- 3 -

2.13 

Fuses:

  The power cord must be sourced and supplied by the installer.  Cable  

 

 

selection and fuse size should be based on the motor full load current and the  

 

 

surrounding conditions (supplied with 250 mm flying   

 

lead for local requirements).

2.14 

Cable Gland Fitting Instructions:

 

To enable correct assembly of the cable gland the  

 

 

‘O’-ring (Fig. 3 item 1) must be placed over the cable   

 

before the clamping insert (Fig. 3 item 2) can be  

 

 tightened.
 

Note: Cable diameter range:- 6.5 mm to 9.5 mm.

1 INSTALLATION

1.11 

Secure pipework:

 Ensure pipework to and from pump is independently  

 

 

supported & clipped to prevent forces being transferred to inlet and outlet  

 

 

branches of pump.

1.12

 DO 

NOT

 install a non-return valve, or devices which contain non- 

 

 

 

return valves, in the suction (inlet) pipework to the pump.  The pump    

 

 

must be free to vent to the supply tank at all times.

1.13

 DO 

NOT

 run against a closed valve for periods longer than 5 minutes.

1.14

 DO 

NOT

 allow the supply cord to contact hot surfaces, including the    

 

 

motor shell, pump body or pipework.  The cod should be safely routed  

 

 

and secured by cable clips.

1.15

 Protection:

 The pump must be located in a dry position, frost free and protected   

 

from freezing, particularly when installed in a loft (not recommended).

2 ELECTRICAL 

INSTALLATION

2.11 

Wiring of connection unit:

WARNING: This appliance must be earthed.

 

The wires in the mains lead are coloured in accordance with the following code:  

 

       Green and Yellow:  Earth 

  Blue:  Neutral 

         Brown:  Live

2.12 

Wiring Diagram:

Fig. 3

2

1

230 VAC/1PH/50Hz SUPPLY

L       N                      E

BR

O

W

N

BLU

E

G

REEN

/YEL

LO

W

RE

D

BLAC

K

CAPACITOR

MOTOR

RED

YELLOW

All models Fig. 2

Содержание PH35

Страница 1: ...his instruction booklet with the owner as it contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products CE compliant product PH35 Pt No 46563 PH45 Pt No 46564 ...

Страница 2: ...cted directly to the mains water supply This product should not be used for the supply of water to more than one dwelling house apartment flat Please read installation details carefully as they are intended to ensure this product provides long trouble free service Failure to install the unit in accordance with the installation instructions will lead to invalidation of the warranty STORAGE If this ...

Страница 3: ...r devices which contain non return valves in the suction inlet pipework to the pump The pump must be free to vent to the supply tank at all times 1 13 DO NOT run against a closed valve for periods longer than 5 minutes 1 14 DO NOT allow the supply cord to contact hot surfaces including the motor shell pump body or pipework The cod should be safely routed and secured by cable clips 1 15 Protection ...

Страница 4: ...lves and vent prime pump head a Loosen priming plug and allow an even flow of water this may take a few seconds b Re seal draining plug nipping tight The pump is now ready to start 4 MAINTENANCE 4 11 No routine maintenance is required but provision should be made for easy access to the pump to allow for repairs due to normal wear and tear Isolate the pump from the electricity supply turn off liqui...

Страница 5: ...se frequency 230 1 50 230 1 50 Enclosure IPX4 IPX4 Type of motor Induction Induction Power consumption 380Watts 540 Watts Full load current 1 6 Amps 2 4 Amps Rating Continuous S1 Continuous S1 Max No Starts per hour 60 60 Mechanical Min inlet head 1 metres 1 metres Max inlet head 10 metres 10 metres Max head closed valve 25 metres 42 metres Max working pressure 600 kPa 6 0 bar 900 kPa 9 0 bar Max ...

Страница 6: ...ation improper use unauthorised repair normal wear and tear and defects which have a negligible effect on the value or operation of the pump Reasonable evidence must be supplied that the pump has been purchased within the applicable guarantee period prior to the date of claim such as proof of purchase or the pump serial number In the event of a claim please telephone Stuart Turner Limited on 0844 ...

Страница 7: ... 7 NOTES ...

Страница 8: ...08 EC BS EN 55014 1 BS EN 55014 2 BS EN 55022 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 1999 519 EC BS EN 62233 2011 65 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFAC...

Отзывы: