background image

10

A N T I - T I P

B L O C K I N G   B R A C K E T

I N S T A L L C O N C R E T E   W E D G E   A N C H O R S

1)

Drill a 

3

/

8

" (10) diameter hole any depth

exceeding the minimum embedment. Clean
the hole or continue drilling additional
depth to accommodate drill fines. Use a
carbide drill bit manufactured within ANSI
B94.12-77.

2)

Assemble the washer and nut flush with the
end of anchor to protect threads. Drive the
anchor through the material to be fastened
until the washer is flush with the surface
material.

3)

Expand the anchor by tightening the nut
3–5 turns past hand-tight position or to 25
foot-pounds of torque.

P O S I T I O N

T H E   U N I T

IMPORTANT NOTE: On base units, the top
drawer has a control cable that needs to be
disconnected before removing this drawer.
Refer to illustration 3 below for placement and
how to disconnect this fitting. 

The drawers should be placed aside until you
are ready for installation of the panels.
Remove the decorative top and side molding
pieces and the kickplate/grille.

IMPORTANT NOTE: If two Integrated units are
installed closer than 2" (51) to one another, it is
necessary to use the Sub-Zero dual installation
heater kit. Refer to Dual Installations on page
17 for additional information. The heater plate
from this kit must be attached to the left side
exterior of the right hand unit before the units
are slid into position.

I N T E G R AT E D  

I N S T A L L A T I O N   I N S T R U C T I O N S

Always wear safety glasses and use other
necessary protective devices or apparel
when installing or working with anchors.

Anchors are not recommended for use in
lightweight masonry material such as
block or brick, or for use in new concrete
which has not had sufficient time to cure.
The use of core drills is not recommended
to drill holes for the anchors.

Illus. 3

Before moving the Integrated unit into
position, secure the door closed and
remove the drawers.

O P T I O N A L
C O M P O N E N T S

Optional installa-
tion components
are available
through your
Sub-Zero dealer.
You can also visit
our website at
subzero.com. For
questions relative
to the installation,
call Sub-Zero at
800-222-7820.

Содержание 700BC

Страница 1: ...INSTALLATION INSTRUCTIONS I N T E G R A T E D R E F R I G E R A T I O N ...

Страница 2: ...s informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed C O N T E N T S Installation Recommendations 3 Installation Specifications 4 Installation Instructions 7 Installation Checklist 18 Service...

Страница 3: ...process it is recommended that you read this entire Installation Instructions book There are key details that you should take special care to observe during the installation By reading these instructions carefully you will make the installation process easier problem free and most importantly safe Any questions or problems about the installation should be directed to your Sub Zero dealer or the Su...

Страница 4: ...ING FORWARD 41 2 114 21 2 64 151 2 394 3 4 19 3 76 1 4 6 13 330 9 229 ANTI TIP BRACKET LOCATE WATER LINE REAR ENTRY WITHIN SHADED AREA LOCATE ELECTRICAL WITHIN SHADED AREA ORIENT GROUND PRONG TO RIGHT AS SHOWN PLACEMENT OF THE ANTI TIP BRACKET SHOULD BE 24 610 FROM THE FRONT OF THE UNIT WITHOUT PANELS TO THE BACK OF THE ANTI TIP BRACKET I N S T A L L A T I O N Models 700TR 700TF I and 700TC I Mode...

Страница 5: ... 131 2 343 18 457 ANTI TIP BRACKET 18 457 6 152 TOP VIEW TOP VIEW SIDE VIEW FRONT VIEW WATER LINE SIDE ENTRY LOCATION ANTI TIP BRACKET 21 2 64 20 508 3 4 19 3 76 171 2 445 131 2 343 ANTI TIP BRACKET NOTE ANTI TIP BRACKET MUST BE INSTALLED TO PREVENT UNIT FROM TIPPING FORWARD 41 2 114 1 4 6 LOCATE WATER LINE REAR ENTRY WITHIN SHADED AREA LOCATE ELECTRICAL WITHIN SHADED AREA ORIENT GROUND PRONG TO R...

Страница 6: ...STALLED TO PREVENT UNIT FROM TIPPING FORWARD 41 2 114 21 2 64 151 2 394 3 4 19 3 76 1 4 6 13 330 9 229 ANTI TIP BRACKET LOCATE WATER LINE REAR ENTRY WITHIN SHADED AREA LOCATE ELECTRICAL WITHIN SHADED AREA ORIENT GROUND PRONG TO RIGHT AS SHOWN I N S T A L L A T I O N Models 700BR 700BF I and 700BC I Models without an ice maker will not require the water line connection O V E R A L L D I M E N S I O...

Страница 7: ...use water supply Use an easily accessible shut off valve between the water supply and the unit This shut off valve should not be installed behind the unit Do not use self piercing valves A saddle valve kit part 4200880 is available from your Sub Zero dealer The Installation illustrations on pages 4 6 show the precise placement of the water line When routing through the side walls you must place th...

Страница 8: ...t attaching to a side wall or you are installing two Integrated units together you must remove the clips before moving the unit into place After removing the clips replace the screws in the holes and discard the clips Optional components are necessary for anchoring two Integrated units together Refer to Dual Installations on page 17 Optional installation components are available through your Sub Z...

Страница 9: ...ure that the screws hold tight Refer to illustration 1 below C O N C R E T E F L O O R A P P L I C AT I O N S Use the two 3 8 x 33 4 concrete wedge anchors two 12 x 21 2 wood screws and two 1 4 flat washers provided Be sure that the anchors and screws hold tight Refer to illustration 2 below IMPORTANT NOTE In some installations the subflooring or finished floor may require angling the wood screws ...

Страница 10: ...ide molding pieces and the kickplate grille IMPORTANT NOTE If two Integrated units are installed closer than 2 51 to one another it is necessary to use the Sub Zero dual installation heater kit Refer to Dual Installations on page 17 for additional information The heater plate from this kit must be attached to the left side exterior of the right hand unit before the units are slid into position INT...

Страница 11: ...T R U C T I O N S CO LDE R WA RM ER REF RIG ERA TO R FRE EZE R CO LDE R WA RM ER ICE ON O FF ON O FF UN IT ON O FF Unit On Off Unit On Off Shut off the power to the electrical outlet Before moving the Integrated unit into position tape down the water supply line for the ice maker so it will stay in place as you move the unit Refer to the Installation illustration for your unit on pages 4 6 for pla...

Страница 12: ...oil base high gloss enamel paint INTEGRATED I N S TA L L AT I O N I N S T R U C T I O N S LEVEL T H E U N I T Level the Integrated unit by turning the front leveling legs clockwise to raise the unit or counterclockwise to lower it To assist you in adjusting the front leveling legs up or down use a standard screwdriver blade and place it in the front leveling leg as shown in illustration 6 below Th...

Страница 13: ...e quick connect water valve and PEX tubing are located on the right hand side of the unit towards the bottom Follow these instructions to connect the ice maker water line Attach the union fitting to the copper house water supply line Pull the coiled gray PEX tubing with a red cap and captured metal nut toward the house water supply line Remove and discard the red cap then attach the tubing to the ...

Страница 14: ... E N T S Door and drawer panels must be a minimum of 5 8 16 thick The door panel cannot exceed 40 lbs 18 kg and each drawer panel must not exceed 12 lbs 5 kg for 27 686 wide units For 36 914 wide units the door panel weight limit is 53 lbs 24 kg and 16 lbs 7 kg for each drawer panel KICKPLATE GRILLE I N S TA L L AT I O N Once your Integrated unit is secured the kickplate grille can be installed Th...

Страница 15: ...verall size of the panel shown in illustra tion 13 is the minimum size necessary to cover the door of the unit The exact measurements of your door panel may vary depending on the particular installation you are following Once you have located the proper position for the bracket mark the pilot holes remove the template and drill pilot holes for mounting the bracket It is best to start with a few ho...

Страница 16: ... drawer panel must not exceed 12 lbs 5 kg for 27 686 wide units For 36 914 wide units the door panel weight limit is 53 lbs 24 kg and 16 lbs 7 kg for each drawer panel PANEL I N S TA L L AT I O N Before attaching the door panel to the door remove the outer screws from each of the three mounting positions along the hinge side of the door Unscrew the three remaining screws in the center of each moun...

Страница 17: ... O N S When two Integrated units are installed closer than 2 51 to one another it is necessary to use the Sub Zero dual installation heater kit BBDUAL or TTDUAL The heater plate from this kit must be attached to the left side exterior of the right hand unit before the units are slid into position Contact your Sub Zero dealer for the proper components and installation instructions For questions rel...

Страница 18: ... S T Has the anti tip bracket been installed properly and is it making contact with the unit Is the unit level Are all leveling legs making contact with the floor Is the power cord plugged into a properly grounded 3 prong outlet which has been installed in accordance with all applicable electrical codes Is the water supply connected for units with an automatic ice maker Have you checked for leaks ...

Страница 19: ...he cabinet to the left of the upper drawer 19 If you are storing or disposing of your old refrigerator or freezer please do it safely Remove the doors or tightly secure the doors closed Child entrapment accidents can be tragic C O N TA C T I N F O R M AT I O N Sub Zero Customer Service 800 222 7820 Website subzero com SERVICE I N F O R M AT I O N The information and images in this book are the cop...

Страница 20: ...7 0 0 2 1 2 8 6 2 0 0 6 S U B Z E RO F R E E Z E R C O M PA N Y I N C P O B OX 4 4 1 3 0 M A D I S O N W I 5 3 7 4 4 4 1 3 0 8 0 0 2 2 2 7 8 2 0 S U B Z E RO C O M ...

Отзывы: