STUDER Innotec SA
AJ
V3.04
14
T
ECHNICAL DATA
Model
AJ 275-12
AJ 350-24
AJ400-48
AJ 500-12
AJ 600-24
AJ 700-48
Inverter
Nominal battery voltage
12Vdc
24Vdc
48Vdc
12Vdc
24Vdc
48Vdc
Input voltage range
10.5 – 16Vdc
21 – 32Vdc
42 – 64Vdc
10.5 – 16Vdc
21 – 32Vdc
42 – 64Vdc
Continous power at 25ºC
200VA
300VA
300VA
400VA
500VA
500VA
Power 30 min. at 25ºC
275VA
350VA
400VA
500VA
600VA
700VA
Power 5 min. at 25ºC
350VA
500VA
600VA
575VA
675VA
900VA
Power 5 sec.at 25ºC
450VA
650VA
1000VA
1000VA
1200VA
1400VA
Maximum asymmetric load
150VA
150VA
200VA
250VA
300VA
300VA
Max. efficiency (%)
93%
94%
94%
93%
94%
94%
Cos φ max.
0.1 – 1 up to
200VA
0.1 – 1 up to
300VA
0.1 – 1 up to
300VA
0.1 – 1 up to
400VA
0.1 – 1 up to
500VA
0.1 – 1 up to
500VA
Detection of the load
2W (only with the solar option –S)
Adjustable: 1
20W
Current of chort-circuit 2 sec. (exit)
2.3Aac (4.6Aac*)
3.2Aac
(6.4Aac*)
4.6Aac (9.2Aac*)
5.2Aac (10Aac*)
5.7Aac
(11.4Aac*)
7Aac (14Aac*)
Output voltage
Sine wave 230Vac (120Vac*) ±5%
Frequency
50Hz (60Hz*) ±0.05% (crystal controlled)
Distortion THD (resistive load)
< 5% (at Pnom. & Uin nom.)
Consumption Stand-by
0.3W**
0.5W**
1.1W**
0.4W
0.6W
1.5W
Consumption „ON“ no load
2.4W
3.5W
5.2W
4.6W
7.2W
12W
Overheat protection (±5ºC)
Shut down at 75ºC, Auto-restart at 70ºC
Overload and short circuit
protection
Automatic disconnection with 2 restart attempts
Reverse polarity protection by
internal fuse
60A
40A
25A
120A
90A
60A
Deep discharge battery protection
Shut off at 0.87 x Unom, Automatic restart at Unom.
Max. battery voltage
Shut off at >1.33 x Unom, Automatic restart at < Umax
Acoustic alarm
Before low battery or overheating disconnection
General data
Weight
2.4 kg
2.6 kg
4.5 kg
Dimensions hxwxl (mm)
142x163x84
142x240x84
Protection index IP
IP 30 conforms to DIN 40050
Certification ECE-R 10 (E24)
●
●
Not available
●
●
Not available
EC confirmity
Low Voltage Directive (LVD) 2014/35/EU - EN 50178:1997 - EN 62109-1:2010
Electromagnetic Compliance (EMC) Directive 2014/30/EU - EN 61000-6-2:2005- EN 61000-6-4:2007/A1:2011
Operating temperature
-20ºC up to +50ºC
Relative humidity in operation
95% without condensation
Ventilation forced
From 45ºC ±5ºC
Acoustic level
< 45 dB (with ventilation)
Warranty
5 years
Approximate correction of Pnom
-1.5%/ºC as from +25ºC
Recommended battery capacity
> 5 x Pnom/Unom (recommended value in Ah)
Length cables (Battery/left AC)
1.2m /1m
1.5m / 1m
Options
AJ 275-12
AJ 350-24
AJ400-48
AJ 500-12
AJ 600-24
AJ 700-48
Solar
regulator
(PWM)
Voltage max
25Vdc
45Vdc
90Vdc
25 Vdc
45Vdc
90Vdc
Current max.
10Adc
15Adc
Principle
3 floating stages (I/U/UO)
Absorption
voltage
14.4Vdc
28.8Vdc
57.6Vdc
14.4Vdc
28.8Vdc
57.6Vdc
Floating voltage
13.6Vdc
27.2Vdc
54.4Vdc
13.6Vdc
27.2Vdc
54.4Vdc
Plug for remote control (RCM)
●
●
●
●
●
●