readily apparent. The front-panel LEDs will 
continue to display the DC power status of 
pins 2 and 3. But whether or not either or 
both LEDs are lit, the Model 45 will never 
apply 200 ohm terminations to pins 2 or 
3. For the hybrid circuits to remain stable 
termination impedances must be provided 
by the connected circuits. If these are not 
present one might find the hybrid circuits 
generating very unpleasant audible noise. 
This condition, caused by the 2-wire out-
put circuitry being in an “unloaded” state, 
will not damage the Model 45’s circuitry. 
However, without the auto terminate func-
tion a disconnected cable or other real-
world wiring problem could present users 
with a rude surprise!

In conclusion, it’s important that technical 
personnel working with the Model 45 be 
informed when the auto termination func-
tion has been disabled. They will then be 
aware of the potential noise issues and be 
ready to make corrections should a prob-
lem arise.

4-Wire Mute During Auto Null

Normally, the 4-wire outputs are muted 
whenever the auto null process is taking 
place. This ensures that the test tones 
generated as part of the nulling process 
will not be heard by users of the signals 
associated with the 4-wire outputs. For 
special applications configuration DIP 
switch 5 allows the automatic muting 
mode to be disabled. This mode is pro-
vided primarily for use by factory person-
nel or during demonstration use. During 
normal operation switch 5 should remain 
in its off (down) position. When switch 5 is 
in its on (up) position 4-wire muting dur-
ing auto null will not take place. While not 
appropriate during actual Model 45 use, it 

is interesting to “hear” the nulling process 
take place. But unless there’s a really good 
reason, configuration DIP switch 5 should 
always remain in its off (down) position.

Technical Notes

Software Version Display

A special Model 45 power-up sequence  
allows the unit’s software version number 
to be displayed. This is useful when work-
ing with factory personnel on application 
support and troubleshooting situations. The 
five “from” 4-wire LEDs are used to display 
the major release number with a range of 
1 through 5. The five LEDs associated with 
“to” 4-wire channel 1 are used to display 
the release sub-number which ranges from 
1 through 5. Refer to Figure 8 for a detailed 
view of the LEDs and the corresponding 
software version numbering scheme. The 
Model 45’s initial software release is ver-
sion 1.1 which is represented by the bot-
tom LED of each column being lit.

To display the Model 45’s software version 
is very simple. From the powered-down 
state, press and hold the auto null button. 
While continuing to press the auto null but-
ton, apply power either by connecting an 
external 24 volt DC power source or a pow-
ered intercom circuit. The normal power-up 
sequence will not occur but instead one 
LED in the status column will be lit and one 
LED in the column associated with “from” 
4-wire channel 1 will also be lit. As previ-
ously described, these two LEDs represent 
the unit’s current software version. After the 
software version number has been “read” 
the auto null button can be released. At this 
time the unit will begin its normal power-up 
sequence.

Содержание M45 Interface

Страница 1: ...09 by Studio Technologies Inc all rights reserved www studio tech com 50216 0309 Issue Preliminary 2 User Guide Issue Preliminary 2 March 2009 This User Guide is applicable for serial numbers M45 0015...

Страница 2: ...This page intentionally left blank...

Страница 3: ...ents Introduction 5 Installation 10 Configuration 16 Operation 19 Technical Notes 24 Specifications 27 Appendix A Interfacing with RTS Matrix Intercom Systems 28 Appendix B Interfacing with Riedel Art...

Страница 4: ...Issue Preliminary 2 March 2009 Model 45 User Guide Page 4 Studio Technologies Inc This page intentionally left blank...

Страница 5: ...gned so that full isolation from the connected party line circuit is maintained Figure 2 Model 45 Back Panel Figure 1 Model 45 Front Panel The connected party line intercom circuit can also provide th...

Страница 6: ...ire interface is its ability to create a fully functioning 2 wire party line intercom cir cuit supplying the required DC power and 200 ohm AC terminations Referred to as the Model 45 s 2 wire PL power...

Страница 7: ...tton switch digital circuitry adjusts the analog hybrids to achieve their maximum return loss The nulling process takes approximately 12 seconds for each interface channel And it s important to highli...

Страница 8: ...being added to the 2 wire connection In addition the impedance characteristics of the interface s DC powered wet channel was tailored to be essentially identical to that of the unpowered dry channel T...

Страница 9: ...standard 19 inch rack enclosure Design Philosophy While the bits and pieces that make up the Model 45 have been described in con ventional terms the real strength of the unit rests in the way it integ...

Страница 10: ...on In this section you will be preparing the Model 45 for use Since the standard unit is housed in a self contained enclosure getting it ready for use in portable appli cations requires only making a...

Страница 11: ...mount front panel begin the process by remov ing the five screws that hold the standard throw down front panel to the Model 45 s chassis Using a Phillips screw driver remove the 4 40 flat head Phillip...

Страница 12: ...rcuitry is balanced capacitor coupled transformer isolated and has an impedance of 13 k ohms The line inputs are optimized for signals that have a nominal level of 4 dBu Audio sources are connected to...

Страница 13: ...nel party line intercom circuit This type of circuit typically has positive 28 to 32 volts DC on pin 2 and common on pin 1 The Model 45 s 2 wire party line interface can also serve as an intercom powe...

Страница 14: ...tly interconnected with two Clear Com intercom circuits However power for the connected devices must be provided by ex ternal power sources The Model 45 s ability to supply intercom power will not be...

Страница 15: ...s DC with a re quired current draw of 175 milliamperes Note that for the Model 45 to be powered by the connected 2 wire intercom circuit configuration DIP switch 1 must be in its on up position Please...

Страница 16: ...views Using the Connected 2 Wire Party Line Circuit as the Model 45 s Power Source Configuration DIP switch 1 is used to select whether or not the connected 2 wire intercom circuit can be used to prov...

Страница 17: ...r or not the Model 45 will serve as an intercom power source providing DC power and 200 ohm terminations to the intercom interface When switch 2 is in its off down position the Model 45 will not serve...

Страница 18: ...a cable support both DC power and two channels of audio It s also compatible in situations where all three conductors of a Clear Com single channel intercom circuit are con nected to the Model 45 In...

Страница 19: ...ation sequence before normal operation will begin The LEDs will light sequentially and upon completion the applicable input power LED will light The null settings for the two hybrid circuits are recal...

Страница 20: ...hm termination is expected to be provided elsewhere typically as part of the external power supply and the Mod el 45 s termination is lifted When the Model 45 is Serving as the 2 Wire Intercom Power S...

Страница 21: ...45 contains four 5 segment LED level meters These meters are provided as a support aid during installation con figuration operation and troubleshooting The meters represent the strength of the signals...

Страница 22: ...circuits depend on a single termination being present This termination typically 200 ohms is almost always made at the power supply source But it s possible that another device such as a second activ...

Страница 23: ...dsets during the process In addition to warning users it might be a good time to ask them to mute any active microphones While the automatic mic kill signal will apply to many user devices it may not...

Страница 24: ...ld remain in its off down position When switch 5 is in its on up position 4 wire muting dur ing auto null will not take place While not appropriate during actual Model 45 use it is interesting to hear...

Страница 25: ...d in a typical field shop or repair facility Two Units can be a TW 12B Replacement Two Model 45 units with their 4 wire in terface connectors linked in a crossover fashion can act as a universal 2 wir...

Страница 26: ...vided by the con nected intercom circuits or by way of an external source of 24 volts DC The final step to achieve correct performance is for the auto null function on each Model 45 to be activated Re...

Страница 27: ...brid Loss 40 dB typical at 800 Hz 4 Wire Inputs 2 Type transformer coupled capacitor isolated Impedance 13 k ohms Nominal Level 4 dBu Maximum Level 22 dBu 4 Wire Outputs 2 Type transformer coupled cap...

Страница 28: ...45 User Guide Page 28 Studio Technologies Inc Interfacing RTS Matrix Intercom Systems with the Model 45 Interface Appendix A ADAM Matrix Intercom System Analog Ports to Model 45 Interface RVON I O I...

Страница 29: ...Model 45 User Guide Issue Preliminary 2 March 2009 Studio Technologies Inc Page 29 Interfacing Riedel Artist Matrix Intercom System Analog Ports with the Model 45 Interface Appendix B...

Страница 30: ...Issue Preliminary 2 March 2009 Model 45 User Guide Page 30 Studio Technologies Inc Interfacing Clear Com Matrix Intercom System Analog Ports with the Model 45 Interface Appendix C...

Страница 31: ...Model 45 User Guide Issue Preliminary 2 March 2009 Studio Technologies Inc Page 31 This page intentionally left blank...

Отзывы: