OnAir Digital Mixing Consoles
Configuration 6-73
Document generated: 06.08.14
SW V6.0
6.5.29 gPio
6.5.29.1
general
The GPIO (General Purpose Input/Output) interfaces allow different console
functions being controlled by external control signals as well as generating
control signals depending on the current status of different console functions.
Assignment of functions and control signals to the GPIO connector pins as
well as the behavior of the I/O signals can be freely configured.
Distributed Control
Please note that in I/O sharing applications, a GP input may also control a
function of a neighboring system, and a GP output may be controlled from a
function of a neighboring system without additional wiring; refer to
chapter
6.5.22.1
.
Extra GPIO Frame
Systems with the Compact SCore can consist of the internal plus up to five
external frames. Since SW V2.2, one additional frame with GPIO cards only
may be used.
OnAir 1500/2500
Only 16
internal
GPIOs,
plus
one GPIO card with 16 GPIOs in an optional,
external
D21m I/O frame supported.
6.5.29.2
(Remote) gPio
Remote GPIO is a powerful building brick of the Studer RELINK concept.
In order to make GPIO ready to be used for internal Custom Logic as well as
to allow access to remote systems, GPInputs and GPOutputs have been split
up into
GPInputs/GPOutputs
(physical control inputs/outputs) and
GPInput/
GPOutput functions
.
GPInputs
and
GPOutputs
are handled as producers and consumers in the
sense of I/O Sharing. A
GPInput function
can be compared to a LogicalInput,
where a
GPOutput function
is the counterpart of a LogicalOutput.
GPInput
A GPInput consists of a control input on a D21m GPIO or Ethersound card
and the appropriate input logic.
FixedLabel
Label
Polarity
Activate
Physical
Input
Level
FixedLabel
is defined by the system and remains ‘read only’. It contains a
text specifying the location of the physical input, such as ‘Int, Slot 3, In 2’.
Label
is initialized by the software as ‘GPInput N’ by default. It can be
changed by the user.
For further details on the parameters and the ‘Level’ term, refer to
chapter
6.5.29.2.1
.
The number of GPInputs is configured in the
D21m.xml
file. It has to match
the number of available physical GP inputs in the D21m system.
GPInputs are either
producers
or
net sources
that also may be accessed from
remote systems.
Содержание OnAir 1500
Страница 1: ...Studer OnAir 1500 Digital Mixing Console SW Version 6 0 Operating Instructions ...
Страница 18: ...OnAir 1500 Digital Mixing Console 1 2 Introduction Date printed 06 08 14 SW V6 0 ...
Страница 24: ...OnAir 1500 Digital Mixing Console 1 8 Introduction Date printed 06 08 14 SW V6 0 ...
Страница 26: ...OnAir 1500 Digital Mixing Console 2 2 General Date printed 06 08 14 SW V6 0 ...
Страница 35: ...OnAir 1500 Digital Mixing Console General 2 11 Date printed 06 08 14 SW V6 0 ...
Страница 37: ...OnAir 1500 Digital Mixing Console 3 2 Setup Date printed 06 08 14 SW V6 0 ...
Страница 43: ...OnAir 1500 Digital Mixing Console 3 48 Setup Date printed 06 08 14 SW V6 0 ...
Страница 45: ...OnAir 1500 Digital Mixing Console 4 2 Operating Elements Document generated 06 08 14 SW V6 0 ...
Страница 56: ...OnAir 1500 Digital Mixing Console Operating Elements 4 13 Document generated 06 08 14 SW V6 0 ...
Страница 219: ...OnAir 1500 Digital Mixing Console Operation 5 163 Document generated 06 08 14 SW V6 0 ...
Страница 223: ...OnAir Digital Mixing Consoles 6 4 Configuration Document generated 06 08 14 SW V6 0 ...
Страница 372: ...OnAir Digital Mixing Consoles Configuration 6 153 Document generated 06 08 14 SW V6 0 ...
Страница 374: ...OnAir 1500 Digital Mixing Console 9 2 Networking Document generated 06 08 14 SW V6 0 ...
Страница 386: ...OnAir 1500 Digital Mixing Console 9 14 Networking Document generated 06 08 14 SW V6 0 ...