Studer Innotec SA
BSP
24
V1.0.3
User Manual
9. Technical data
Supply voltage range
7..85 Vdc
9 mA @ 12 V
5 mA @ 24 V
Supply current
3 mA @ 48 V
Input voltage range
7..85 Vdc
Shunt measurment input range
±195 mV
±500 A (BSP 500)
RMS continous current @ 25 °C
±1200 A (BSP 1200)
±1950 A (BSP 500)
Maximum measurable peak current
±4680 A (BSP 1200)
Voltage measurement accuracy
0.3 %
Current measurement accuracy
0.5 %
Battery capacity
20..20000 Ah
Operating temparture range
-20..55 °C
900 g (BSP 500)
Packed weight
1500 g (BSP 1200)
Displayable values
see Table 6.1
Protection degree
IP20
Conformity
LVD 2006/95/EC, EMC 2004/108/EC, RoHS 2002/95/EC
EN 60950:2005, EN 61000-6-2:2005, EN 61000-6-3:2007
Table 9.1. Specification
Voltage
±0.01 V
±0.01 (1..10)
±0.1 (10..100)
Current (A) and capacity (Ah)
±1(100..9999)
State of charge
±0.1 %
Temperature
±0.1 °C
Time to go
±1'
Table 9.2. Readout resolution