This is not a malfunctioning of the unit WARNING The following actions will void your warranty Modification of power cord Connecting the unit to any exte...
Страница 6: ...g Machine must be leveled front to back and side to side with a level tool Castors kit will include shims for leveling Insert the shim between the castor and the frame rail See installation of castors...
Страница 7: ...ld under any circumstance leave food overnight this will make the evaporator to become frozen and compressor damage may occur Damages caused by leaving the unit ON overnight with product will not be c...
Страница 8: ...roller The unit comes with a factory default set point 8 F Freezers 32 F Refrigerators These set values will make the unit perform at its maximum capacity Therefore it is not recommended to change the...
Страница 9: ...tton for five 5 seconds until PS is shown in the display Release the button and press the SET button one time Now you will see the number zero 0 With the button UP arrow set a value of 22 and then pre...
Страница 10: ...o start Note If the equipment doesn t reach the temperature first verify that the defrost cycle is not ON The unit will go into defrost every six hours for an average of 20 minutes The defrost cycle i...
Страница 11: ...deteriorate the stainless steel finish Be sure to clean ALL food products from any stainless steel surface Failure to do so will result in spots and rust on the surface affected 5 1 CLEANING THE CONDE...
Страница 12: ...s this can cause them to become brittle and prevent proper sealing Also never use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets c...
Страница 13: ...lear the drain pan as necessary to avoid puddles of water underneath the unit Do not store open containers with liquids inside the unit This will increase the amount condensation inside and outside of...
Страница 14: ...air flow product must not be placed higher than the maximum level mark located on the internal wall of the unit g If FREEZER check that the temperature is not Celsius C h Check that the gasket is in g...
Страница 15: ...TAPAS CASES SERVICE MANUAL Rev JUN 2015 Page15 www Fagorcommercial com 7 WIRING DIAGRAMS AUTR 48 60 72 APTS 48 60 72 APTM 48 60 72...
Страница 16: ...e replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warranty In...
Страница 17: ...unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have the right...
Страница 18: ...iveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted and rep...
Страница 19: ...TAPAS CASES SERVICE MANUAL Rev JUN 2015 Page19 www Fagorcommercial com Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 463 2467 www Fagorcommercial com...