Stübbe 6014 Series Скачать руководство пользователя страница 11

Appendix

9

Appendix

9.1

Technical specifications

Technical data (

Data sheet).

9.1.1

Working pressure

Operating pressure (

Data sheet).

9.1.2

Pressure and temperature limits

Pressure and temperature limits (

Data sheet).

9.1.3

Tightening torques

Description

Size

Tightening torque [Nm]

Screw

19 mm
across

fl

ats

5

Tab. 4

Tightening torques

9.2

Circuit diagram

2(A)

1(P) 3(R)

Fig. 6

NC circuit diagram (closed when de-energized)

9.3

Plug assignment

DIN EN 175301-803 plug socket. The polarity of the con-
nections (1,3) has no effect on operation.
For device plugs with LED: Polarity is in accordance with
the printed legend on the connection circuit board.

1

2
3

Fig. 7

Connector plug

1

control voltage

2

Ground conductor connection

3

control voltage

301 302

BA-2017.10.18 EN

type 6014

11

Содержание 6014 Series

Страница 1: ...N Print No 301 302 TR MA DE Rev001 ASV St bbe GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact asv stuebbe de Internet www asv stuebbe co...

Страница 2: ...eumatic valve 7 5 3 Connect fitting to electrical system 7 6 Operation 8 6 1 Commissioning 8 6 2 Manual operation 8 7 Maintenance 8 7 1 Servicing 8 7 2 Maintenance 8 7 2 1 Removing fitting 9 7 3 Repla...

Страница 3: ...w this manual and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Type 6014 data sheet Technical data and conditions of operat...

Страница 4: ...pair information before they start any work Organize responsibilities areas of competence and the supervision of personnel The following work should be carried out by specialist tech nicians only Inst...

Страница 5: ...es The fitting consists of a solenoid drive and a housing with a banjo screw The fitting is connected to the control air port of the pneumatic drive The fitting is fitted with manual actuation Mountin...

Страница 6: ...ons Data sheet 4 3 Storage NOTE Material damage due to inappropriate storage Store the fitting properly Make sure the storage room meets the following condi tions Dry Frost free Vibration free Not in...

Страница 7: ...fitting NOTE Material damage from incorrect installation of fitting Use suitable tools Comply with the manufacturer s instructions regarding installation of the pneumatic valve 1 2 3 Fig 4 Installing...

Страница 8: ...arrying out any work on the fitting 7 1 Servicing 1 Visual and function check every three months Normal operating conditions unchanged No leaks No unusual operating noises or vibrations 2 Clean the fi...

Страница 9: ...ng if required Dead space in the fitting may still contain medium 7 3 Replacement parts and return 1 Have the following information ready to hand when order ing spare parts Type plate Fitting type ID...

Страница 10: ...Install fitting in accordance with direction of flow 3 4 Direction of flow Page 5 Valve does not close Plunger disabled Change fitting Connection voltage is cut or insufficient Check supply voltage C...

Страница 11: ...9 mm across flats 5 Tab 4 Tightening torques 9 2 Circuit diagram 2 A 1 P 3 R Fig 6 NC circuit diagram closed when de energized 9 3 Plug assignment DIN EN 175301 803 plug socket The polarity of the con...

Отзывы: