![Stübbe 6014 Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/stubbe-0/6014-series/6014-series_operating-manual_1386397005.webp)
Layout and Function
3
Layout and Function
3.1
Name plate
6014 C 1,5 FKM MS
G1/8 PN 0-16bar
24V
50 Hz
8W
00450000
W14UN
1
2
3
4
5
6
7
8
Fig. 1
Name plate (example)
1
Pipework connection / rated pressure
2
Type
3
Mode of operation
4
Rated width
5
Seal material
6
housing material
7
ID number
8
Voltage / frequency / power
Device types
•
Type 6014
3.2
Description
The
fi
tting is a solenoid valve. The
fi
tting is used as a pilot valve
for direct attachment to externally-controlled pneumatic drives.
The
fi
tting consists of a solenoid drive and a housing with a
banjo screw. The
fi
tting is connected to the control air port of
the pneumatic drive. The
fi
tting is
fi
tted with manual actuation.
•
Mounting position:
–
any
–
It is preferably installed with the magnetic coil facing
upwards.
–
The magnetic coil can be rotated through 90° (if
installed in a block it can be rotated through 180°)
•
The direction of
fl
ow is speci
fi
ed
3.3
Assembly
1
2
3
4
5
Fig. 2
Assembly
1
nut
2
Magnetic coil
3
Device plug
4
Fitting housing
5
Pipework connection
3.4
Direction of flow
Direction of
fl
ow from P to A
A
P
Fig. 3
Direction of
fl
ow (example)
301 302
BA-2017.10.18 EN
type 6014
5