Stübbe 6014 Series Скачать руководство пользователя страница 5

Layout and Function

3

Layout and Function

3.1

Name plate

6014  C  1,5  FKM  MS
G1/8  PN 0-16bar
24V 

   50 Hz 

8W

00450000

W14UN

1

2

3

4

5

6

7

8

Fig. 1

Name plate (example)

1

Pipework connection / rated pressure

2

Type

3

Mode of operation

4

Rated width

5

Seal material

6

housing material

7

ID number

8

Voltage / frequency / power

Device types

Type 6014

3.2

Description

The

fi

tting is a solenoid valve. The

fi

tting is used as a pilot valve

for direct attachment to externally-controlled pneumatic drives.
The

fi

tting consists of a solenoid drive and a housing with a

banjo screw. The

fi

tting is connected to the control air port of

the pneumatic drive. The

fi

tting is

fi

tted with manual actuation.

Mounting position:

any

It is preferably installed with the magnetic coil facing
upwards.

The magnetic coil can be rotated through 90° (if
installed in a block it can be rotated through 180°)

The direction of

fl

ow is speci

fi

ed

(

3.4 Direction of

fl

ow,

Page 5).

3.3

Assembly

1
2

3

4

5

Fig. 2

Assembly

1

nut

2

Magnetic coil

3

Device plug

4

Fitting housing

5

Pipework connection

3.4

Direction of flow

Direction of

fl

ow from P to A

A

P

Fig. 3

Direction of

fl

ow (example)

301 302

BA-2017.10.18 EN

type 6014

5

Содержание 6014 Series

Страница 1: ...N Print No 301 302 TR MA DE Rev001 ASV St bbe GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact asv stuebbe de Internet www asv stuebbe co...

Страница 2: ...eumatic valve 7 5 3 Connect fitting to electrical system 7 6 Operation 8 6 1 Commissioning 8 6 2 Manual operation 8 7 Maintenance 8 7 1 Servicing 8 7 2 Maintenance 8 7 2 1 Removing fitting 9 7 3 Repla...

Страница 3: ...w this manual and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Type 6014 data sheet Technical data and conditions of operat...

Страница 4: ...pair information before they start any work Organize responsibilities areas of competence and the supervision of personnel The following work should be carried out by specialist tech nicians only Inst...

Страница 5: ...es The fitting consists of a solenoid drive and a housing with a banjo screw The fitting is connected to the control air port of the pneumatic drive The fitting is fitted with manual actuation Mountin...

Страница 6: ...ons Data sheet 4 3 Storage NOTE Material damage due to inappropriate storage Store the fitting properly Make sure the storage room meets the following condi tions Dry Frost free Vibration free Not in...

Страница 7: ...fitting NOTE Material damage from incorrect installation of fitting Use suitable tools Comply with the manufacturer s instructions regarding installation of the pneumatic valve 1 2 3 Fig 4 Installing...

Страница 8: ...arrying out any work on the fitting 7 1 Servicing 1 Visual and function check every three months Normal operating conditions unchanged No leaks No unusual operating noises or vibrations 2 Clean the fi...

Страница 9: ...ng if required Dead space in the fitting may still contain medium 7 3 Replacement parts and return 1 Have the following information ready to hand when order ing spare parts Type plate Fitting type ID...

Страница 10: ...Install fitting in accordance with direction of flow 3 4 Direction of flow Page 5 Valve does not close Plunger disabled Change fitting Connection voltage is cut or insufficient Check supply voltage C...

Страница 11: ...9 mm across flats 5 Tab 4 Tightening torques 9 2 Circuit diagram 2 A 1 P 3 R Fig 6 NC circuit diagram closed when de energized 9 3 Plug assignment DIN EN 175301 803 plug socket The polarity of the con...