actual temperatures, a temperature sensor can be connected to the HP-COMPACT.
The compensation through the sensor is –3mV/°C/Cell.
Order Number: CT-35
Dimensions: H x B x T / 58 x 51.5 x 22mm
4.11 Remote control for „Power Sharing“ RPS-01
If the Remote control RPS-01 is installed, the Trimmer
(26) “INPUT LIMIT“ has to be set on the value max..
The HP-COMPACT takes into account the lowest
values set on the inverter and on the Remote control.
The current available at the HP-COMPACT input will be
determined by the power of the connected source
(generator, grid etc...). The potentiometer on the RPS-
01 must be adjusted lower or equal to max. value of the
power source.
For instance if the source is a generator of 2000 Watt, the potentiometer has to be
set at max. 8A. This value is obtained in dividing 2000 Watt by 230V. If the HP-
COMPACT is connected to a power source which is protected by a 6A circuit
breaker, the potentiometer must be set at a max. value of 6A.
Caution: the HP-COMPACT will not limit if an appliance draws more current
than available from the source ! This means that the connected generator will
be over-loaded or that the circuit-breaker before the HP-COMPACT will break.
5 Programming
The HP-COMPACT (except for 60Hz versions) is equipped with a Flash
processor fitted out with EEPROM Memory, which means that even when it is
disconnected from the battery, the parameters that were programmed for the
application remain after a new connection to the battery.
It is possible to reinitialize (RESET) the HP-COMPACT by pressing
simultaneously on the three push buttons 19/20/21 during at least 2 seconds. A
beep will confirm the RESET. The inverter switches off after this operation. It
can be turned on again after the beep. The programmed parameters will
remain.
5.1 Standard
setting
The HP-COMPACT is delivered with the following default settings:
Auxiliary contact: active in case of defect or manual turn off with the LED 10/11/12/13
Battery voltage :
Low voltage
11.6V / 23.2V / 46.4V
Float Charge
13.5V / 27.0V / 54.0V
End of Charge Voltage 14.4V / 28.8V / 57.6V
Equalization
15.6V / 31.2V / 62.4V
Absorption Time :
2 Hours
Equalizing Time :
20 Minutes