background image

Planning Information

Undercounter Model 245

Dimensions in parentheses are in
millimeters unless otherwise specified.

4

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, finished rough opening
dimensions and installation specifics.

The Model 245 lower hinge extends out

from the side of the unit in the area of the kick-
plate. When the unit is installed tightly against a
full-depth panel or cabinet, there can be inter-
ference. Refer to the full-scale illustration on
page 6.

For Model 245 with automatic ice maker,

rough in the water supply line. Connect a 

1

/

4

"

OD copper line to the house supply, being sure
to use an easily accessible shut off valve
between the supply and the unit.

Do not use self-piercing valves. A saddle

valve kit (4200880) is available from your
Sub-Zero dealer. To obtain local dealer informa-
tion, visit the Locator section of our website,
subzero.com.

A line filter is required when water condi-

tions have a high sediment content. The ice
maker operates on water pressure of 20 psi
(1.4 bar) to 100 psi (6.9 bar). In some cases a
reverse osmosis water filter system may not be
able to maintain the minimum water pressure
consistently.

A 115 V AC, 60 Hz, 15 amp fused electrical

supply is required. It is recommended that a
separate circuit, serving only this appliance, be
provided.

All Undercounter models are equipped with a

power supply cord with a 3-prong grounding
plug which must be plugged into a mating
3-prong grounding type wall receptacle. Locate
electrical within the shaded area shown in the
illustration on page 3.

You must follow all National Electrical Code

regulations. In addition, be aware of local codes
and ordinances when installing your service.

Refer to the Undercounter Installation

Instructions packed with the appliance, which
provides step-by-step procedures for making
sure the unit is installed properly.

Содержание 245

Страница 1: ...en you apply custom panels Automatic ice maker Stationary glass shelves Adjustable refrigera tor control Serial and model number plate Interchangeable door hinge Front venting with removable kickplate Removable ice bucket Interior freezer light Stationary door shelves M O D E L 2 4 5 Undercounter refrigerator freezer combination unit 24 610 depth true design for a complete built in look Door accep...

Страница 2: ... 864 Door Swing Clearance 2513 16 656 Electrical Requirements 115 V AC 60 Hz 15 amp circuit Annual Energy Usage 444 kWh 41 based on 9 06 cents per kilowatt hour Shipping Weight 139 lbs 63 kg Special Note Door accepts custom wood panels or panels are available as sales accessories Specifications are subject to change without notice O V E R A L L D I M E N S I O N S O P T I O N A L D O O R P A N E L...

Страница 3: ...pening Height 341 2 876 Finished Rough Opening Depth 24 610 Location of Electrical Within shaded area front view Location of Water Supply Within shaded area top view See Installation Instructions shipped with unit for detailed specifications 341 2 876 ROUGH OPENING HEIGHT 24 610 ROUGH OPENING WIDTH 1 25 7 178 7 178 E 2 51 24 610 ROUGH OPENING DEPTH TOP VIEW FRONT VIEW 12 305 WATER SUPPLY LOCATION ...

Страница 4: ...cal dealer informa tion visit the Locator section of our website subzero com A line filter is required when water condi tions have a high sediment content The ice maker operates on water pressure of 20 psi 1 4 bar to 100 psi 6 9 bar In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently A 115 V AC 60 Hz 15 amp fused electrical supply...

Страница 5: ...tends out from the side of the unit in the area of the kickplate When the unit is installed tightly against a full depth panel or cabinet there can be interference Refer to the full scale illustration on pge 6 The overlay door panel design application is not available for the Model 245 IMPORTANT NOTE The weight of the panel cannot exceed 20 lbs 9 kg F R A M E D P A N E L D I M E N S I O N S Door P...

Страница 6: ... Dimensions in parentheses are in millimeters unless otherwise specified 6 233 4 603 TO BACK OF UNIT 237 8 606 WIDTH OF UNIT DOOR TOP VIEW BOTTOM HINGE EXTENDS 1 4 6 FROM SIDE OF UNIT UP TO 31 2 89 FROM FLOOR M O D E L 2 4 5 L O W E R H I N G E ...